Gap filling strategies for 3-D-FBP reconstructions of High-Resolution Research Tomograph scans

被引:19
作者
van Velden, Floris H. P. [1 ,2 ]
Kloet, Reina W. [1 ,2 ]
van Berckel, Bart N. M. [1 ,2 ]
Molthoff, Carla F. M. [1 ,2 ]
Larnmertsma, Adriaan A. [1 ,2 ]
Boellaard, Ronald [1 ,2 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Nucl Med, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, PET Res, NL-1007 MB Amsterdam, Netherlands
关键词
High-Resolution Research Tomograph (HRRT); image reconstruction; missing data estimation; positron emission tomography;
D O I
10.1109/TMI.2008.922702
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The High-Resolution Research Tomograph (HRRT) is a dedicated human brain positron emission tomography scanner. Currently available iterative reconstruction algorithms show bias due to nonnegativity constraints. Consequently, implementation of 3-D filtered backprojection (3-D-FBP) is of interest. To apply 3-D-FBP all missing data including those due to gaps between detector heads need to be estimated. The aim of this study was to evaluate various gap filling strategies for 3-D-FBP reconstructions of HRRT data, such as linear and bilinear interpolation or constraint Fourier space gap filling (confosp). Furthermore, missing planes were estimated using segment 0 image data only (noniterative) or by using reconstructed images based on all previous segments (iterative method). Use of bilinear interpolation showed worst correspondence between reconstructed and true activity concentration, especially for small structures. Moreover, phantom data indicated that use of linear interpolation resulted in artifacts in planes located near the edge of the field-of-view. Use of confosp did not show these artifacts. Iterative estimations of the missing planes for vertical bar segments vertical bar > 0 improved image quality at the cost of more computation time. Therefore, use of confosp for filling sinogram gaps with both iterative and noniterative estimation of missing planes are recommended for quantitative 3-D-FBP of HRRT studies.
引用
收藏
页码:934 / 942
页数:9
相关论文
共 28 条
[1]  
[Anonymous], IEEE NUCL SCI S
[2]   Exact and approximate Fourier rebinning algorithms for the solution of the data truncation problem in 3-D PET [J].
Ben Bouallegue, Faycal ;
Crouzet, Jean-Francois ;
Comtat, Claude ;
Fourcade, Marjolaine ;
Mohammadi, Bijan ;
Mariano-Goulart, Denis .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (07) :1001-1009
[3]   Evaluation of basis function and linear least squares methods for generating parametric blood flow images using 15O-water and positron emission tomography [J].
Boellaard, R ;
Knaapen, P ;
Rijbroek, A ;
Luurtsema, GJJ ;
Lammertsma, AA .
MOLECULAR IMAGING AND BIOLOGY, 2005, 7 (04) :273-285
[4]   Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET [J].
Boellaard, R ;
van Lingen, A ;
van Balen, SCM ;
Hoving, BG ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) :81-89
[5]   PPET: A software tool for kinetic and parametric analyses of dynamic PET studies [J].
Boellaard, Ronald ;
Yaqub, M. ;
Lubberink, M. ;
Lammertsma, A. .
NEUROIMAGE, 2006, 31 :T62-T62
[6]  
Buchert R, 1999, J NUCL MED, V40, P1657
[7]  
Comtat C, 2004, IEEE NUCL SCI CONF R, P3492
[8]   AN ALGORITHM FOR MACHINE CALCULATION OF COMPLEX FOURIER SERIES [J].
COOLEY, JW ;
TUKEY, JW .
MATHEMATICS OF COMPUTATION, 1965, 19 (90) :297-&
[9]   Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scanner [J].
de Jong, Hugo W. A. M. ;
van Velden, Floris H. P. ;
Kloet, Reina W. ;
Buijs, Fred L. ;
Boellaard, Ronald ;
Lammertsma, Adriaan A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (05) :1505-1526
[10]  
DEFRISE M, 1991, CONFERENCE RECORD OF THE 1991 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE, VOLS 1-3, P1919, DOI 10.1109/NSSMIC.1991.259250