Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms A Prospective Study in 29 Patients With 34 Aneurysms

被引:254
|
作者
Lubicz, Boris [1 ]
Collignon, Laurent [3 ]
Raphaeli, Gai [1 ]
Pruvo, Jean-Pierre [4 ]
Bruneau, Michael [2 ]
De Witte, Olivier [2 ]
Leclerc, Xavier [4 ]
机构
[1] Erasme Univ Hosp, Dept Neuroradiol, B-1070 Brussels, Belgium
[2] Erasme Univ Hosp, Dept Neurosurg, B-1070 Brussels, Belgium
[3] CHR Citadelle, Dept Radiol, Liege, Belgium
[4] Roger Salengro Univ Hosp, Dept Neuroradiol, Lille, France
关键词
detachable coils; intracranial aneurysms; stents; RECONSTRUCTION;
D O I
10.1161/STROKEAHA.110.589911
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-The purpose of this study is to report our preliminary experience with the flow-diverter Silk stent for the endovascular treatment of intracranial aneurysms. Methods-This prospective study was approved by the authors' ethical committees. Twenty-nine patients with 34 fusiform or wide-necked unruptured aneurysms were included and treated by Silk stent placement alone by 2 physicians in 3 different centers. Technical issues, immediate findings, delayed complications, clinical follow-up, and imaging follow-up at 3 and 6 months were assessed. Results-Endovascular treatment was successfully performed in 26 patients (90%). In 3 patients, the stent could not be delivered. Mortality and morbidity rates were of 4% (1 of 26) and 15% (4 of 26), respectively; 1 patient died from a delayed aneurysm rupture related to stent migration, 3 experienced a thromboembolic event, and 1 patient developed progressive visual disturbances related to an increased mass effect. Clinical outcome in 25 patients was unchanged (n=19), improved (n=2), or worsened (=4). Angiographic follow-up in 24 patients (29 aneurysms) showed 20 complete occlusions (69%), 1 neck remnant (3.5%), and 8 incomplete occlusions (27.5%). Significant parent artery stenosis at 6 months occurred in 8 cases (33%). Conclusions-Despite the potential interest of the Silk flow-diverter stent to treat complex intracranial aneurysms without coils, the delayed complication rate is quite high and leads to use this technique only in selective cases. (Stroke. 2010;41:2247-2253.)
引用
收藏
页码:2247 / 2253
页数:7
相关论文
共 50 条
  • [1] The Silk flow-diverter stent for endovascular treatment of intracranial aneurysms
    Alghamdi, Faisal
    Morais, Ricardo
    Scillia, Pietro
    Lubicz, Boris
    EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (06) : 753 - 762
  • [2] Pipeline Flow-Diverter Stent for Endovascular Treatment of Intracranial Aneurysms: Preliminary Experience in 20 Patients with 27 Aneurysms
    Lubicz, Boris
    Collignon, Laurent
    Raphaeli, Gai
    De Witte, Olivier
    WORLD NEUROSURGERY, 2011, 76 (1-2) : 114 - 119
  • [3] Endovascular Treatment of Wide Necked Ruptured Saccular Aneurysms with Flow-Diverter Stent
    Duman, Enes
    Coven, Ilker
    Yildirim, Erkan
    Yilmaz, Cem
    Pinar, H. Ulas
    TURKISH NEUROSURGERY, 2017, 27 (03) : 362 - 367
  • [4] Endovascular treatment of intracranial aneurysms with flow-diverter stents: preliminary single-centre experience
    Malatesta, Emanuele
    Nuzzi, Nunzio Paolo
    Divenuto, Ignazio
    Fossaceca, Rita
    Lombardi, Mariangela
    Cerini, Paolo
    Guzzardi, Giuseppe
    Stecco, Alessandro
    Andreula, Cosma
    Carriero, Alessandro
    RADIOLOGIA MEDICA, 2013, 118 (06): : 971 - 983
  • [5] Surpass Flow Diverter in the Treatment of Intracranial Aneurysms: A Prospective Multicenter Study
    Wakhloo, A. K.
    Lylyk, P.
    de Vries, J.
    Taschner, C.
    Lundquist, J.
    Biondi, A.
    Hartmann, M.
    Szikora, I.
    Pierot, L.
    Sakai, N.
    Imamura, H.
    Sourour, N.
    Rennie, I.
    Skalej, M.
    Beuing, O.
    Bonafe, A.
    Mery, F.
    Turjman, F.
    Brouwer, P.
    Boccardi, E.
    Valvassori, L.
    Derakhshani, S.
    Litzenberg, M. W.
    Gounis, M. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (01) : 98 - 107
  • [6] The SILK flow diverter in the treatment of intracranial aneurysms
    Murthy, Santosh B.
    Shah, Shreyansh
    Shastri, Aditi
    Rao, Chethan P. Venkatasubba
    Bershad, Eric M.
    Suarez, Jose I.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (02) : 203 - 206
  • [7] Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study
    Berge, J.
    Biondi, A.
    Machi, P.
    Brunel, H.
    Pierot, L.
    Gabrillargues, J.
    Kadziolka, K.
    Barreau, X.
    Dousset, V.
    Bonafe, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1150 - 1155
  • [8] Flow diverter stent for treatment of cerebral aneurysms: A report of 130 patients with 134 aneurysms
    Nguyen Thai Binh
    Vu Dang Luu
    Pham Minh Thong
    Nguyen Ngoc Cuong
    Nguyen Quang Anh
    Tran Anh Tuan
    Le Tuan Linh
    Nguyen Tat Thien
    Uddin, Md Jamal
    Thien Chu Dinh
    Dinh-Toi Chu
    HELIYON, 2020, 6 (02)
  • [9] Cerebral Revascularization for Aneurysms in the Flow-Diverter Era
    Straus, David C.
    da Silva, Harley Brito
    McGrath, Lynn
    Levitt, Michael R.
    Kim, Louis J.
    Ghodke, Basavaraj V.
    Barber, Jason K.
    Sekhar, Laligam N.
    NEUROSURGERY, 2017, 80 (05) : 759 - 767
  • [10] Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis
    Arrese, Ignacio
    Sarabia, Rosario
    Pintado, Rebeca
    Delgado-Rodriguez, Miguel
    NEUROSURGERY, 2013, 73 (02) : 193 - 199