A novel technique to assess the quality of ventilation during pre-hospital cardiopulmonary resuscitation

被引:22
作者
Aramendi, Elisabete [1 ,2 ]
Lu, Yuanzheng [2 ,3 ]
Chang, Mary P. [2 ]
Elola, Andoni [1 ]
Irusta, Unai [1 ]
Owens, Pamela [2 ]
Idris, Ahamed H. [2 ]
机构
[1] Univ Basque Country, Commun Engn Dept, UPV EHU, Alameda Urquijo S-N, Bilbao 48013, Spain
[2] Univ Texas Southwestern Med Ctr UTSW, Dallas Ft Worth Ctr Resuscitat Res, Dallas, TX 75390 USA
[3] Sun Yat Sen Univ, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
关键词
Ventilation detection; Heart arrest; Bioimpedance; 30:2 CPR; Automatic software; IMPEDANCE CHANGES; MONITOR VENTILATION; PNEUMOGRAPHY; CAPNOGRAM; VOLUMES; PADS;
D O I
10.1016/j.resuscitation.2018.08.016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Devices that measure ventilation in the pre-hospital setting are deficient especially during early cardiopulmonary resuscitation (CPR) before placement of an advanced airway. Consequently, evidence is limited regarding the role of ventilation during early CPR and its effect on outcomes. Objective: To develop software that automatically identifies ventilation waveforms recorded by defibrillators based on changes in transthoracic impedance during standard CPR. Methods: This was an observational, retrospective analysis of non-traumatic pre-hospital cardiac arrest patients who received 30:2 CPR by emergency medical service rescuers. Data was collected from 550 cases recorded by the bioimpedance channel of defibrillators. Two expert clinicians independently assessed all episodes from the time of initial CPR until placement of an advanced airway, defined acceptable ventilation waveforms, and annotated the pauses between compressions with ventilation waveforms. We then developed software that incorporated the expert criteria and automatically annotated pauses with acceptable ventilations. Results: A total of 7396 pauses were analyzed, mean(SD) duration of 30:2 CPR was 13 (8) min, with 13 (10) pauses/patient, and mean pause duration of 6 (3) s. Reviewer 1 and reviewer 2 identified 2375 and 2249 pauses with any acceptable ventilation, respectively, with an inter-rater reliability of 0.94. The novel software program reproduced expert annotation with excellent agreement ( > 0.8) and high accuracy, both sensitivity and specificity above 90%, compared to two reviewers. The software presented a substantial agreement with the reviewers (kappa > 0.73) for ventilation counts in the pauses. Conclusion: We developed a novel and reliable strategy that enables investigation of ventilation quality during standard CPR using thoracic bioimpedance. This strategy would allow a timely and reliable automatic annotation of large scale resuscitation datasets.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 33 条
[1]   Approximate is better than "exact" for interval estimation of binomial proportions [J].
Agresti, A ;
Coull, BA .
AMERICAN STATISTICIAN, 1998, 52 (02) :119-126
[2]   VOLUMETRIC DYNAMICS OF RESPIRATION AS MEASURED BY ELECTRICAL IMPEDANCE PLETHYSMOGRAPHY [J].
ALLISON, RD ;
HOLMES, EL ;
NYBOER, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (01) :166-&
[3]   Reliability and accuracy of the thoracic impedance signal for measuring cardiopulmonary resuscitation quality metrics [J].
Alonso, Erik ;
Ruiz, Jesus ;
Aramendi, Elisabete ;
Gonzalez-Otero, Digna ;
Ruiz de Gauna, Sofia ;
Ayala, Unai ;
Russell, James K. ;
Daya, Mohamud .
RESUSCITATION, 2015, 88 :28-34
[4]   Feasibility of the capnogram to monitor ventilation rate during cardiopulmonary resuscitation [J].
Aramendi, Elisabete ;
Elola, Andoni ;
Alonso, Erik ;
Irusta, Unai ;
Daya, Mohamud ;
Russell, James K. ;
Hubner, Pia ;
Sterz, Fritz .
RESUSCITATION, 2017, 110 :162-168
[5]   Hyperventilation-induced hypotension during cardiopulmonary resuscitation [J].
Aufderheide, TP ;
Sigurdsson, G ;
Pirrallo, RG ;
Yannopoulos, D ;
McKnite, S ;
von Briesen, C ;
Sparks, CW ;
Conrad, CJ ;
Provo, TA ;
Lurie, KG .
CIRCULATION, 2004, 109 (16) :1960-1965
[6]   Minimally interrupted cardiac resuscitation by emergency medical services for out-of-hospital cardiac arrest [J].
Bobrow, Bentley J. ;
Clark, Lani L. ;
Ewy, Gordon A. ;
Chikani, Vatsal ;
Sanders, Arthur B. ;
Berg, Robert A. ;
Richman, Peter B. ;
Kern, Karl B. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (10) :1158-1165
[7]   Chest Compression Fraction Determines Survival in Patients With Out-of-Hospital Ventricular Fibrillation [J].
Christenson, Jim ;
Andrusiek, Douglas ;
Everson-Stewart, Siobhan ;
Kudenchuk, Peter ;
Hostler, David ;
Powell, Judy ;
Callaway, Clifton W. ;
Bishop, Dan ;
Vaillancourt, Christian ;
Davis, Dan ;
Aufderheide, Tom P. ;
Idris, Ahamed ;
Stouffer, John A. ;
Stiell, Ian ;
Berg, Robert .
CIRCULATION, 2009, 120 (13) :1241-1247
[8]   Capnography and chest-wall impedance algorithms for ventilation detection during cardiopulmonary resuscitation [J].
Edelson, Dana P. ;
Eilevstjonn, Joar ;
Weidman, Elizabeth K. ;
Retzer, Elizabeth ;
Vanden Hoek, Terry L. ;
Abella, Benjamin S. .
RESUSCITATION, 2010, 81 (03) :317-322
[9]   ELECTRICAL IMPEDANCE PNEUMOGRAPHY FOR SIMPLE NONRESTRICTIVE CONTINUOUS MONITORING OF RESPIRATORY RATE, RHYTHM AND TIDAL VOLUME FOR SURGICAL PATIENTS [J].
FREUNDLICH, JJ ;
ERICKSON, JC .
CHEST, 1974, 65 (02) :181-184
[10]   IMPEDANCE PNEUMOGRAPHY - COMPARISON BETWEEN CHEST IMPEDANCE CHANGES AND RESPIRATORY VOLUMES IN 11 HEALTHY VOLUNTEERS [J].
GRENVIK, A ;
BALLOU, S ;
SAFAR, P ;
MILLEN, JE ;
MCGINLEY, E ;
COOLEY, WL .
CHEST, 1972, 62 (04) :439-&