Cohort study comparing the diagnostic yields of 2 different EUS fine-needle biopsy needles

被引:34
作者
Abdelfatah, Mohamed M. [1 ]
Grimm, Ian S. [2 ]
Gangarosa, Lisa M. [2 ]
Baron, Todd H. [2 ]
机构
[1] East Carolina Univ, Div Gastroenterol & Hepatol, Greenville, NC USA
[2] Univ N Carolina, Div Gastroenterol & Hepatol, 130 Mason Farm Rd,CB 7080, Chapel Hill, NC 27599 USA
关键词
GUIDED TISSUE ACQUISITION; ENDOSCOPIC ULTRASONOGRAPHY;
D O I
10.1016/j.gie.2017.08.033
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Two second-generation, flexible EUS fine-needle biopsy (FNB) needles have been marketed recently in the United States. Thus far, there have been no comparative studies of the diagnostic yield of these needles. The aim of this study was to compare the diagnostic yield achieved with FNB by using 1 needle during 1 time period and the other needle during a second time period. Methods: Consecutive patients with solid lesions undergoing EUS-FNB by using 1 of two 22-gauge FNB needles (Franseen needle or fork-tip) at 2 different time intervals were included. The final diagnosis was based on positive pathology results. In cases of a negative pathology result, the final diagnosis was based on clinical and imaging follow-up. Results: A total of 194 lesions (97 in each group) were sampled in 179 patients. Rapid on-site evaluation (ROSE) was used in 12% of cases. The overall diagnostic yield was lower in the Franseen needle group compared with the fork-tip needle group (61/97 [63%] vs 75/97 [77%], odds ratio (OR) 2.01, 1.07-3.8; P = .027). Similarly, subanalysis of the yield for solid pancreatic masses demonstrated a lower yield with the Franseen needle (34/53 [64%] vs 40/47 [85%], OR 3.4, 9.1-8.9; P = .017). Multivariate analysis controlling for the number of passes, site, and lesion size did not have any effect on diagnostic yield. There were no adverse events in either group. Conclusion: In this first, large, single-center comparative cohort study of 2 new, second-generation EUS-FNB needles of different design, the diagnostic yield when used primarily without ROSE was high in both groups but was significantly higher when a fork-tip needle was used.
引用
收藏
页码:495 / 500
页数:6
相关论文
共 12 条
[1]   Endoscopic ultrasonography-guided biopsy using a Franseen needle design: Initial assessment [J].
Bang, Ji Young ;
Hebert-Magee, Shantel ;
Hasan, Muhammad K. ;
Navaneethan, Udayakumar ;
Hawes, Robert ;
Varadarajulu, Shyam .
DIGESTIVE ENDOSCOPY, 2017, 29 (03) :338-346
[2]   Initial experience with a novel EUS-guided core biopsy needle (SharkCore): results of a large North American multicenter study [J].
DiMaio, Christopher J. ;
Kolb, Jennifer M. ;
Benias, Petros C. ;
Shah, Hiral ;
Shah, Shashin ;
Haluszka, Oleh ;
Maranki, Jennifer ;
Sharzehi, Kaveh ;
Lam, Eric ;
Gordon, Stuart R. ;
Hyder, Sarah M. ;
Kaimakliotis, Pavlos Z. ;
Allaparthi, Satya B. ;
Gress, Frank G. ;
Sethi, Amrita ;
Shah, Ashish R. ;
Nieto, Jose ;
Kaul, Vivek ;
Kothari, Shivangi ;
Kothari, Truptesh H. ;
Ho, Sammy ;
Izzy, Manhal J. ;
Sharma, Neil R. ;
Watson, Rabindra R. ;
Muthusamy, V. Raman ;
Pleskow, Douglas K. ;
Berzin, Tyler M. ;
Sawhney, Mandeep ;
Aljahdi, Emad ;
Ryou, Marvin ;
Wong, Clarence K. ;
Gupta, Parantap ;
Yang, Dennis ;
Gonzalez, Susana ;
Adler, Douglas G. .
ENDOSCOPY INTERNATIONAL OPEN, 2016, 4 (09) :E974-E979
[3]   EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis [J].
Hewitt, Michael Jonathan ;
McPhail, Mark J. W. ;
Possamai, Lucia ;
Dhar, Ameet ;
Vlavianos, Panagiotis ;
Monahan, Kevin J. .
GASTROINTESTINAL ENDOSCOPY, 2012, 75 (02) :319-331
[4]  
Ishikawa T, SURG ENDOSC
[5]   CURRENT STATUS OF DIAGNOSTIC ENDOSCOPIC ULTRASONOGRAPHY IN THE EVALUATION OF PANCREATIC MASS LESIONS [J].
Itoi, Takao ;
Sofuni, Atsushi ;
Itokawa, Fumihide ;
Irisawa, Atsushi ;
Khor, Christopher J. L. ;
Rerknimitr, Rungsun .
DIGESTIVE ENDOSCOPY, 2011, 23 :17-21
[6]   Novel fork-tip needles versus standard needles for EUS-guided tissue acquisition from solid masses of the upper GI tract: a matched cohort study [J].
Jovani, Manol ;
Abidi, Wasif M. ;
Lee, Linda S. .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2017, 52 (6-7) :784-787
[7]   EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study [J].
Kandel, Pujan ;
Tranesh, Ghassan ;
Nassar, Aziza ;
Bingham, Russell ;
Raimondo, Massimo ;
Woodward, Timothy A. ;
Gomez, Victoria ;
Wallace, Michael B. .
GASTROINTESTINAL ENDOSCOPY, 2016, 84 (06) :1034-1039
[8]  
Khan MA, 2017, ENDOSC INT OPEN, V5, pE363, DOI 10.1055/s-0043-101693
[9]   Novel needle cutting edge geometry for end-cut biopsy [J].
Moore, Jason Z. ;
McLaughlin, Patrick W. ;
Shih, Albert J. .
MEDICAL PHYSICS, 2012, 39 (01) :99-108
[10]   Modeling of the Plane Needle Cutting Edge Rake and Inclination Angles for Biopsy [J].
Moore, Jason Z. ;
Zhang, Qinhe ;
McGill, Carl S. ;
Zheng, Haojun ;
McLaughlin, Patrick W. ;
Shih, Albert J. .
JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (05)