Fourier transform infrared spectroscopy and near infrared spectroscopy for the quantification of defects in roasted coffees

被引:44
|
作者
Craig, Ana Paula [1 ,2 ]
Franca, Adriana S. [3 ]
Oliveira, Leandro S. [1 ,3 ]
Irudayaraj, Joseph [2 ]
Ileleji, Klein [2 ]
机构
[1] Univ Fed Minas Gerais, PPGCA, BR-31270901 Belo Horizonte, MG, Brazil
[2] Purdue Univ, Dept Agr & Biol Engn, W Lafayette, IN 47907 USA
[3] Univ Fed Minas Gerais, DEMEC, BR-31270901 Belo Horizonte, MG, Brazil
关键词
Defective coffee; PLSR; FTIR; NIR; DISCRIMINATION; QUALITY; BEANS; REFLECTANCE; CHEMOMETRICS; FTIR; AUTHENTICATION; IDENTIFICATION; PERFORMANCE; OCHRATOXIN;
D O I
10.1016/j.talanta.2014.11.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The coffee strip-picking harvesting method, preferred in Brazil, results in high percentages of immature and overripe beans, as the fruits in a single tree branch do not reach ripeness at the same time. This practice, together with inappropriate processing and storage conditions, contribute to the production of high amounts of defective coffee beans in Brazil, which upon roasting will impart negative sensory aspects to the beverage. Therefore, the development of analytical methodologies that will enable the discrimination and quantification of defective and non-defective coffees after roasting is rather desirable. Given that infrared spectroscopy has been successfully applied to coffee analysis, the objective of this work was to evaluate and to compare the performances of Fourier transform infrared (FTIR) and near infrared (NIR) spectroscopies for the quantification of defective beans in roasted coffees. Defective and non-defective Arabica coffee beans were manually selected, roasted, ground and sieved. Mixtures of defective and non-defective roasted and ground coffees were produced and analyzed, with % defects ranging from 0% to 30%. FTIR and NIR spectra were recorded, respectively, within a range of 3100-800 cm(-1) and 1200-2400 nm and submitted to mathematical processing. Quantitative models were developed by partial least squares regression (PLSR). Excellent predictive results were obtained indicating that defective coffees could be satisfactorily quantified. The correlation coefficients and the root mean squared errors of validation for the FTIR and NIR models developed to quantify the amount of defective roasted coffees mixed with non-defective ones were, respectively, as high as 0.891 and as low as 0.032, and as high as 0.953 and as low as 0.026. A comparison between the two techniques indicated that NIR provided more robust models. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:379 / 386
页数:8
相关论文
共 50 条
  • [21] Fourier transform infrared (FTIR) spectroscopy
    Berthomieu, Catherine
    Hienerwadel, Rainer
    PHOTOSYNTHESIS RESEARCH, 2009, 101 (2-3) : 157 - 170
  • [22] Fourier transform infrared (FTIR) spectroscopy
    Catherine Berthomieu
    Rainer Hienerwadel
    Photosynthesis Research, 2009, 101 : 157 - 170
  • [23] Quantitative analysis of palm carotene using Fourier transform infrared and near infrared spectroscopy
    Moh, M.H.
    Man, Y.B.Che
    Badlishah, B.S.
    Jinap, S.
    Saad, M.S.
    Abdullah, W.J.W.
    JAOCS, Journal of the American Oil Chemists' Society, 1999, 76 (02): : 249 - 254
  • [24] Quantitative analysis of palm carotene using Fourier transform infrared and near infrared spectroscopy
    Moh, MH
    Man, YBC
    Badlishah, BS
    Jinap, S
    Saad, MS
    Abdullah, WJW
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1999, 76 (02) : 249 - 254
  • [25] Assessment of internal beet quality by NIRS (near infrared spectroscopy) and FTIRS (Fourier transform mid infrared spectroscopy)
    Huijbregts, T
    Heijnen, CJ
    Moulin, B
    Noé, B
    ZUCKERINDUSTRIE, 2006, 131 (01): : 16 - 20
  • [26] Comparison and joint use of near infrared spectroscopy and Fourier transform mid infrared spectroscopy for the determination of wine parameters
    Cuadrado, MU
    de Castro, MDL
    Juan, PMN
    Gómez-Nieto, MA
    TALANTA, 2005, 66 (01) : 218 - 224
  • [27] Fourier Transform Infrared Spectroscopy: An analytical technique for microplastic identification and quantification
    Andoh, Collins Nana
    Attiogbe, Francis
    Ackerson, Nana Osei Bonsu
    Antwi, Mary
    Adu-Boahen, Kofi
    INFRARED PHYSICS & TECHNOLOGY, 2024, 136
  • [28] Heavy Mineral Identification and Quantification Using Fourier Transform Infrared Spectroscopy
    Azzam, Fares
    Blaise, Thomas
    Barbarand, Jocelyn
    Cassagne, Helene
    Nouet, Julius
    APPLIED SPECTROSCOPY, 2025,
  • [29] Quantification of erythromycin in pharmaceutical formulation by transmission Fourier transform infrared spectroscopy
    Ali, M.
    Sherazi, S. T. H.
    Mahesar, S. A.
    ARABIAN JOURNAL OF CHEMISTRY, 2014, 7 (06) : 1104 - 1109
  • [30] Mid infrared spectroscopy and chemometrics as tools for the classification of roasted coffees by cup quality
    Craig, Ana Paula
    Botelho, Bruno G.
    Oliveira, Leandro S.
    Franca, Adriana S.
    FOOD CHEMISTRY, 2018, 245 : 1052 - 1061