Insert Position in Three-Component Total Ankle Replacement

被引:61
作者
Barg, Alexej [1 ]
Elsner, Andreas [1 ]
Chuckpaiwong, Bavornrit [1 ]
Hintermann, Beat [1 ]
机构
[1] Kantonsspital Liestal, Clin Orthopaed Surg, CH-4410 Liestal, Switzerland
关键词
Three-Component Total Ankle Prosthesis; Polyethylene Insert Position; Radiographic Assessment; CONSECUTIVE ANKLES; FOLLOW-UP; ARTHROPLASTY; COMPONENT; FUSION;
D O I
10.3113/FAI.2010.0754
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total ankle replacement has become a valuable treatment option for end-stage osteoarthritis. The most recent generation of implants comprises a second interface between the polyethylene insert and the tibial prosthetic component. This may permit a better adaptation of position between the implant components and thereby prevent unphysiological loading of ankle ligaments and reduce polyethylene wear. To date, no available data have evaluated whether the relative position of talar and tibial implant components change over time. Materials and Methods: We assessed the radiographs of 368 ankles that underwent primary arthroplasty with a HINTEGRA (R) (Newdeal SA, Lyon, France / Integra, Plainsboro, NJ) ankle to determine the spatial relationship between talar and tibial components at the time of surgery and during followup. The mean time to final followup was 51.2 months (range 11 to 98). We analyzed the anteroposterior offset as the distance between the center of the tibiotalar joint and the longitudinal axis of the tibia. Results: The mean anteroposterior offset ratio was 0.0 +/- 0.06 (range -0.21 to 0.16), and it remained constant over time. Conclusion: Our data suggest that the latest three-component prosthesis functions similar to the two-component prosthesis, but we believe with an added advantage of allowing an individualized position of the polyethylene insert in response to the individual soft tissue load due to different ankle joint configurations.
引用
收藏
页码:754 / 759
页数:6
相关论文
共 15 条
[1]   Uncemented STAR total ankle prostheses -: Three to eight-year follow-up of fifty-one consecutive ankles [J].
Anderson, T ;
Montgomery, F ;
Carlsson, Å .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07) :1321-1329
[2]   Fracture of the polyethylene component in an ankle arthroplasty: A case report [J].
Assal, M ;
Al-Shaikh, R ;
Reiber, BH ;
Hansen, ST .
FOOT & ANKLE INTERNATIONAL, 2003, 24 (12) :901-903
[3]  
Dahabreh Ziad, 2006, J Foot Ankle Surg, V45, P185, DOI 10.1053/j.jfas.2006.02.007
[4]   Early Failure in Total Ankle Replacements Due to Component Malposition: A Report of Two Cases [J].
Goldberg, Andrew J. ;
Sharp, Bob ;
Cooke, Paul .
FOOT & ANKLE INTERNATIONAL, 2009, 30 (08) :783-787
[5]   The HINTEGRA ankle: Rationale and short-term results of 122 consecutive ankles [J].
Hintermann, B ;
Valderrabano, V ;
Dereymaeker, G ;
Dick, W .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (424) :57-68
[6]   The agility total ankle arthroplasty - Seven to sixteen-year follow-up [J].
Knecht, SI ;
Estin, M ;
Callaghan, JJ ;
Zimmerman, MB ;
Alliman, KJ ;
Alvine, FG ;
Saltzman, CL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06) :1161-1171
[7]  
Knupp M, 2006, ORTHOPADE, V35, P489, DOI 10.1007/s00132-006-0935-9
[8]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[9]   THE AXIS OF ROTATION OF THE ANKLE JOINT [J].
LUNDBERG, A ;
SVENSSON, OK ;
NEMETH, G ;
SELVIK, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (01) :94-99
[10]   Prospective Controlled Trial of STAR Total Ankle Replacement Versus Ankle Fusion: Initial Results [J].
Saltzman, Charles L. ;
Mann, Roger A. ;
Ahrens, Jeanette E. ;
Amendola, Annunziato ;
Anderson, Robert B. ;
Berlet, Gregory C. ;
Brodsky, James W. ;
Chou, Loretta B. ;
Clanton, Thomas O. ;
Deland, Jonathan T. ;
DeOrio, James K. ;
Horton, Greg A. ;
Lee, Thomas H. ;
Mann, Jeffrey A. ;
Nunley, James A. ;
Thordarson, David B. ;
Walling, Arthur K. ;
Wapner, Keith L. ;
Coughlin, Michael J. .
FOOT & ANKLE INTERNATIONAL, 2009, 30 (07) :579-596