Efficacy and safety of ultrasound-guided high intensity focused ultrasound ablation of symptomatic uterine fibroids in Black women: a preliminary study

被引:21
|
作者
Zhang, C. [1 ,2 ]
Jacobson, H. [3 ]
Ngobese, Z. E. [4 ]
Setzen, R. [3 ]
机构
[1] Chongqing Med Univ, State Key Lab Ultrasound Engn Med, Chongqing, Peoples R China
[2] Suining Cent Hosp, Dept Obstet & Gynecol, Suining, Sichuan, Peoples R China
[3] Chris Hani Baragwanath Acad Hosp, Dept Obstet & Gynaecol, Johannesburg, South Africa
[4] Christ Hani Baragwanath Acad Hosp, Dept Diagnost Imaging & Radiol, Johannesburg, South Africa
基金
对外科技合作项目(国际科技项目);
关键词
Black women; high-intensity focused ultrasound; uterine fibroid; LAPAROSCOPIC MYOMECTOMY; RECURRENCE RATE; MANAGEMENT;
D O I
10.1111/1471-0528.14738
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective To evaluate the therapeutic effect and safety of ultrasound-guided high-intensity focused ultrasound (USgHIFU) treatment on symptomatic uterine fibroids in Black women. Design A feasibility study. Setting Gynaecological department in a teaching hospital in South Africa. Population Premenopausal women with uterus fibroids. Methods Twenty-six patients with 53 fibroids who underwent USgHIFU treatment were enrolled. The USgHIFU treatment information was recorded, including treatment time, sonication time and total energy. Adverse events were also observed and recorded during and after treatment. Main outcome measures Safety and efficacy of USgHIFU for the treatment of uterine fibroids in Black women. Results The median volume of fibroids was 52.7 (interquartile range, 18.6-177.4) cm(3). According to USgHIFU treatment plan, total energy of 298.6 +/- 169.3 kJ (range, 76.0-889.2) within treatment time of 90.3 +/- 43.3 minutes (range, 14.0-208.0), in which sonication time of 774.0 +/- 432.9 seconds (range, 190.0-2224.0) was used to ablate fibroids. The average ablation rate was 80.6 +/- 9.7% (range, 46.5-94.5%). During the procedure, 69.2% of the patients reported lower abdominal pain, 57.7% sciatic/buttock pain, 38.5% burning skin, and 34.6% transient leg pain. No severe complications were observed. Conclusions USgHIFU is feasible and safe to use to treat symptomatic uterine fibroids in Black women.
引用
收藏
页码:12 / 17
页数:6
相关论文
共 50 条
  • [1] Efficacy and Safety of Ultrasound-Guided High-Intensity Focused Ultrasound Ablation in Women With Multiple Uterine Fibroids: An Exploratory Study
    Shi, Liye
    Zhang, Rongsen
    Tao, Siqi
    Yuan, Xiaorui
    Zhang, Jun
    Wang, Beibei
    Xiang, Mengting
    Ren, Zhen
    Cai, Haiyi
    Fu, Chun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (11): : 2378 - 2387
  • [2] Efficacy and safety of ultrasound-guided high-intensity focused ultrasound for uterine fibroids: a preliminary experience
    Cheung, Vincent Y. T.
    Lam, Tina P. W.
    Jenkins, Caroline R.
    Lam, S. W.
    Cheung, Grace K., I
    Chan, Selina S. Y.
    Choi, W. K.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2019, 39 (06) : 833 - 839
  • [3] Preliminary study on ultrasound-guided high-intensity focused ultrasound ablation for treatment of broad ligament uterine fibroids
    Wang, Yiran
    Xu, Yonghua
    Wong, Felix
    Wang, Yi
    Cheng, Yu
    Yang, Lixia
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (02) : 18 - 23
  • [4] SAFETY AND EFFICACY OF ULTRASOUND-GUIDED HIGH-INTENSITY FOCUSED ULTRASOUND TREATMENT FOR UTERINE FIBROIDS AND ADENOMYOSIS
    Lee, Jae-Seong
    Hong, Gi-Youn
    Lee, Kye-Hwa
    Song, Jung-Hwa
    Kim, Tae-Eung
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (12): : 3214 - 3221
  • [5] Safety and Efficacy of Sonographically Guided High-Intensity Focused Ultrasound for Symptomatic Uterine Fibroids Preliminary Study of a Modified Protocol
    Leung, Joyce H. Y.
    Yu, Simon C. H.
    Cheung, Eva C. W.
    Wong, Alyssa S. W.
    Tong, Mabel M. B.
    Ho, Stella S. Y.
    Leung, Vivian Y. F.
    Ahuja, Anil T.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (10) : 1811 - 1818
  • [6] Efficacy, Efficiency, and Safety of Magnetic Resonance-Guided High-Intensity Focused Ultrasound for Ablation of Uterine Fibroids: Comparison with Ultrasound-Guided Method
    Wang, Yi
    Wang, Zhi-Biao
    Xu, Yong-Hua
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (04) : 724 - 732
  • [7] Ultrasound-guided high-intensity focused ultrasound in the treatment of uterine fibroids
    Fan, Hong-Jie
    Zhang, Chao
    Lei, Hong-Tao
    Cun, Jiang-Ping
    Zhao, Wei
    Huang, Jian-Qiang
    Zhai, Yue
    MEDICINE, 2019, 98 (10)
  • [8] A Prediction of NPVR ≥ 80% of Ultrasound-Guided High-Intensity Focused Ultrasound Ablation for Uterine Fibroids
    Yang, Mei-Jie
    Yu, Ren-Qiang
    Chen, Wen-Zhi
    Chen, Jin-Yun
    Wang, Zhi-Biao
    FRONTIERS IN SURGERY, 2021, 8
  • [9] Outcome of unintended pregnancy after ultrasound-guided high-intensity focused ultrasound ablation of uterine fibroids
    Qin, Juan
    Chen, Jin-Yun
    Zhao, Wen-Peng
    Hu, Liang
    Chen, Wen-Zhi
    Wang, Zhi-Biao
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2012, 117 (03) : 273 - 277
  • [10] Alterations in vaginal microbiota in uterine fibroids patients with ultrasound-guided high-intensity focused ultrasound ablation
    Zhang, Ping-Ping
    He, Xue-Ping
    Tang, Wen
    Chen, Han-Wei
    Han, Yuan-Yuan
    FRONTIERS IN MICROBIOLOGY, 2023, 14