Trace level voltammetric determination of lead and cadmium in sediment pore water by a bismuth-oxychloride particle-multiwalled carbon nanotube composite modified glassy carbon electrode

被引:109
作者
Cerovac, Sandra [1 ]
Guzsvany, Valeria [1 ]
Konya, Zoltan [2 ,3 ]
Ashrafi, Amir M. [4 ,5 ]
Svancara, Ivan [4 ]
Roncevic, Srdan [1 ]
Kukovecz, Akos [2 ,6 ]
Dalmacija, Bozo [1 ]
Vytras, Karel [4 ]
机构
[1] Univ Novi Sad, Fac Sci, Dept Chem Biochem & Environm Protect, Novi Sad 21000, Serbia
[2] Univ Szeged, Dept Appl & Environm Chem, H-6720 Szeged, Hungary
[3] MTA SZTE, React Kinet & Surface Chem Res Grp, H-6720 Szeged, Hungary
[4] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, Pardubice 53210, Czech Republic
[5] MemBrain Sro, Straz Pod Ralskem 47127, Czech Republic
[6] MTA SZTE, Lendulet Porous Nanocomposites Res Grp, H-6720 Szeged, Hungary
基金
匈牙利科学研究基金会;
关键词
Bismuth-oxychloride/multiwalled carbon nanotubes; Bismuth/multiwalled carbon nanotubes; Modified electrodes; Lead and cadmium; Determination; Sediment pore water; ANODIC-STRIPPING VOLTAMMETRY; HEAVY-METAL IONS; FILM ELECTRODE; PLATED CARBON; PASTE ELECTRODE; NEONICOTINOID INSECTICIDES; MERCURY; MICROELECTRODES; CD(II); PB(II);
D O I
10.1016/j.talanta.2014.12.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two multiwalled carbon nanotubes-based composites modified with bismuth and bismuth-oxychloride particles were synthesized and attached to the glassy carbon electrode substrate. The resultant configurations, Bi/MWCNT-GCE and BiOCl/MWNT-GCE, were then characterized with respect to their physicochemical properties and electroanalytical performance in combination with square-wave anodic stripping voltammetry (SWASV). Further, some key experimental conditions and instrumental parameters were optimized; namely: the supporting electrolyte composition, accumulation potential and time, together with the parameters of the SWV-ramp. The respective method with both electrode configurations has then been examined for the trace level determination of Pb2+ and Cd2+ ions and the results compared to those obtained with classical bismuth-film modified GCE. The different intensities of analytical signals obtained at the three electrodes for Pb2+ and Cd2+ vs. the saturated calomel reference electrode had indicated that the nature of the modifiers and the choice of the supporting electrolyte influenced significantly the corresponding stripping signals. The most promising procedure involved the BiOCl/MWCNT-GCE and the acetate buffer (pH 4.0) offering limits of determination of 4.0 mu g L-1 Cd2+ and 1.9 mu g L-1 Pb2+ when accumulating for 120 s at a potential of -.20 V vs. ref. The BiOCl/MWCNT electrode was tested for the determination of target ions in the pore water of a selected sediment sample and the results agreed well with those obtained by graphite furnace atomic absorption spectrometry. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:640 / 649
页数:10
相关论文
共 68 条
[1]  
Ashrafi A.M., 2013, SENSOR ACTUAT B-CHEM, V191, P320
[2]   Bismuth film microelectrodes for heavy metals monitoring by anodic stripping voltammetry [J].
Baldo, MA ;
Daniele, S ;
Bragato, C .
JOURNAL DE PHYSIQUE IV, 2003, 107 :103-106
[3]   Anodic stripping voltammetry at a new type of disposable bismuth-plated carbon paste mini-electrodes [J].
Baldrianova, L. ;
Svancara, I. ;
Sotiropoulos, S. .
ANALYTICA CHIMICA ACTA, 2007, 599 (02) :249-255
[4]   Anodic stripping voltammetry at in situ bismuth-plated carbon and gold microdisc electrodes in variable electrolyte content unstirred solutions [J].
Baldrianova, L. ;
Svancara, I. ;
Economou, A. ;
Sotiropoulos, S. .
ANALYTICA CHIMICA ACTA, 2006, 580 (01) :24-31
[5]   The effect of acetate concentration, solution pH and conductivity on the anodic stripping voltammetry of lead and cadmium ions at in situ bismuth-plated carbon microelectrodes [J].
Baldrianova, L. ;
Agrafiotou, P. ;
Svancara, I. ;
Jannakoudakis, A. D. ;
Sotiropoulos, S. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) :31-36
[6]   Manganese detection in marine sediments:: anodic vs. cathodic stripping voltammetry [J].
Banks, CE ;
Kruusma, J ;
Moore, RR ;
Tomcík, P ;
Peters, J ;
Davis, J ;
Komorsky-Lovric, S ;
Compton, RG .
TALANTA, 2005, 65 (02) :423-429
[7]   Seasonal and depth variability of reduced sulphur species and metal ions in mud-flat pore-waters of the Venice Lagoon [J].
Bertolin, A ;
Mazzocchin, GA ;
Rudello, D ;
Ugo, P .
MARINE CHEMISTRY, 1997, 59 (1-2) :127-140
[8]   CATALYTIC ADSORPTIVE STRIPPING VOLTAMMETRIC DETERMINATION OF CHROMIUM(VI) IN OVERLYING AND INTERSTITIAL WATERS ISOLATED FROM SEDIMENTS CONTAMINATED BY TANNERY WASTE [J].
Bobrowski, Andrzej ;
Kapturski, Pawel ;
Zarebski, Jerzy ;
Dominik, Janusz ;
Vignati, Davide A. L. .
ANALYTICAL LETTERS, 2012, 45 (5-6) :495-507
[9]   Bismuth-based porous screen-printed carbon electrode with enhanced sensitivity for trace heavy metal detection by stripping voltammetry [J].
Chen, Chen ;
Niu, Xiangheng ;
Chai, Yan ;
Zhao, Hongli ;
Lan, Minbo .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 :339-342
[10]   Determination of trace heavy metals by sequential injection-anodic stripping voltammetry using bismuth film screen-printed carbon electrode [J].
Chuanuwatanakul, Suchada ;
Dungchai, Wijitar ;
Chailapakul, Orawon ;
Motomizu, Shoji .
ANALYTICAL SCIENCES, 2008, 24 (05) :589-594