The impacts of dose rate in sliding window intensity modulated radiation therapy quality assurance

被引:1
|
作者
Gul, O., V [1 ]
Inan, G. [1 ]
机构
[1] Selcuk Univ, Fac Med, Dept Radiat Oncol, Konya, Turkey
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2021年 / 19卷 / 03期
关键词
Dose rate; epid; epiqa; 2D array; IMRT; IMRT; DELIVERY; VERIFICATION; RADIOTHERAPY; ACCURACY; CANCER;
D O I
10.18869/acadpub.ijrr.19.3.625
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The present study aims to compare the impacts of dose rate in intensity-modulated radiation therapy (IMRT) plan delivery by using the gamma agreement between the calculated and measured doses by pretreatment quality assurance (QA). Materials and Methods: Ten nasopharynx cancer patients who underwent IMRT treatment were included in this study. The treatment plans were performed using Varian DHX eclipse treatment planning system (TPS) version 15.1. and the QA plans were generated for the dose rates of 300, 400, 500 and 600 MU/min. All measurements were performed by aS1000 Electronic Portal Imaging Device (Epid) integrated into Varian DHX linear accelerator and 2D array detector. The dose distribution was evaluated with gamma area histograms (GAHs) generated using different gamma criteria (2%/2 mm and 3%/3 mm) for dose agreement and distance to agreement parameters. Statistical analyses were evaluated by using Mann-Whitney Test and a p-value of p <0.05 was considered to be significant. Results: There was a significant decrease in the percentage gamma pass rate when the dose rate was increased from 300 MU/min to 600 MU/min (p<0.05). There was a significant difference between Epid and Epiqa for all dose rates (p<0.05). The total number of MU was correlated to the dose rate. When comparing MU from 300 MU/min to 600 MU/min dose rate, it was observed that the MU of IMRT plans increaed as the dose rate was increased. Conclusion: In this study, we have demonstrated that IMRT delivery using sliding window method is affected by the dose rate.
引用
收藏
页码:625 / 632
页数:8
相关论文
共 50 条
  • [1] Evaluation criteria for film based intensity modulated radiation therapy quality assurance
    Anjum, Muhammad Naeem
    Parker, William
    Ruo, Russell
    Afzal, Muhammad
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2010, 26 (01): : 38 - 43
  • [2] On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions
    Day, R. A.
    Sankar, A. P.
    Nailon, W. H.
    MacLeod, A. S.
    MEDICAL PHYSICS, 2011, 38 (02) : 632 - 645
  • [3] Quality assurance of intensity modulated radiation therapy treatment planning using head and neck phantom
    Zahra
    Rehman, Jalil ur
    Asghar, H. M. Noor ul Huda Khan
    Ahmad, Nisar
    Gilani, Zaheer Abbas
    Nasar, Gulfam
    Akhter, Malik M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (03) : 239 - 245
  • [4] A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy
    Son, Jaeman
    Baek, Taesung
    Lee, Boram
    Shin, Dongho
    Park, Sung Yong
    Park, Jeonghoon
    Lim, Young Kyung
    Lee, Se Byeong
    Kim, Jooyoung
    Yoon, Myonggeun
    RADIOLOGY AND ONCOLOGY, 2015, 49 (03) : 307 - 313
  • [5] Strategies for quality assurance of intensity modulated radiation therapy
    Benedek, Hunor
    Isacsson, Ulf
    Olevik-Dunder, Maria
    Westermark, Mathias
    Hallstrom, Per
    Olofsson, Jorgen
    Gustafsson, Magnus
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [6] Comparison of film dosimetry techniques used for quality assurance of intensity modulated radiation therapy
    Ju, Sang Gyu
    Han, Youngyih
    Kum, Oyeon
    Cheong, Kwang-Ho
    Shin, Eun Hyuk
    Shin, Jung Suk
    Kim, Jin Sung
    Ahn, Yong Chan
    MEDICAL PHYSICS, 2010, 37 (06) : 2925 - 2933
  • [7] Comparison of Error Range of Delivery Quality Assurance by Type of Intensity Modulated Radiation Therapy
    Kim, Jeong Ho
    Yoo, Se Jong
    JOURNAL OF MAGNETICS, 2018, 23 (04) : 587 - 595
  • [8] Quality assurance of helical tomotherapy intensity modulated radiation therapy
    Xu, Shouping
    Deng, Xiaowu
    Dai, Xiangkun
    Wang, Lianyuan
    Wang, Yunlai
    Xie, Chuanbin
    Ge, Ruigang
    Gong, Hanshun
    APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 447 - +
  • [9] Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy
    Tsai, Jen-San
    Micaily, Bizhan
    Miyamoto, Curtis
    MEDICAL DOSIMETRY, 2012, 37 (03) : 321 - 333
  • [10] Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments
    Mancuso, Gordon M.
    Fontenot, Jonas D.
    Gibbons, John P.
    Parker, Brent C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4378 - 4385