The influences of cooling regimes on fire resistance of ultra-high performance concrete under static-dynamic coupled loads

被引:22
作者
Liu, Kai [1 ]
Wu, Chengqing [3 ]
Li, Xibing [2 ]
Liu, Jian [1 ]
Tao, Ming [2 ]
Fang, Jianguang [3 ]
Xu, Shenchun [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Cent South Univ, Sch Resources & Safety Engn, Changsha 410083, Hunan, Peoples R China
[3] Univ Technol, Sch Civil & Environm Engn, Sydney, NSW 2007, Australia
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Ultra-high performance concrete (UHPC); Cooling regime; Elevated temperature; Static-dynamic loads; HIGH-STRENGTH CONCRETE; HIGH-STRAIN-RATE; HIGH-TEMPERATURE; MECHANICAL-PROPERTIES; ELEVATED-TEMPERATURE; STEEL FIBERS; EXPOSURE; MICROSTRUCTURE; POLYPROPYLENE; BEHAVIOR;
D O I
10.1016/j.jobe.2021.103336
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cooling regimes have a significant effect on the mechanical properties of ultra-high performance concrete (UHPC) after exposure to elevated temperatures. Load-bearing structures are easily subjected to the coupling action of static and dynamic loads in the fire. This study investigated the dynamic behavior and failure characteristics of UHPC after exposure to heating-cooling treatments. The variations in the P-wave velocities, compressive strengths, elastic modulus and dynamic increase factor (DIF) of the specimens in terms of the different cooling regimes (natural cooling, water cooling) were analyzed. The experimental results indicated that as compared to natural cooling, water cooling caused significant losses in the P-wave velocities, quasi-static and dynamic compressive strength, and dynamic elastic modulus due to the thermal shock induced by water cooling. As the target temperature increased from 250 to above 500 degrees C, the difference of mechanical property losses varied from small to large, indicating that the thermal shock induced by water cooling caused insignificant damage to the specimen at 250 degrees C, whereas considerable damage was induced to the specimen above 500 degrees C. Water cooling enhanced the DIF values of the specimens below 500 degrees C, but reduced the DIF values at 750 degrees C. Axial static-pressure loading improved the mechanical properties of the specimen when UHPC was in the elastic phase, which could be attributed to the initial microcracks and pores closed and compacted by the axial static-pressure. However, when the axial static-pressure exceeded the elastic limit of UHPC, microcracks were prone to expansion under impact loads and the mechanical properties of the specimens deteriorated rapidly. Likewise, the failure pattern of the specimen under a given impact load was mainly determined by the heating temperature and cooling regime, whereas the axial static-pressure loading could only affect the fragment size.
引用
收藏
页数:14
相关论文
共 47 条
[1]  
Abramowicz M., 2005, Journal of Civil Engineering and Management, V11, P85, DOI 10.1080/13923730.2005.9636336
[2]   Mechanical properties of steel fiber-reinforced UHPC mixtures exposed to elevated temperature: Effects of exposure duration and fiber content [J].
Ahmad, Shamsad ;
Rasul, Mehboob ;
Adekunle, Saheed Kolawole ;
Al-Dulaijan, Salah U. ;
Maslehuddin, Mohammed ;
Ali, Syed Imran .
COMPOSITES PART B-ENGINEERING, 2019, 168 :291-301
[3]   RETRACTED: Performance evaluation of high-strength concrete reinforced with basalt fibers exposed to elevated temperatures (Retracted article. See vol. 103, 2025) [J].
Alaskar, Abdulaziz ;
Albidah, Abdulrahman ;
Alqarni, Ali Saeed ;
Alyousef, Rayed ;
Mohammadhosseini, Hossein .
JOURNAL OF BUILDING ENGINEERING, 2021, 35
[4]   Water-induced variations in dynamic behavior and failure characteristics of sandstone subjected to simulated geo-stress [J].
Cai, Xin ;
Zhou, Zilong ;
Du, Xueming .
INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2020, 130
[5]   Dynamic compressive properties of reactive powder concrete at high temperature: A review [J].
Cao, Shaojun ;
Hou, Xiaomeng ;
Rong, Qin .
CEMENT & CONCRETE COMPOSITES, 2020, 110
[6]   Comparison between high strength concrete and normal strength concrete subjected to high temperature [J].
Chan, SYN ;
Peng, GF ;
Chan, JKW .
MATERIALS AND STRUCTURES, 1996, 29 (194) :616-619
[7]   Combined effects of high temperature and high strain rate on normal weight concrete [J].
Chen, Li ;
Fang, Qin ;
Jiang, Xiquan ;
Ruan, Zheng ;
Hong, Jian .
INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2015, 86 :40-56
[8]   Test on mechanical behavior of pultruded concrete-filled GFRP tubular short columns after elevated temperatures [J].
Guo, Zhan ;
Xia, Lujing ;
Lin, Quan ;
Chen, Yu .
COMPOSITE STRUCTURES, 2021, 257
[9]   Improvement effect of fiber alignment on resistance to elevated temperature of ultra-high performance concrete [J].
Huang, Huanghuang ;
Wang, Rui ;
Gao, Xiaojian .
COMPOSITES PART B-ENGINEERING, 2019, 177
[10]   Experimental study on dynamic behaviours of concrete after exposure to high temperatures up to 700 A°C [J].
Huo, J. S. ;
He, Y. M. ;
Xiao, L. P. ;
Chen, B. S. .
MATERIALS AND STRUCTURES, 2013, 46 (1-2) :255-265