Flow injection amperometric determination of persulfate in cosmetic products using a Prussian Blue film-modified electrode

被引:24
作者
De Oliveira, MF [1 ]
Saczk, AA [1 ]
Neto, JAG [1 ]
Roldan, PS [1 ]
Stradiotto, NR [1 ]
机构
[1] Univ Estadual Paulista, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil
关键词
Prussian Blue film-modified electrode; persulfate; flow injection analysis; amperometry;
D O I
10.3390/s30900371
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection system with a glassy carbon disk electrode modified with Prussian Blue film is proposed for the determination of persulfate in commercial samples of hair bleaching boosters by amperometry. The detection was obtained by chronoamperometric technique and the sample is injected into the electrochemical cell in a wall jet configuration. Potassium chloride at concentration of 0.1 mol L-1 acted as sample carrier at a flow rate of 4.0 mL min(-1) and supporting- electrolyte. For 0.025 V (vs. Ag/AgCl) applied voltage, the proposed system handles ca. 160 samples per hour (1.0 10(-4) - 1.0 10(-3) mol L-1 of persulfate), consuming about 200 muL sample and 11 mg KCl per determination. Typical linear correlations between electrocatalytic current and persulfate concentration was ca. 0.9998. The detection limit is 9.0 10(-5) mol L-1 and the calculated amperometric sensibility 3.6 10(3) muA L mol(-1). Relative standard deviation (n = 12) of a 1.0 10(-4) mol L-1 sample is about 2.2%. The method was applied to persulfate determination in commercial hair-bleaching samples and results are in agreement with those obtained by titrimetry at 95% confidence level and good recoveries (95 - 112%) of spiked samples were found.
引用
收藏
页码:371 / 380
页数:10
相关论文
共 24 条
[1]   Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode [J].
Castro, SSL ;
Balbo, VR ;
Barbeira, PJS ;
Stradiotto, NR .
TALANTA, 2001, 55 (02) :249-254
[2]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[3]   ELECTROCATALYTIC OXIDATION OF ASCORBIC-ACID AT A PRUSSIAN BLUE FILM MODIFIED MICRODISK ELECTRODE [J].
DONG, SJ ;
CHE, GL .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 315 (1-2) :191-199
[4]   SENSING WITH CHEMICALLY AND BIOLOGICALLY MODIFIED CARBON ELECTRODES [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1995, 120 (04) :1029-1045
[5]   FLOW-INJECTION AMPEROMETRIC DETECTION OF HYDRAZINE BY ELECTROCATALYTIC OXIDATION AT A PRUSSIAN BLUE FILM-MODIFIED ELECTRODE [J].
HOU, WY ;
WANG, E .
ANALYTICA CHIMICA ACTA, 1992, 257 (02) :275-280
[6]   The electrocatalytic activity of Prussian blue in hydrogen peroxide reduction studied using a wall-jet electrode with continuous flow [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 456 (1-2) :97-104
[7]   Prussian Blue-based 'artificial peroxidase' as a transducer for hydrogen peroxide detection. Application to biosensors [J].
Karyakin, AA ;
Karyakina, EE .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 57 (1-3) :268-273
[8]   Redox coenzyme functionalization of electrochemically grown Prussian blue films [J].
Komplin, GC ;
Pietro, WJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 30 (03) :173-178
[9]   Electrochemical preparation and characterization of hybrid films composed of Prussian blue type metal hexacyanoferrate and conducting polymer [J].
Kulesza, PJ ;
Miecznikowski, K ;
Malik, MA ;
Galkowski, M ;
Chojak, M ;
Caban, K ;
Wieckowski, A .
ELECTROCHIMICA ACTA, 2001, 46 (26-27) :4065-4073
[10]   Prussian blue-based optical glucose biosensor in flow-injection analysis [J].
Lenarczuk, T ;
Wencel, D ;
Glab, S ;
Koncki, R .