Validity of vertical jump measurement devices

被引:130
作者
Buckthorpe, Matthew [1 ]
Morris, John [1 ]
Folland, Jonathan P. [1 ]
机构
[1] Univ Loughborough, Sch Sport Exercise & Hlth Sci, Loughborough LE11 3TU, Leics, England
关键词
Field tests; force plate; validity; vertical jump height; MECHANICAL-BEHAVIOR; STATISTICAL-METHODS; ASSESSING AGREEMENT; SPORTS-MEDICINE; RELIABILITY; TESTS; PERFORMANCE; HEIGHT;
D O I
10.1080/02640414.2011.624539
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Vertical jump height is thought to provide a valuable index of muscular power, which is an important factor in sports performance and for assessing the mobility and functional capacity of injured or aged individuals. The purpose of the present study was to investigate the criterion validity of four popular devices for measuring vertical jump height. A belt mat, contact mat, portable force plate, and Vertec were compared to a criterion device, a laboratory force plate. Forty participants performed three maximal countermovement jumps on each device in a counterbalanced order, using block randomization. The criterion device presented the highest mean value (50.3 cm). The portable force plate and belt mat devices recorded similar jump height values to the criterion device (within 1 cm). The contact mat and Vertec devices recorded significantly lower values than the criterion device (P < 0.001). The mean difference +/- limits of agreement were: belt mat -0.1 +/- 5.5 cm, contact mat -11.7 +/- 6.4 cm, portable force plate -0.8 +/- 3.9 cm, and Vertec -2.4 +/- 6.6 cm. In conclusion, the portable force plate and belt mat devices provided valid measures of vertical jump height, whereas the Vertec and contact mat devices did not.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 30 条
[1]  
Aragon-Vargas L. F., 2000, Measurement in Physical Education and Exercise Science, V4, P215, DOI 10.1207/S15327841MPEE0404_2
[2]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[3]   ARTHROSCOPY-ASSISTED ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING PATELLAR TENDON SUBSTITUTION - 2-YEAR TO 4-YEAR FOLLOW-YP RESULTS [J].
BACH, BR ;
JONES, GT ;
SWEET, FA ;
HAGER, CA .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (06) :758-767
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   INFLUENCE OF AGING ON THE MECHANICAL-BEHAVIOR OF LEG EXTENSOR MUSCLES [J].
BOSCO, C ;
KOMI, PV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1980, 45 (2-3) :209-219
[6]   POTENTIATION OF THE MECHANICAL-BEHAVIOR OF THE HUMAN SKELETAL-MUSCLE THROUGH PRESTRETCHING [J].
BOSCO, C ;
KOMI, PV .
ACTA PHYSIOLOGICA SCANDINAVICA, 1979, 106 (04) :467-472
[7]   Changes in the Eccentric Phase Contribute to Improved Stretch-Shorten Cycle Performance after Training [J].
Cormie, Prue ;
McGuigan, Michael R. ;
Newton, Robert U. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (09) :1731-1744
[8]   Validity and reliability of the Newtest Powertimer 300-series® testing system [J].
Enoksen, Eystein ;
Tonnessen, Espen ;
Shalfawi, Shaher .
JOURNAL OF SPORTS SCIENCES, 2009, 27 (01) :77-84
[9]   Validity and reliability of methods for testing vertical jumping performance [J].
Hatze, H .
JOURNAL OF APPLIED BIOMECHANICS, 1998, 14 (02) :127-140
[10]   Possibilities and limitations in the biomechanical analysis of countermovement jumps: A methodological study [J].
Kibele, A .
JOURNAL OF APPLIED BIOMECHANICS, 1998, 14 (01) :105-117