Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures

被引:26
作者
Schreiner, Robert S. [1 ]
Rider, Alan R. [1 ]
Myers, John W. [1 ]
Ji, Bingyang [1 ]
Kunselman, Allen R. [2 ]
Myers, John L. [1 ,3 ]
Uendar, Akif [1 ,3 ,4 ]
机构
[1] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Pediat, Hershey, PA 17033 USA
[2] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Hlth Evaluat Sci, Hershey, PA 17033 USA
[3] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Surg, Hershey, PA 17033 USA
[4] Penn State Childrens Hosp, Penn State Milton S Hershey Med Ctr, Penn State Coll Med, Dept Bioengn, Hershey, PA 17033 USA
关键词
D O I
10.1097/MAT.0b013e31816ecfff
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to detect and classify the number and size of gaseous microemboli in a simulated pediatric model of cardiopulmonary bypass. Tests were conducted at five different flow rates (400-1,200 ml/min in 200 ml/min increments), pulsatile versus nonpulsatile perfusion modes, and under normothermic, hypothermic, and deep hypothermic (35 degrees C, 25 degrees C, and 15 degrees C) conditions, yielding 180 total experiments. The circuit was primed with lactated Ringer's solution and filled with heparinized bovine blood. At the beginning of each experiment, 5 ml of air were injected into the venous line via the luer port of the oxygenator. Microemboli were quantified and classified by size for 5 minute segments at three transducer sites: postpump, postoxygenator, and postarterial filter. The purge line of the arterial filter was closed during all experiments. In all but one experiment, 90% of emboli at the postpump site were found to be smaller than 40 mu m. At the postarterial filter site, nearly 99% of the emboli were smaller than 40 mu m. Additionally, increasing microemboli counts were observed when the flow rate was increased and when the temperature was decreased. Lower temperatures, higher flow rates, and pulsatile perfusion were all associated with higher emboli counts. The majority of gaseous microemboli found in the simulated circuit was significantly below 40 mu m; the smallest level detectable by traditional Doppler devices.
引用
收藏
页码:316 / 324
页数:9
相关论文
共 13 条
  • [1] Effects of pulsatile and nonpulsatile perfusion on vital organ recovery in pediatric heart surgery:: A pilot clinical study
    Alkan, Tijen
    Akcevin, Atif
    Uendar, Akif
    Tuerkoglu, Halil
    Paker, Tufan
    Aytac, Aydin
    [J]. ASAIO JOURNAL, 2006, 52 (05) : 530 - 535
  • [2] BUTLER KD, 2000, CARDIOPULMONARY BYPA, P320
  • [3] Cooling gradients and formation of gaseous microemboli with cardiopulmonary bypass: An echocardiographic study
    Geissler, HJ
    Allen, SJ
    Mehlhorn, U
    Davis, KL
    deVivie, ER
    Kurusz, M
    Butler, BD
    [J]. ANNALS OF THORACIC SURGERY, 1997, 64 (01) : 100 - 104
  • [4] An evaluation of the benefits of pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass procedures in pediatric and adult cardiac patients
    Ji, Bingyang
    Uendar, Akif
    [J]. ASAIO JOURNAL, 2006, 52 (04) : 357 - 361
  • [5] Jones Timothy J, 2002, J Extra Corpor Technol, V34, P34
  • [6] Gaseous microemboli sizing in extracorporeal circuits using ultrasound backscatter
    Lynch, John E.
    Pouch, Alison
    Sanders, Randi
    Hinders, Mark
    Rudd, Kevin
    Sevick, John
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (10) : 1661 - 1675
  • [7] A COMPARISON OF THE PERIOPERATIVE NEUROLOGIC EFFECTS OF HYPOTHERMIC CIRCULATORY ARREST VERSUS LOW-FLOW CARDIOPULMONARY BYPASS IN INFANT HEART-SURGERY
    NEWBURGER, JW
    JONAS, RA
    WERNOVSKY, G
    WYPIJ, D
    HICKEY, PR
    KUBAN, KCK
    FARRELL, DM
    HOLMES, GL
    HELMERS, SL
    CONSTANTINOU, J
    CARRAZANA, E
    BARLOW, JK
    WALSH, AZ
    LUCIUS, KC
    SHARE, JC
    WESSEL, DL
    HANLEY, FL
    MAYER, JE
    CASTANEDA, AR
    WARE, JH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (15) : 1057 - 1064
  • [8] Oxygenation strategy and neurologic damage after deep hypothermic circulatory arrest. I. Gaseous microemboli
    Nollert, G
    Nagashima, M
    Bucerius, J
    Shin'oka, T
    Jonas, RA
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 117 (06) : 1166 - 1171
  • [9] Cerebral emboli during cardiac surgery in children
    OBrien, JJ
    Butterworth, J
    Hammon, JW
    Morris, KJ
    Phipps, JM
    Stump, DA
    [J]. ANESTHESIOLOGY, 1997, 87 (05) : 1063 - 1069
  • [10] Embolic Factors Associated with Cardiac Surgery
    Stump, David A.
    [J]. SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 9 (02) : 151 - 152