A quasiexact reconstruction algorithm for helical CT using a 3-Pi acquisition

被引:53
作者
Bontus, C [1 ]
Köhler, T [1 ]
Proksa, R [1 ]
机构
[1] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
关键词
computer tomography; exact reconstruction; filtered backprojection;
D O I
10.1118/1.1601913
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, an exact reconstruction method for helical CT was published by A. Katsevich. The algorithm is of the filtered backprojection type and is, therefore, computationally efficient. Moreover, during backprojection, only data are used which correspond to an illumination interval of 180 as seen from the object-point. We propose a new reconstruction method, which is applicable to data obtained with a 3-Pi acquisition [IEEE Trans. Med. Imaging 19, 848-863 (2000)]. The method uses the same filter types as the Katsevich algorithm, but the directions and the number of the filter lines are chosen differently. For the derivation of the new algorithm, we analyze the relationship of the Katsevich method and radon inversion. A certain radon plane can intersect with the backprojection interval related to a 3-Pi acquisition either once, three, or five times. In analogy to the definition of quasiexactness introduced by Kudo et al. for a 1-Pi acquisition, we use the term quasiexactness for algorithms on a 3-Pi acquisition, if radon planes with one or three intersections within the backprojection interval are treated correctly. Using the results on the relationship with radon inversion, we can prove that our algorithm is quasiexact in this sense. We use simulation results in order to demonstrate that the algorithm yields excellent image quality. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2493 / 2502
页数:10
相关论文
共 23 条
[1]  
Bontus C., 2001, P 6 INT M FULL 3 DIM, P199
[2]  
DANIELSSON PE, 1997, P 3D 97 C NEM PA
[3]   A solution to the long-object problem in helical cone-beam tomography [J].
Defrise, M ;
Noo, F ;
Kudo, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03) :623-643
[4]  
Gradshteyn I.S., 1994, Tables of Integrals, Series, and Products
[5]  
HEUSCHER D, 1999, P 3D 99 C EGM AAN ZE
[6]   Advanced single-slice rebinning in cone-beam spiral CT [J].
Kachelriess, M ;
Schaller, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (04) :754-772
[7]   Theoretically exact filtered backprojection-type inversion algorithm for spiral CT [J].
Katsevich, A .
SIAM JOURNAL ON APPLIED MATHEMATICS, 2002, 62 (06) :2012-2026
[8]   Analysis of an exact inversion algorithm for spiral cone-beam CT [J].
Katsevich, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15) :2583-2597
[9]  
KATSEVICH A, UNPUB IMPROVED EXACT
[10]  
Katsevich A, 2003, INT J MATH MATH SCI, V2003, DOI DOI 10.1155/S0161171203209315