High-resolution and high-intensity neutron diffractometer with linear position-sensitive detector

被引:6
|
作者
Lee, CH
Moon, MK [1 ]
Em, VT
Choi, YN
Oh, HS
Nam, UW
机构
[1] Korea Atom Energy Res Inst, Taejon 305600, South Korea
[2] Korea Astron Observ, Taejon 305348, South Korea
关键词
diffractometer; position-sensitive neutron detector; high resolution; high intensity; multi-PSD;
D O I
10.1016/S0168-9002(03)01667-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The characteristics of a neutron diffractometer using a He-3 one-dimensional position-sensitive detector (PSD) with delay line readout, a 200 (length) x 100 (height) mm(2) active window and 2.5 mm spatial resolution have been studied and compared with those of the High-Resolution Powder Diffractometer (HRPD) of KAERI with 32 He-3 conventional tube (circle divide 50 mm) detectors and Soller collimators (10') before detectors. For the sample to PSD distance R = 1200 mm, the PSD subtends 8degrees angle of 2theta and provides the resolution and the peak-to-background ratio close to that for HRPD. Time for scanning (with the same statistics) of a 0-160degrees interval is about 1.6 times longer and the multi-PSD system providing efficiency about 10 times higher than HRPD is proposed. Because of the small angle subtended by the PSD, the parasitic peaks from the sample environment are eliminated and operation without an oscillating radial collimator is possible. Additionally, the proposed diffractometer has an advantage for small samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 50 条
  • [1] A NEUTRON DIFFRACTOMETER WITH A LINEAR POSITION-SENSITIVE DETECTOR
    PARANJPE, SK
    DANDE, YD
    PRAMANA, 1989, 32 (06) : 793 - 800
  • [2] HIGH-RESOLUTION POSITION-SENSITIVE DETECTOR
    GAO, RS
    ROBERT, WE
    SMITH, GJ
    SMITH, KA
    STEBBINGS, RF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (09): : 1954 - 1956
  • [3] NEUTRON POWDER DIFFRACTOMETER EMPLOYING A LINEAR POSITION-SENSITIVE DETECTOR
    NUNES, AC
    CHANG, IP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (02): : 96 - 96
  • [4] HIGH-RESOLUTION POSITION-SENSITIVE DETECTOR FOR THERMAL-NEUTRONS
    KURZ, R
    MULLER, KD
    SCHELTEN, J
    SZEPESVARY, A
    SCHAFER, W
    WILL, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 78 - 80
  • [5] HIGH-RESOLUTION, POSITION-SENSITIVE DETECTOR FOR ENERGETIC PARTICLE BEAMS
    MARSH, EP
    STRATHMAN, MD
    REED, DA
    MORSE, DH
    PONTAU, AE
    ODOM, RW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 77 (1-4): : 85 - 91
  • [6] High-position-resolution neutron detector using a position-sensitive photomultiplier tube
    Clergeau, JF
    Guérard, B
    Buffet, JC
    Van Esch, P
    ADVANCES IN NEUTRON SCATTERING INSTRUMENTATION, 2002, 4785 : 254 - 261
  • [7] A HIGH-RESOLUTION DETECTOR FOR HIGH-INTENSITY RADIATION
    HALL, WC
    HORTON, BM
    KELLER, JW
    LIEBSON, SH
    NUCLEONICS, 1953, 11 (01): : 49 - 55
  • [8] Concept for a high-resolution, high-intensity tof-diffractometer
    Stuhr, U
    PHYSICA B, 1997, 241 : 224 - 226
  • [9] High-resolution synchrotron X-ray powder diffraction with a linear position-sensitive detector
    Lehmann, M.S.
    Christensen, A.N.
    Nielsen, M.
    Feidenhans'l, R.
    Cox, D.E.
    Journal of Applied Crystallography, 1988, 21 (06): : 905 - 910
  • [10] Concept for a high-resolution, high-intensity tof-diffractometer
    Stuhr, U.
    Physica B: Condensed Matter, 1997, 241-243 : 224 - 226