Clinical and radiologic outcomes following total shoulder arthroplasty using Arthrex Eclipse stemless humeral component with minimum 2 years' follow-up

被引:23
作者
Gallacher, Sian [1 ]
Williams, Huw L. M. [1 ]
King, Andrew [1 ]
Kitson, Jeff [1 ]
Smith, Chris D. [1 ]
Thomas, William J. [1 ]
机构
[1] Royal Devon & Exeter Hosp, Princess Elizabeth Orthopaed Ctr, Barrack Rd, Exeter EX2 5DW, Devon, England
关键词
Shoulder; arthroplasty; stemless prosthesis; shoulder replacement; outcomes; OSS; radiologic; ROM; PROSTHETIC DESIGN; HEAD SIZE; REPLACEMENT;
D O I
10.1016/j.jse.2018.05.039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Stemless humeral components benefit from less morbidity, better reproduction of the humeral anatomy, ease of revision. and fewer stein-related complications. Encouraging results are available up to 9 years after surgery from the designer's series. This is an independent study of 100 consecutive Eclipse stemless prostheses for osteoarthritis with a minimum 2-year follow-up (range, 2-6 years). Methods: We included only total shoulder arthroplasties performed for osteoarthritis. The primary outcome was the Oxford Shoulder Score (OSS) after 2 years. Secondary outcome measures were change in shoulder range of movement and radiographic analysis of prosthesis size and position. Results: The mean OSS at 2 years was 38 of 48. with a mean improvement of +19 points (range, +17 to +22 points; P < .001). There was no significant deterioration in OSS after 3 or 4 years' follow-up. Statistically significant improvement was seen in arm elevation and external rotation (P < .001). There were 5 reoperations-I for impingement of the biceps stump and 4 revisions to reverse arthroplasty for cuff failure. Of the prostheses, 92% were sized within 2 mm of the anatomic head size, and in 76% of prostheses, the center of rotation was within 3 mm of the native anatomy. An incomplete radiolucent line was present in zone B (around the cage screw) in a single patient at 2 years following surgery. There were no cases of loosening or infection. Conclusion: The functional and radiographic outcomes of Eclipse total shoulder replacement are excellent. We were able to accurately reproduce the native anatomy in the majority of cases. with no implant loosening. at 2 to 6 years' follow-up. (C) 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:2191 / 2197
页数:7
相关论文
共 20 条
  • [1] Complications in shoulder arthroplasty: an analysis of 485 cases
    Aldinger, Peter R.
    Raiss, Patric
    Rickert, Markus
    Loew, Markus
    [J]. INTERNATIONAL ORTHOPAEDICS, 2010, 34 (04) : 517 - 524
  • [2] Radiographic assessment of prosthetic humeral head size after anatomic shoulder arthroplasty
    Alolabi, Bashar
    Youderian, Ari R.
    Napolitano, Larry
    Szerlip, Benjamin W.
    Evans, Peter J.
    Nowinski, Robert J.
    Ricchetti, Eric T.
    Iannotti, Joseph P.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (11) : 1740 - 1746
  • [3] Periprosthetic Humeral Fractures During Shoulder Arthroplasty
    Athwal, George S.
    Sperling, John W.
    Rispoli, Damian M.
    Cofield, Robert H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03) : 594 - 603
  • [4] The three-dimensional geometry of the proximal humerus - Implications for surgical technique and prosthetic design
    Boileau, P
    Walch, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05): : 857 - 865
  • [5] Brolin TJ, 2017, JBJS REV, V5, DOI 10.2106/JBJS.RVW.16.00096
  • [6] Stemless shoulder arthroplasty: current status
    Churchill, R. Sean
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (09) : 1409 - 1414
  • [7] Is the humeral stem useful in anatomic total shoulder arthroplasty?
    Collin, Philippe
    Matsukawa, Tetsu
    Boileau, Pascal
    Brunner, Ulrich
    Walch, Gilles
    [J]. INTERNATIONAL ORTHOPAEDICS, 2017, 41 (05) : 1035 - 1039
  • [8] Questionnaire on the perceptions of patients about shoulder surgery
    Dawson, J
    Fitzpatrick, R
    Carr, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04): : 593 - 600
  • [9] Friedman R J, 1997, Am J Orthop (Belle Mead NJ), V26, P265
  • [10] Complications of unconstrained shoulder prostheses
    Gonzalez, Jean-Francois
    Alami, Ghassan B.
    Baque, Francois
    Walch, Gilles
    Boileau, Pascal
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (04) : 666 - 682