Exergy analysis of vapour compression-absorption two-stage refrigeration cycle

被引:2
作者
Ozturk, Ilhan Tekin [1 ]
Cimsit, Canan [2 ]
机构
[1] Kocaeli Univ, Engn Fac, Dept Mech Engn, Kocaeli, Turkey
[2] Kocaeli Univ, Golcuk Vocat Sch, Kocaeli, Turkey
关键词
refrigeration; absorption; two-stage refrigeration; energy; exergy; PERFORMANCE; SYSTEM; DESIGN;
D O I
10.1504/IJEX.2021.115648
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, the exergy analysis of vapour compression-absorption two-stage refrigeration cycle has been performed. While NH3-H2O has been used as fluid pair in the absorption section, NH3 has been used in the vapour compression section. To improve the performance of the cycle, it is possible to reduce the total damage by focusing on the parts that cause high exergy damage. Therefore, the detailed exergy analysis has been made for different operating conditions (generator temperature, condenser temperature and intermediate pressure) of the cycle. The exergy destruction rates of each component were calculated and compared. As the generator temperature increases, the highest exergy destruction rates are seen in the generator. The generator exergy destruction rates increase with increasing condenser temperature. Also, the performance coefficient (COPcyclegen) and the exergy efficiency (epsilon) of the novel cycle have been investigated for different the intermediate pressures. The performance coefficient (COPcyclegen) increases as the intermediate pressure increases. Maximum value of the exergy efficiency is obtained at the intermediate pressure of 516.015 kPa. With this cycle, it is possible to refrigerate down by using alternative energy sources. Also, the refrigeration system is environmentally friendly because environmentally safe fluids are used in this cycle.
引用
收藏
页码:210 / 221
页数:12
相关论文
共 18 条
  • [1] Bejan A., 1995, Thermal Design and Optimization
  • [2] An absorption-compression refrigeration system driven by a mid-temperature heat source for low-temperature applications
    Chen, Yi
    Han, Wei
    Jin, Hongguang
    [J]. ENERGY, 2015, 91 : 215 - 225
  • [3] Cimsit C, 2014, ISI BILIM TEK DERG, V34, P19
  • [4] Performance comparison between a conventional vapor compression and compression-absorption single-stage and double-stage systems used for refrigeration
    Colorado, D.
    Rivera, W.
    [J]. APPLIED THERMAL ENGINEERING, 2015, 87 : 273 - 285
  • [5] Dincer I., 2010, REFRIGERATION SYSTEM
  • [6] Exergoeconomic comparison of double effect and combined ejector-double effect absorption refrigeration systems
    Farshi, L. Garousi
    Mahmoudi, S. M. S.
    Rosen, M. A.
    [J]. APPLIED ENERGY, 2013, 103 : 700 - 711
  • [7] Second law comparison of single effect and double effect vapour absorption refrigeration systems
    Gomri, Rabah
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) : 1279 - 1287
  • [8] Comparative performance study and advanced exergy analysis of novel vapor compression-absorption integrated refrigeration system
    Jain, Vaibhav
    Sachdeva, Gulshan
    Kachhwaha, S. S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 172 : 81 - 97
  • [9] Thermodynamic performance analysis of a vapor compression-absorption cascaded refrigeration system
    Jain, Vaibhav
    Kachhwaha, S. S.
    Sachdeva, Gulshan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 685 - 700
  • [10] The role of optimum intermediate pressure in the design of two-stage vapor compression systems: A further investigation
    Jiang, Shuang
    Wang, Shugang
    Jin, Xu
    Yu, Yao
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 70 : 57 - 70