Diagnostic and Clinical Predictive Value of Optic Nerve Sheath Diameter Measurement in Children with Increased Intracranial Pressure

被引:2
|
作者
Kendir, Ozlem Tolu [1 ,4 ]
Yilmaz, Hayri Levent [1 ]
Balli, Huseyin Tugsan [2 ]
Gokay, Sinem Sari [1 ]
Unal, Ilker [3 ]
Ozkaya, Ahmet Kagan [1 ,5 ]
机构
[1] Cukurova Univ, Dept Pediat, Emergency Care Unit, Balcali Hosp, Adana, Turkey
[2] Cukurova Univ, Balcali Hosp, Dept Radiol, Adana, Turkey
[3] Cukurova Univ, Dept Biostat, Balcali Hosp, Applicat & Res Ctr, Adana, Turkey
[4] Akdeniz Univ, Dept Pediat, Emergency Care Unit, Antalya, Turkey
[5] Karadeniz Tech Univ, Dept Pediat, Emergency Care Unit, Trabzon, Turkey
关键词
Optic nerve sheath measurement; increased intracranial pressure; cerebral edema; CARE OCULAR ULTRASOUND; SONOGRAPHIC MEASUREMENT; IDENTIFICATION; TOMOGRAPHY; WINDOW; EDEMA; ONSD;
D O I
10.14744/etd.2021.43809
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: In this study, we aimed to determine the diagnostic and clinical predictive value of optic nerve sheath diameter (ONSD) measurement in pediatric patients suspected of increased intracranial pressure (IICP) by comparing sonographic ONSD values with radiological parameters and controls. Materials and Methods: In total, 57 pediatric patients with suspected IICP who underwent computed tomography (CT) scans were included in this prospective, observational study; meanwhile, 35 patients were included as controls. Measurements were obtained while the patients were in supine position with their eyes closed, and transbulbar images of both eyes were obtained via a 6-15 MHz linear probe. The CT scans were assessed by a radiologist blinded to sonographic measurements. Glasgow coma scale of patients, service where they were followed, clinical results, CT, and ONSD values were assessed in this study. Results: In the patient group, 26 of the patients were girls (35.4%), and the mean age was 138 +/- 56 months (min-max: 82-194 months). Meanwhile, in the control group, 18 of the patients were girls (40.9%), and mean age was 151 +/- 45 months (min-max: 106-196 months). As per our findings, 31 patients (54.4%) presented with high-energy trauma. Mean ONSD was 0.5 +/- 0.07 cm in the patient group, whereas it was 0.3 +/- 0.02 cm in the control group (p=0.008). It was 0.55 +/- 0.07 cm in patients with cerebral edema (CE) on CT scan (p=0.013). Based on the presence of CE as detected via CT scan, cut-off value for measurement was determined to be 0.49 cm, with 83.33% sensitivity and 68.42% specificity (AUC: 0.784). Conclusion: Optic nerve sheath measurement can be utilized to immediately support diagnosis and predict follow-up in the assessment of pediatric patients with ICP elevation.
引用
收藏
页码:554 / 559
页数:6
相关论文
共 50 条
  • [31] Diagnostic and prognostic value of the optic nerve sheath diameter with respect to the intracranial pressure and neurological outcome of patients following hemicraniectomy
    Gao, Yuzhi
    Li, Qiang
    Wu, Chunshuang
    Liu, Shaoyun
    Zhang, Mao
    BMC NEUROLOGY, 2018, 18
  • [32] Detection of increased intracranial pressure in trans-oral robotic thyroidectomy using optic nerve sheath diameter measurement
    Lim, Hyunyoung
    Kim, Eugene
    Kim, Soo Yeon
    Kim, Ji-Yoon
    Jung, Yundo
    Lee, Tagkeun
    Kim, Nayeon
    Tae, Kyung
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2023, 45 (02): : 329 - 336
  • [33] Noninvasive Transorbital Assessment of the Optic Nerve Sheath in Children: Relationship Between Optic Nerve Sheath Diameter, Deformability Index, and Intracranial Pressure
    Padayachy, Llewellyn
    Brekken, Reidar
    Fieggen, Graham
    Selbekk, Tormod
    OPERATIVE NEUROSURGERY, 2019, 16 (06) : 726 - 733
  • [34] Diagnostic value of the optic nerve sheath diameter in pseudotumor cerebri
    Bekerman, Inessa
    Sigal, Tal
    Kimiagar, Itzhak
    Almer, Zina Evy
    Vaiman, Michael
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 30 : 106 - 109
  • [35] Can optic nerve sheath diameter assess increased intracranial pressure in pneumoperitoneum and trendelenburg position?
    Kamhawy, Ghada A.
    Khamis, Fatma M.
    El-Said, Galal H.
    Hassan, Nada T.
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2019, 35 (01): : 80 - 87
  • [36] The value of optic nerve sheath diameter measurement in assessing intracranial pressure using bedside ultrasound in resource limited setting
    Bizuneh, Y.
    Laeke, T.
    Semework, M.
    Tadele, A.
    Tirsit, A.
    Worku, G.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2021, 26 : 206 - 206
  • [37] The value of optic nerve sheath diameter measurement in assessing intracranial pressure using bedside ultrasound in resource limited setting
    Tirsit, A.
    Supsup, T. Laeke
    Supsup, Y. Bizuneh
    Supsup, A. Tadele
    Supsup, M. Semework
    Worku, G.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2021, 26 : 265 - 266
  • [38] Bedside Optic Nerve Sheath Diameter Assessment in the Identification of Increased Intracranial Pressure in Suspected Idiopathic Intracranial Hypertension
    Irazuzta, Jose E.
    Brown, Martha E.
    Akhtar, Javed
    PEDIATRIC NEUROLOGY, 2016, 54 : 35 - 38
  • [39] Advancements in Ultrasound Techniques for Evaluating Intracranial Pressure Through Optic Nerve Sheath Diameter Measurement
    Fan, Wei-Ze
    Jiang, Jun-Rong
    Zang, Hui-Ling
    Shen, Xiao-Hui
    Cheng, Hui
    Yang, Wen-Juan
    Wang, Hui
    Jing, Li-Xing
    WORLD NEUROSURGERY, 2024, 189 : 285 - 290
  • [40] Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter
    Li-juan Wang
    Yan Yao
    Liang-shu Feng
    Yu-zhi Wang
    Nan-nan Zheng
    Jia-chun Feng
    Ying-qi Xing
    Scientific Reports, 7