Performance of ICDAS II and fluorescence methods on detection of occlusal caries-An ex vivo study

被引:12
作者
Marczuk-Kolada, Grazyna [1 ]
Luczaj-Cepowicz, Elzbieta [1 ]
Obidzinska, Marta [1 ]
Rozycki, Janusz [2 ]
机构
[1] Med Univ Bialystok, Dept Pedodont, Waszyngtona Str 15a, PL-15297 Bialystok, Poland
[2] Med Univ Bialystok, Dept Radiol, M Curie Sldodowskiej Str 24a, PL-15274 Bialystok, Poland
关键词
Occlusal caries detection; ICDAS II; Fluorescence methods; Cone beam computed tomography; IN-VIVO; VISUAL EXAMINATION; DEVICE; CAMERA; SURFACES; DIAGNODENT; SYSTEM;
D O I
10.1016/j.pdpdt.2019.101609
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The aim of this ex vivo study was to compare the performance of the visual ICDAS II scale and two fluorescence methods (DIAGNOdent Pen and VistaCam iX) in detecting occlusal caries lesions in permanent teeth using cone beam computed tomography (CBCT) as a reference test. Methods: One hundred-sixty molars and premolars were qualified for the study. The visual, the DIAGNOdent Pen and VistaCam iX examinations were carried out by two examiners. The actual extent of the lesions was determined using CBCT. For the three methods, inter- and intra-examiner reproducibility was calculated using intraclass correlation coefficient. The sensitivity, specificity, and accuracy of these methods were compared using the mid-P McNemar test. The level of significance was set at p < 0.05. Results: For all data, intraclass-correlation coefficients (ICC) for intra- and inter-examiner reproducibility were high. With regard to the enamel threshold, the sensitivity and accuracy were significantly higher for VistaCam iX and ICDAS II compared with the DIAGNOdent Pen (p < 0.05). The results obtained with the DIAGNOdentu Pen indicated significantly higher specificity values for the enamel threshold (p < 0.05). The results obtained with the VistaCam iX showed the lowest sensitivity but the significantly highest specificity and accuracy for the dentin threshold (p < 0.05). Conclusions: The ICDAS II is an effective method for detecting early carious lesions, characterized by a higher sensitivity compared with devices using fluorescence. To improve the diagnostic efficiency of the evaluated devices, modifying the cut-off values recommended by the manufacturers should be considered.
引用
收藏
页数:6
相关论文
共 40 条
[1]   Evaluation of a new fluorescence-based device in the detection of incipient occlusal caries lesions [J].
Achilleos, Eva-Eleni ;
Rahiotis, Christos ;
Kakaboura, Afrodite ;
Vougiouklakis, George .
LASERS IN MEDICAL SCIENCE, 2013, 28 (01) :193-201
[2]   A novel LED-based device for occlusal caries detection [J].
Aktan, Ali Murat ;
Cebe, Mehmet Ata ;
Ciftci, Mehmet Ertugrul ;
Karaarslan, Emine Sirin .
LASERS IN MEDICAL SCIENCE, 2012, 27 (06) :1157-1163
[3]   The Effect of Combining Radiographs and DIAGNOdent With Visual Examination on Detection and Treatment Decisions of Noncavitated Occluso-dentinal Caries [J].
Alomari, Q. D. ;
Qudiemat, M. ;
Khalaf, M. E. ;
Al-Tarakemah, Y. .
OPERATIVE DENTISTRY, 2015, 40 (03) :313-321
[4]  
[Anonymous], [No title captured]
[5]  
[Anonymous], [No title captured]
[6]   A systematic review of the performance of a laser fluorescence device for detecting caries [J].
Bader, JD ;
Shugars, DA .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (10) :1413-1426
[7]   Comparison of micro-CT imaging and histology for approximal caries detection [J].
Boca, C. ;
Truyen, B. ;
Henin, L. ;
Schulte, A. G. ;
Stachniss, V. ;
De Clerck, N. ;
Cornelis, J. ;
Bottenberg, P. .
SCIENTIFIC REPORTS, 2017, 7
[8]   Occlusal Caries Extension in Relation to Visual and Radiographic Diagnostic Criteria: Results from a Microcomputed Tomography Study [J].
Buecher, K. ;
Galler, M. ;
Seitz, M. ;
Hickel, R. ;
Kunzelmann, K-H ;
Kuehnisch, J. .
OPERATIVE DENTISTRY, 2015, 40 (03) :255-262
[9]   Clinical diagnosis of fissure caries with conventional and laser-induced fluorescence techniques [J].
Chu, C. H. ;
Lo, E. C. M. ;
You, D. S. H. .
LASERS IN MEDICAL SCIENCE, 2010, 25 (03) :355-362
[10]   In vivo evaluation of laser fluorescence performance using different cut-off limits for occlusal caries detection [J].
Diniz, Michele Baffi ;
Rodrigues, Jonas de Almeida ;
de Paula, Andreia Bolzan ;
Loiola Cordeiro, Rita de Cassia .
LASERS IN MEDICAL SCIENCE, 2009, 24 (03) :295-300