4D XCAT phantom for multimodality imaging research

被引:967
|
作者
Segars, W. P. [1 ]
Sturgeon, G. [1 ,2 ]
Mendonca, S. [1 ]
Grimes, Jason [1 ]
Tsui, B. M. W. [3 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[3] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
基金
美国国家卫生研究院;
关键词
medical imaging simulation; computer phantom; SPECT; PET; CT; NCAT PHANTOM; SIMULATION; SPECT; MODELS; ATTENUATION; PERFORMANCE; CT;
D O I
10.1118/1.3480985
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, "Basic anatomical and physiological data for use in radiological protection: reference values," ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac-and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce realistic, predictive 3D and 4D imaging data from populations of normal and abnormal patients under various imaging parameters, the authors conclude that the XCAT provides an important tool in imaging research to evaluate and improve imaging devices and techniques. In the field of x-ray CT, the phantom may also provide the necessary foundation with which to optimize clinical CT applications in terms of image quality versus radiation dose, an area of research that is becoming more significant with the growing use of CT. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3480985]
引用
收藏
页码:4902 / 4915
页数:14
相关论文
共 50 条
  • [21] Evaluation of amplitude-based sorting algorithm to reduce lung tumor blurring in PET images using 4D NCAT phantom
    Wang, Jiali
    Byrne, James
    Franquiz, Juan
    McGoron, Anthony
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2007, 87 (02) : 112 - 122
  • [22] CT-PET image fusion using the 4D NCAT phantom with the purpose of attenuation correction
    Segars, WP
    Tsui, BMW
    Da Silva, AJ
    Shao, L
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1775 - 1779
  • [23] Intracranial Aneurysm Phantom Segmentation Using a 4D Lattice Boltzmann Method
    Wang, Yan
    Navarro, Laurent
    Zhang, Yue
    Kao, Evan
    Zhu, Yuemin
    Courbebaisse, Guy
    COMPUTING IN SCIENCE & ENGINEERING, 2017, 19 (04) : 56 - 67
  • [24] Evaluation of the Elekta Symmetry™ 4D IGRT System by Using a Moving Lung Phantom
    Shin, Hun-Joo
    Kim, Shin-Wook
    Kay, Chul Seung
    Seo, Jae-Hyuk
    Lee, Gi-Woong
    Kang, Ki-Mun
    Jang, Hong Seok
    Kang, Young-nam
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 260 - 263
  • [25] A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus
    Allard, Louise
    Soulez, Gilles
    Chayer, Boris
    Qin, Zhao
    Roy, David
    Cloutier, Guy
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] Dynamic Hepatocellular Carcinoma Model Within a Liver Phantom for Multimodality Imaging
    Ahmad, Muntaser S.
    Suardi, Nursakinah
    Shukri, Ahmad
    Ab Razak, Nik Noor Ashikin Nik
    Oglat, Ammar A.
    Makhamrah, Osama
    Mohammad, Hjouj
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2020, 7
  • [27] 4D PET: Beyond Conventional Dynamic PET Imaging
    Rahmim, Arman
    Tang, Jing
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2008, 16 (01): : 1 - 13
  • [28] The impact of audio-visual biofeedback on 4D PET images: Results of a phantom study
    Yang, Jaewon
    Yamamoto, Tokihiro
    Cho, Byungchul
    Seo, Youngho
    Keall, Paul J.
    MEDICAL PHYSICS, 2012, 39 (02) : 1046 - 1057
  • [29] An Approach to Convert 4D Geometry into a 4D CT Scan
    Villard, P. F.
    Beuve, M.
    Shariat, B.
    WSCG 2006: SHORT PAPERS PROCEEDINGS: 14TH INTERNATIONAL CONFERENCE IN CENTRAL EUROPE ON COMPUTER GRAPHICS, VISUALIZATION AND COMPUTER VISION 2006, 2006, : 163 - 169
  • [30] A 4D Imaging Tool for Lagrangian Particle Tracking in Stirred Tanks
    Cheng, Y.
    Diez, F. J.
    AICHE JOURNAL, 2011, 57 (08) : 1983 - 1996