Open reduction and compression with double Kirschner wires for the treatment of old bony mallet finger

被引:12
作者
Tang, Junjun [1 ]
Wu, Kejian [1 ]
Wang, Jinchang [1 ]
Zhand, Jian [1 ]
机构
[1] Gen Hosp Peoples Liberat Army China, Forth Med Ctr, Dept Orthoped, Beijing, Peoples R China
关键词
Mallet finger; Fracture fixation; Avulsion fracture; Flexion angle; Kirschner wires; SUTURE TECHNIQUE; FRACTURES; COMPLICATIONS; MANAGEMENT;
D O I
10.1186/s13018-019-1513-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The management of old bony mallet fingers is complicated. The aim of the study is to present a new method of open reduction and compression with double Kirschner wires (K-wires) in treating old bony mallet fingers. Methods This was a retrospective analysis of patients with old closed bony mallet fingers treated between June 2013 and December 2016. Complications were observed. The range of motion (ROM) of the DIP joints was measured using a protractor. At the last follow-up, anteroposterior and lateral X-ray of the affected finger was performed, the flatness of the articular surface was scored, and the results were graded using Crawford's criteria. Results Seventeen patients were followed up for 8 (6-19) months. The width of the avulsion fracture block accounted for 25-62% of the articular surface of the distal phalanx. Twelve (70.6%) patients had anterior dislocation of the interphalangeal joint. All patients reported healing at the fracture sites. Healing time was 7.6 +/- 2.1(5-13) weeks. All patients had incision healing of I/Class A. Lateral X-ray showed 13 and four patients had excellent and good articular surface flatness, respectively. At the last follow-up, no traumatic arthritis was present. Only one patient developed mild pain after surgery (VAS score of 3). Postoperative ROM was 76.5 +/- 10.6 degrees (P = 0.0625 vs. healthy side). At the last follow-up, the angle of loss of dorsiflexion was 0-10 degrees (P < 0.0001 vs. baseline). The flexion angle was 50-90 degrees (P = 0.0625 vs. healthy side). Conclusions Open reduction and compression with double K-wires is feasible in treating old bony mallet finger.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Alla Sreenivasa R, 2014, Hand (N Y), V9, P138, DOI 10.1007/s11552-014-9609-y
  • [2] TREATMENT OF CHRONIC MALLET FRACTURES USING EXTENSION-BLOCK KIRSCHNER WIRE
    Asano, Kenichi
    Inoue, Goro
    Shin, Masaki
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2014, 19 (03) : 399 - 403
  • [3] Mallet finger
    Bendre, AA
    Hartigan, BJ
    Kalainov, DM
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2005, 13 (05) : 336 - 344
  • [4] BRZEZIENSKI MA, 1995, HAND CLIN, V11, P373
  • [5] THE MOLDED POLYTHENE SPLINT FOR MALLET FINGER DEFORMITIES
    CRAWFORD, GP
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1984, 9A (02): : 231 - 237
  • [6] A biomechanical study of distal interphalangeal joint subluxation after mallet fracture injury
    Husain, Sohail N.
    Dietz, Jeffrey F.
    Kalainov, David M.
    Lautenschlager, Eugene P.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (01): : 26 - 30
  • [7] Ishiguro T, 1997, Tech Hand Up Extrem Surg, V1, P95, DOI 10.1097/00130911-199706000-00005
  • [8] Ishiguro T, 1986, Nihon Seikeigeka Gakkai Zasshi, V60, P227
  • [9] Ishiguro T., 1988, J JPN SOC SURG HAND, V5, P444
  • [10] The Thompson Procedure for Chronic Mallet Finger Deformity
    Kanaya, Kohei
    Wada, Takuro
    Yamashita, Toshihiko
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (07): : 1295 - 1300