High-resolution and high-intensity neutron diffractometer with linear position-sensitive detector

被引:6
|
作者
Lee, CH
Moon, MK [1 ]
Em, VT
Choi, YN
Oh, HS
Nam, UW
机构
[1] Korea Atom Energy Res Inst, Taejon 305600, South Korea
[2] Korea Astron Observ, Taejon 305348, South Korea
关键词
diffractometer; position-sensitive neutron detector; high resolution; high intensity; multi-PSD;
D O I
10.1016/S0168-9002(03)01667-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The characteristics of a neutron diffractometer using a He-3 one-dimensional position-sensitive detector (PSD) with delay line readout, a 200 (length) x 100 (height) mm(2) active window and 2.5 mm spatial resolution have been studied and compared with those of the High-Resolution Powder Diffractometer (HRPD) of KAERI with 32 He-3 conventional tube (circle divide 50 mm) detectors and Soller collimators (10') before detectors. For the sample to PSD distance R = 1200 mm, the PSD subtends 8degrees angle of 2theta and provides the resolution and the peak-to-background ratio close to that for HRPD. Time for scanning (with the same statistics) of a 0-160degrees interval is about 1.6 times longer and the multi-PSD system providing efficiency about 10 times higher than HRPD is proposed. Because of the small angle subtended by the PSD, the parasitic peaks from the sample environment are eliminated and operation without an oscillating radial collimator is possible. Additionally, the proposed diffractometer has an advantage for small samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 50 条
  • [21] Position-Sensitive Detector with GaAs photocathode and high time resolution
    de-Bur, Vjacheslav
    Terekhov, Alexander
    Kosolobov, Sergey
    Sheibler, Heinrich
    Beskin, Grigory
    Karpov, Sergey
    Plokhotnichenko, Vladimir
    UNIVERSE AT SUB-SECOND TIMESCALES: HIGH TIME RESOLUTION ASTROPHYSICS, 2008, 984 : 186 - +
  • [22] A HIGH-TIME-RESOLUTION POSITION-SENSITIVE RADIATION DETECTOR
    GAVALIAN, VG
    LORIKIAN, MP
    SHIKHLIAROV, KK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 613 - 614
  • [23] A GUINIER DIFFRACTOMETER WITH A SCANNING POSITION-SENSITIVE DETECTOR
    GOBEL, HE
    ADVANCES IN X-RAY ANALYSIS, 1982, 25 : 315 - 324
  • [24] Position-sensitive neutron detector
    Kuznetsov, AV
    Vakhtin, DN
    Radivojevich, Z
    Alkhazov, ID
    Lyapin, VG
    Trzaska, WH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 372 - 377
  • [25] High Resolution Position Sensitive Neutron Detector (HRPSND)
    Downing, R. G.
    NEUTRON RADIOGRAPHY, 2008, : 616 - 621
  • [26] A Large Area Position-Sensitive Scintillation Neutron Detector For Upgrading SENJU Diffractometer
    Nakamura, T.
    Toh, K.
    Ebine, M.
    Birumachi, A.
    Sakasai, K.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [27] HIGH-INTENSITY, HIGH-RESOLUTION NEUTRON RADIOGRAPHY OF NUCLEAR FUELS
    FOSTER, BE
    SNYDER, SD
    DECARLO, VA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (02): : 536 - &
  • [28] HIGH-RESOLUTION SCINTILLATION HODOSCOPE USING A POSITION-SENSITIVE PHOTOMULTIPLIER
    DITTA, J
    SILLOU, D
    MICHALOWICZ, A
    AZAIEZ, H
    KURODA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 220 (2-3): : 343 - 348
  • [29] HIGH-RESOLUTION POSITION-SENSITIVE DETECTORS USING MICROCHANNEL PLATES
    PARKES, W
    EVANS, KD
    MATHIESON, E
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (01): : 151 - 159
  • [30] HIGH-RESOLUTION VIBRATION MEASUREMENTS USING A POSITION-SENSITIVE PHOTOSENSOR
    GRUNWALD, G
    SCHOTT, H
    SCHMIDT, B
    SENSORS AND ACTUATORS A-PHYSICAL, 1991, 26 (1-3) : 467 - 472