Chemometric classification of gunshot residues based on energy dispersive X-ray microanalysis and inductively coupled plasma analysis with mass-spectrometric detection

被引:48
作者
Steffen, S.
Otto, M.
Niewoehner, L.
Barth, M.
Brozek-Mucha, Z.
Blegstraaten, J.
Horvath, R.
机构
[1] Inst Analyt Chem, TU Bergakademie Freiberg, D-09599 Freiberg, Germany
[2] Forens Sci Inst, Bundeskriminalamt, D-65193 Wiesbaden, Germany
[3] Inst Ekspertys Sadowych, PL-31033 Krakow, Poland
[4] Nederlands Forens Inst, Fys Technol, NL-2497 GB The Hague, Netherlands
[5] Inst Forens Sci, Kriminalisticky Expertizny Ustav, SK-81272 Bratislava, Slovakia
关键词
SEM/EDX; ICP-MS; regularized discriminant analysis; fast Fourier transformation; GSR;
D O I
10.1016/j.sab.2007.04.005
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A gunshot residue sample that was collected from an object or a suspected person is automatically searched for gunshot residue relevant particles. Particle data (such as size, morphology, position on the sample for manual relocation, etc.) as well as the corresponding X-ray spectra and images are stored. According to these data, particles are classified by the analysis-software into different groups: 'gunshot residue characteristic'. 'consistent with gunshot residue' and environmental particles, respectively. Potential gunshot residue particles are manually checked and - if necessary - confirmed by the operating forensic scientist. As there are continuing developments on the ammunition market worldwide, it becomes more and more difficult to assign a detected particle to a particular ammunition brand. As well, the differentiation towards environmental particles similar to gunshot residue is getting more complex. To keep external conditions unchanged, gunshot residue particles were collected using a specially designed shooting device for the test shots revealing defined shooting distances between the weapon's muzzle and the target. The data obtained as X-ray spectra of a number of particles (3000 per ammunition brand) were reduced by Fast Fourier Transformation and subjected to a chemometric evaluation by means of regularized discriminant analvsis. In addition to the scanning electron microscopy in combination with energy dispersive X-ray microanalysis results, isotope ratio measurements based on inductively coupled plasma analysis with mass-spectrometric detection were carried out to provide a supplementary feature for an even lower risk of misclassification. (C) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:1028 / 1036
页数:9
相关论文
共 10 条
[1]   A comparative study of gunshot residue originating from 9 mm Luger ammunition from various producers [J].
Brozek-Mucha, Z ;
Zadora, G ;
Dane, F .
SCIENCE & JUSTICE, 2003, 43 (04) :229-235
[2]   Grouping of ammunition types by means of frequencies of occurrence of GSR [J].
Brozek-Mucha, Z ;
Zadora, G .
FORENSIC SCIENCE INTERNATIONAL, 2003, 135 (02) :97-104
[3]   Evaluation of the possibility of differentiation between various types of ammunition by means of GSR examination with SEM-EDX method [J].
Brozek-Mucha, Z ;
Jankowicz, A .
FORENSIC SCIENCE INTERNATIONAL, 2001, 123 (01) :39-47
[4]  
CASTELL S, 1997, THESIS EUROPA FACHHO
[5]  
CHEYLAN P, 2003, IAFS M MONTP
[6]   REGULARIZED DISCRIMINANT-ANALYSIS [J].
FRIEDMAN, JH .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1989, 84 (405) :165-175
[7]  
Lichtenberg W, 1990, Forensic Sci Rev, V2, P37
[8]  
STEFFEN S, 2006, THESIS TU BERGAKADEM
[9]   SURFACE-ANALYSIS AND SURFACE MEASURING TECHNIQUES IN FIREARM OFFENSES [J].
WENZ, HW ;
LICHTENBERG, WJ ;
KATTERWE, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 341 (3-4) :155-165
[10]  
Zupan J, 1989, ALGORITHMS CHEM