High-resolution and high-intensity neutron diffractometer with linear position-sensitive detector

被引:6
|
作者
Lee, CH
Moon, MK [1 ]
Em, VT
Choi, YN
Oh, HS
Nam, UW
机构
[1] Korea Atom Energy Res Inst, Taejon 305600, South Korea
[2] Korea Astron Observ, Taejon 305348, South Korea
关键词
diffractometer; position-sensitive neutron detector; high resolution; high intensity; multi-PSD;
D O I
10.1016/S0168-9002(03)01667-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The characteristics of a neutron diffractometer using a He-3 one-dimensional position-sensitive detector (PSD) with delay line readout, a 200 (length) x 100 (height) mm(2) active window and 2.5 mm spatial resolution have been studied and compared with those of the High-Resolution Powder Diffractometer (HRPD) of KAERI with 32 He-3 conventional tube (circle divide 50 mm) detectors and Soller collimators (10') before detectors. For the sample to PSD distance R = 1200 mm, the PSD subtends 8degrees angle of 2theta and provides the resolution and the peak-to-background ratio close to that for HRPD. Time for scanning (with the same statistics) of a 0-160degrees interval is about 1.6 times longer and the multi-PSD system providing efficiency about 10 times higher than HRPD is proposed. Because of the small angle subtended by the PSD, the parasitic peaks from the sample environment are eliminated and operation without an oscillating radial collimator is possible. Additionally, the proposed diffractometer has an advantage for small samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 50 条
  • [31] EVALUATION OF A LINEAR POSITION-SENSITIVE NEUTRON DETECTOR FOR POWDER SPECTROSCOPY
    CHANG, IP
    NUNES, AC
    AIP CONFERENCE PROCEEDINGS, 1982, (89) : 199 - 201
  • [32] A LARGE POSITION-SENSITIVE NEUTRON DETECTOR
    NETTER, P
    LASSEN, L
    SCHRECK, R
    GEMMEKE, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 165 - 174
  • [33] Fiber multilayered ZnS position-sensitive neutron detector with high detection efficiency
    Satoh, Setsuo
    PHYSICA B-CONDENSED MATTER, 2018, 551 : 401 - 404
  • [34] LINEAR POSITION-SENSITIVE DETECTOR FOR X-RAY SINGLE-CRYSTAL DIFFRACTOMETER
    ROHM, KJ
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 312 (01): : 34 - 34
  • [35] SMALL-ANGLE X-RAY DIFFRACTOMETER WITH A LINEAR POSITION-SENSITIVE DETECTOR
    MOGILEVSKY, LY
    DEMBO, AT
    SVERGUN, DI
    FEIGIN, LA
    KRISTALLOGRAFIYA, 1984, 29 (03): : 587 - 591
  • [36] HIGH-RESOLUTION NEUTRON TIME OF FLIGHT DIFFRACTOMETER
    STEICHELE, E
    ARNOLD, P
    PHYSICS LETTERS A, 1973, A 44 (03) : 165 - 166
  • [37] THE AUSTRALIAN HIGH-RESOLUTION NEUTRON POWDER DIFFRACTOMETER
    HOWARD, CJ
    BALL, CJ
    DAVIS, RL
    ELCOMBE, MM
    AUSTRALIAN JOURNAL OF PHYSICS, 1983, 36 (04): : 507 - 518
  • [38] Intensity optimisation of a high-resolution ToF diffractometer
    Demmel, F
    Bernhardt, P
    Magerl, A
    Steichele, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 459 (1-2): : 265 - 272
  • [39] HIGH RESOLUTION GAMMA CAMERA BASED ON A MULTIWIRE POSITION-SENSITIVE DETECTOR.
    Anisimov, Yu.S.
    Cheremukhina, G.A.
    Chernenko, S.P.
    Ivanov, A.B.
    Matyushevsky, E.A.
    Movchan, S.A.
    Netushilova, Z.
    Peshekhonov, V.D.
    Zenvsky, Yu.V.
    Nuclear instruments and methods in physics research, 1985, A235 (03): : 582 - 588
  • [40] HIGH-RESOLUTION PIXE WITH CRYSTAL SPECTROMETER AND POSITION-SENSITIVE PROPORTIONAL COUNTER
    ISHII, K
    HAMANAKA, H
    MORITA, S
    OHURA, M
    YAMAMOTO, Y
    AWAYA, Y
    VACUUM, 1989, 39 (2-4) : 97 - 100