Characterization of the deterioration of externally bonded CFRP-concrete composites using quantitative infrared thermography

被引:34
作者
Lai, W. L. [1 ]
Kou, S. C. [1 ]
Poon, C. S. [1 ]
Tsang, W. F. [2 ]
Lai, C. C. [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Hong Kong, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg & Real Estate, Hong Kong, Hong Kong, Peoples R China
关键词
Interfacial flaws; Interfacial delamination; CFRP-concrete composite; Quantitative infrared thermography; Deterioration;
D O I
10.1016/j.cemconcomp.2010.03.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Defects embedded in externally-bonded CFRP-concrete composite structures reduce the interfacial bond strength and durability. This paper classifies these defects into two types: flaws and delaminations. Flaws are formed during the first application of the CFRP strips onto the concrete surface due to poor workmanship. Delaminations are formed due to stress concentrations related to chemical/physical degradation of the binding layer. In this study, an aggressive environment was simulated by placing the specimens in water baths with elevated temperatures (40 C and 60 degrees C). The sizes of the CFRP-flaws and delaminations were determined by (i) quantitative infrared thermography (QIRT) and (ii) processing of visual images after opening-up the CFRP by direct shear. Experimental results show that apparent flaw sizes determined by QIRT were in good agreement (88% accuracy) with actual flaw sizes determined by the image processing method. The results also show that flaws exhibited little change but the bonding layer showed significant deterioration after exposure to high water temperatures. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:740 / 746
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 2006, Testing of concrete in structures
[2]  
ASTM (American Society for Testing and Materials), 1995, D3039D3039M ASTM
[3]   ACCELERATED TEST METHODS TO DETERMINE THE LONG-TERM BEHAVIOR OF FRP COMPOSITE STRUCTURES - ENVIRONMENTAL-EFFECTS [J].
BANK, LC ;
GENTRY, TR ;
BARKATT, A .
JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 1995, 14 (06) :559-587
[4]   Non-destructive defect characterization of concrete structures reinforced by means of FRP [J].
Galletti, U. ;
Luprano, V. ;
Nenna, S. ;
Spagnolo, L. ;
Tundo, A. .
INFRARED PHYSICS & TECHNOLOGY, 2007, 49 (03) :218-223
[5]   Comparison between pulsed and modulated thermography in glass-epoxy laminates [J].
Giorleo, G ;
Meola, C .
NDT & E INTERNATIONAL, 2002, 35 (05) :287-292
[6]  
Gonzalez R.C., 1987, DIGITAL IMAGE PROCES, VSecond
[7]  
HAYES MD, 1998, FIBER COMPOSITES INF, V98, P1
[8]  
JAMES PH, 1989, REV PROG Q, V8, P801
[9]  
Krapez J.-C., 1991, Research in Nondestructive Evaluation, V3, P81, DOI 10.1080/09349849108968042
[10]   Effects of elevated water temperatures on interfacial delaminations, failure modes and shear strength in externally-bonded CFRP-concrete beams using infrared thermography, gray-scale images and direct shear test [J].
Lai, W. L. ;
Kou, S. C. ;
Poon, C. S. ;
Tsang, W. F. ;
Lai, C. C. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (10) :3152-3160