Heart Failure 3 Implantable cardioverter defibrillators and cardiac resynchronisation therapy

被引:34
作者
Holzmeister, Johannes [1 ]
Leclercq, Christophe [2 ]
机构
[1] Univ Zurich Hosp, Dept Cardiol & Cardiac Surg, CH-8091 Zurich, Switzerland
[2] CHU Pontchaillou, Dept Cardiol & Malad Vasc, Rennes, France
关键词
LEFT-VENTRICULAR DYSSYNCHRONY; LONG-TERM SURVIVAL; CARE-HF TRIAL; RESYNCHRONIZATION THERAPY; SPECKLE-TRACKING; PROPHYLACTIC IMPLANTATION; AUTOMATIC DEFIBRILLATOR; MYOCARDIAL-INFARCTION; SYSTOLIC DYSFUNCTION; DISEASE PROGRESSION;
D O I
10.1016/S0140-6736(11)61228-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantable cardioverter defibrillators and cardiac resynchronisation therapy (CRT) have become standard of care in modern treatment for heart failure. Results from trials have provided ample evidence that CRT, in addition to its proven benefits in patients with symptomatic heart failure (New York Heart Association [NYHA] class III), might also reduce morbidity and mortality in those with mildly symptomatic heart failure (NYHA class II). As a result, the 2010 European Society of Cardiology guidelines now recommend CRT for both patient populations. In this review we summarise and critically assess the landmark randomised clinical trials REVERSE, MADIT-CRT, and RAFT. Furthermore, we discuss the rationale and available evidence for other emerging indications of CRT, including its use in patients with a mildly reduced left ventricular ejection fraction (>35%), in those with a narrow QRS complex (<= 120 ms), and in those with concomitant bradyarrhythmic pacemaker indications. We also focus on patients who do not respond to CRT, and on CRT optimisation.
引用
收藏
页码:722 / 730
页数:9
相关论文
共 84 条
[1]   Rationale and design of a randomized clinical trial to assess the safety and efficacy of frequent optimization of cardiac resynchronization therapy: The Frequent Optimization Study Using the QuickOpt Method (FREEDOM) trial [J].
Abraham, William T. ;
Gras, Daniel ;
Yu, Cheuk Man ;
Guzzo, Lisa ;
Gupta, Manish S. .
AMERICAN HEART JOURNAL, 2010, 159 (06) :944-U1
[2]   Effects of cardiac resynchronization on disease progression in patients with left ventricular systolic dysfunction, an indication for an implantable cardioverter-defibrillator, and mildly symptomatic chronic heart failure [J].
Abraham, WT ;
Young, JB ;
León, AR ;
Adler, S ;
Bank, AJ ;
Hall, SA ;
Lieberman, R ;
Liem, LB ;
O'Connell, JB ;
Schroeder, JS ;
Wheelan, KR .
CIRCULATION, 2004, 110 (18) :2864-2868
[3]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[4]   Long-term effectiveness of cardiac resynchronization therapy in patients with refractory heart failure and "narrow" QRS [J].
Achilli, A ;
Sassara, M ;
Ficili, S ;
Pontillo, D ;
Achilli, P ;
Alessi, C ;
De Spirito, S ;
Guerra, R ;
Patruno, N ;
Serra, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (12) :2117-2124
[5]  
Achtelik M, 2000, PACE, V23, P1741
[6]   Sudden cardiac death: epidemiology and risk factors [J].
Adabag, A. Selcuk ;
Luepker, Russell V. ;
Roger, Veronique L. ;
Gersh, Bernard J. .
NATURE REVIEWS CARDIOLOGY, 2010, 7 (04) :216-225
[7]   Surgically placed left ventricular leads provide similar outcomes to percutaneous leads in patients with failed coronary sinus lead placement [J].
Ailawadi, Gorav ;
LaPar, Damien J. ;
Swenson, Brian R. ;
Maxwell, Cory D. ;
Girotti, Micah E. ;
Bergin, James D. ;
Kern, John A. ;
DiMarco, John P. ;
Mahapatra, Srijoy .
HEART RHYTHM, 2010, 7 (05) :619-625
[8]   Primary prevention of sudden cardiac death in idiopathic dilated cardiomyopathy -: The cardiomyopathy trial (CAT) [J].
Bänsch, D ;
Antz, M ;
Boczor, S ;
Volkmer, M ;
Tebbenjohanns, J ;
Seidl, K ;
Block, M ;
Gietzen, F ;
Berger, J ;
Kuck, KH .
CIRCULATION, 2002, 105 (12) :1453-1458
[9]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[10]   Echocardiographic evaluation of cardiac resynchronization therapy: Ready for routine clinical use? A critical appraisal [J].
Bax, JJ ;
Ansalone, G ;
Breithardt, OA ;
Derumeaux, G ;
Leclercq, C ;
Schalij, MJ ;
Sogaard, P ;
Sutton, MS ;
Nihoyannopoulos, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (01) :1-9