ENHANCING THERMAL COMFORT OF RESIDENTIAL BUILDINGS THROUGH A DUAL FUNCTIONAL PASSIVE SYSTEM (SOLAR-WALL)

被引:0
作者
Mabdeh, Shouib [1 ]
Al Radaideh, Tamer [1 ]
Hiyari, Montaser [2 ]
机构
[1] Jordan Univ Sci & Technol, Dept Architecture, Irbid 22110, Jordan
[2] Appl Sci Private Univ, Amman 11931, Jordan
来源
JOURNAL OF GREEN BUILDING | 2021年 / 16卷 / 03期
关键词
indoor environmental quality; thermal comfort; indoor operative temperature; passive systems; passive design; INDOOR ENVIRONMENTAL-QUALITY; NATURAL VENTILATION; TROMBE WALLS; PERFORMANCE; CHIMNEY; ENERGY; MODEL; OPTIMIZATION; BEHAVIOR; IEQ;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal comfort has a great impact on occupants' productivity and general wellbeing. Since people spend 80-90% of their time indoors, developing the tools and methods that enhance the thermal comfort for building are worth investigating. Previous studies have proved that using passive systems like Trombe walls and solar chimneys significantly enhanced thermal comfort in inside spaces despite that each system has a specific purpose within a specific climate condition. Hence, the main purpose of this study is to design and configure a new, dual functional passive system, called a solar wall. The new system combines the Trombe wall and solar chimney, and it can cool or heat based on building needs. Simulation software, DesignBuilder, has been used to configure the Solar Wall, and study its impact on indoor operative temperature for the base case. Using the new system, the simulation results were compared with those obtained in the base case and analyzed to determine the most efficient system design parameters and implementation method. The case that gave the best results for solar wall configuration was triple glazed glass and 0.1 cm copper as an absorber (case 11). The results show that using four units (case D) achieves longer thermal comfort levels: 15 to 24 thermal hours during winter (compared to five hours maximum) and 10 to 19 comfort hours in summer (compared to zero).
引用
收藏
页码:155 / 177
页数:23
相关论文
共 46 条
  • [1] Energetic study of a Trombe wall system under different Tunisian building configurations
    Abbassi, Fakhreddine
    Dimassi, Narjes
    Dehmani, Leila
    [J]. ENERGY AND BUILDINGS, 2014, 80 : 302 - 308
  • [2] Energy security in Israel and Jordan: The role of renewable energy sources
    Abu Hamed, Tareq
    Bressler, Lindsey
    [J]. RENEWABLE ENERGY, 2019, 135 : 378 - 389
  • [3] Al horr Yousef, 2016, International Journal of Sustainable Built Environment, V5, P1, DOI 10.1016/j.ijsbe.2016.03.006
  • [4] Simulation of courtyard spaces in a desert climate
    Al-Hafith, Omar
    Satish, B. K.
    Bradbury, Simon
    de Wilde, Pieter
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1997 - 2002
  • [5] Andersen KT., 1995, THEORETICAL CONSIDER
  • [6] [Anonymous], 2012, INT J VENT, DOI DOI 10.1080/14733315.2012.11683965
  • [7] Baharvand M., 2013, J BASIC APPL SCI RES, V3, P8
  • [8] A simple model to study ventilated facades energy performance
    Balocco, C
    [J]. ENERGY AND BUILDINGS, 2002, 34 (05) : 469 - 475
  • [9] Computational techniques and a numerical study of a buoyancy-driven ventilation system
    Bangalee, M. Z. I.
    Miau, J. J.
    Lin, S. Y.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 65 : 572 - 583
  • [10] BOUCHAIR A, 1994, SOLAR CHIMNEY PROMOT