Functional and Cosmetic Outcome after Reconstruction of Isolated, Unilateral Orbital Floor Fractures (Blow-Out Fractures) with and without the Support of 3D-Printed Orbital Anatomical Models

被引:23
作者
Sigron, Guido R. [1 ,2 ]
Barba, Marina [1 ,2 ]
Chammartin, Frederique [3 ]
Msallem, Bilal [1 ,2 ]
Berg, Britt-Isabelle [1 ]
Thieringer, Florian M. [1 ,2 ]
机构
[1] Univ Hosp Basel, Dept Oral & Cranio Maxillofacial Surg, CH-4031 Basel, Switzerland
[2] Univ Basel, Dept Biomed Engn, Med Addit Mfg Res Grp Swiss MAM, CH-4123 Allschwil, Switzerland
[3] Univ Basel, Univ Hosp Basel, Basel Inst Clin Epidemiol & Biostat, Dept Clin Res, CH-4031 Basel, Switzerland
关键词
orbital fracture; blow-out fracture; orbital reconstruction; functional outcome; patient-specific implant; printed anatomical model; TITANIUM MESH; WALL DEFECTS; IMPLANTS; SURGERY; REPAIR; BIOMATERIALS; MANAGEMENT; BENEFITS;
D O I
10.3390/jcm10163509
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The present study aimed to analyze if a preformed "hybrid" patient-specific orbital mesh provides a more accurate reconstruction of the orbital floor and a better functional outcome than a standardized, intraoperatively adapted titanium implant. Thirty patients who had undergone surgical reconstruction for isolated, unilateral orbital floor fractures between May 2016 and November 2018 were included in this study. Of these patients, 13 were treated conventionally by intraoperative adjustment of a standardized titanium mesh based on assessing the fracture's shape and extent. For the other 17 patients, an individual three-dimensional (3D) anatomical model of the orbit was fabricated with an in-house 3D-printer. This model was used as a template to create a so-called "hybrid" patient-specific titanium implant by preforming the titanium mesh before surgery. The functional and cosmetic outcome in terms of diplopia, enophthalmos, ocular motility, and sensory disturbance trended better when "hybrid" patient-specific titanium meshes were used but with statistically non-significant differences. The 3D-printed anatomical models mirroring the unaffected orbit did not delay the surgery's timepoint. Nonetheless, it significantly reduced the surgery duration compared to the traditional method (58.9 (SD: 20.1) min versus 94.8 (SD: 33.0) min, p-value = 0.003). This study shows that using 3D-printed anatomical models as a supporting tool allows precise and less time-consuming orbital reconstructions with clinical benefits.
引用
收藏
页数:12
相关论文
共 39 条
[1]   Retrobulbar haematoma in the era of anticoagulants [J].
Berg, Britt-Isabelle ;
Flury, Emanuel ;
Thieringer, Florian M. ;
Augello, Marcello ;
Savic, Miodrag ;
Schoetzau, Andreas ;
Kunz, Christoph ;
Goldblum, David .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (10) :1641-1648
[2]   Clinical recommendations for repair of isolated orbital floor fractures - An evidence-based analysis [J].
Burnstine, MA .
OPHTHALMOLOGY, 2002, 109 (07) :1207-1210
[3]   Controversies in orbital reconstruction-III. Biomaterials for orbital reconstruction: a review with clinical recommendations [J].
Dubois, L. ;
Steenen, S. A. ;
Gooris, P. J. J. ;
Bos, R. R. M. ;
Becking, A. G. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (01) :41-50
[4]   Use of nonresorbable alloplastic implants for internal orbital reconstruction [J].
Ellis, E ;
Messo, E .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (07) :873-881
[5]   Assessment of internal orbital reconstructions for pure blowout fractures: Cranial bone grafts versus titanium mesh [J].
Ellis, E ;
Tan, YH .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (04) :442-453
[6]   AN ANALYSIS OF 2,067 CASES OF ZYGOMATICO-ORBITAL FRACTURE [J].
ELLIS, E ;
ELATTAR, A ;
MOOS, KF .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1985, 43 (06) :417-428
[7]   An opinion survey of reported benefits from the use of stereolithographic models [J].
Erickson, DM ;
Chance, D ;
Schmitt, S ;
Mathis, J .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (09) :1040-1043
[8]   Clinical outcome of patients with orbital fractures treated with patient specific CAD/CAM ceramic implants - A retrospective study [J].
Falkhausen, Runa ;
Mitsimponas, Konstantinos ;
Adler, Werner ;
Brand, Michael ;
von Wilmowsky, Cornelius .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2021, 49 (06) :468-479
[9]   Clinical effects of 3-D printing-assisted personalized reconstructive surgery for blowout orbital fractures [J].
Fan, Bin ;
Chen, Han ;
Sun, Ying-Jian ;
Wang, Bei-Fen ;
Che, Lin ;
Liu, Shu-Yan ;
Li, Guang-Yu .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (10) :2051-2057
[10]   CORRECTION OF POSTTRAUMATIC ORBITAL DEFORMITIES - OPERATIVE TECHNIQUES AND REVIEW OF 26 PATIENTS [J].
HAMMER, B ;
PREIN, J .
JOURNAL OF CRANIO-MAXILLO-FACIAL SURGERY, 1995, 23 (02) :81-90