Fluorescence determination of N-acetylaspartic acid in the rat cerebrum homogenate using high-performance liquid chromatography with pre-column fluorescence derivatization

被引:9
作者
Fukushima, Takeshi [1 ]
Arai, Kotaro [1 ]
Tomiya, Masayuki [1 ]
Mitsuhashi, Shogo [1 ]
Sasaki, Tsukasa [1 ]
Santa, Tomofumi [2 ]
Imai, Kazuhiro [3 ]
Toyo'oka, Toshimasa [1 ]
机构
[1] Univ Shizuoka, Sch Pharmaceut Sci, Div Bioanalyt Chem, Suruga Ku, Shizuoka 4228526, Japan
[2] Univ Tokyo, Grad Sch Pharmaceut Sci, Dept Bioanalyt Chem, Tokyo 1130033, Japan
[3] Musashino Univ, Res Inst Pharmaceut Sci, Tokyo 2028585, Japan
关键词
N-Acetyl-L-aspartic acid; HPLC; DBD-ED; rat cerebrum homogenate; fluorescence detection;
D O I
10.1002/bmc.902
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
N-Acetyl-L-aspartic acid (NAA) is an endogenous compound, and its brain concentration is suggested to be altered in neurological disorders. In the present study, a fluorescence determination method for NAA was developed by employing reversed-phase high-performance liquid chromatography (HPLC) with pre-column fluorescence derivatization using 4-N,N-dimethylaminosulfonyl-7-N-(2-aminoethyl)amino-2,1,3-benzoxadiazole (DBD-ED). Using methylsuccinic acid as the internal standard, a linear calibration curve for NAA was constructed in the range 125-1000 mu m (n = 3). The detection limit on the column was approximately 5.0 fmol (signal-to-noise ratio 3). The proposed HPLC method was applied to determine NAA in the rat cerebrum homogenate. Cerebrum NAA was successfully determined using 10 mu L of the homogenate, and the validation data for the proposed HPLC method demonstrated satisfactory results. Intra- and inter-day precision and accuracy were within 1.1-7.0 and -8.1-6.3%, respectively. The concentration of NAA in the male rat cerebrum (13 weeks old) was 84 +/- 4.6 mu mol/mg protein (n 3). Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
[31]   Quantification of Lipopeptides Using High-performance Liquid Chromatography with Fluorescence Detection after Derivatization [J].
Meng, Yong ;
Liu, Jin-Feng ;
Yang, Shi-Zhong ;
Ye, Ru-Qiang ;
Mu, Bo-Zhong .
ANALYTICAL SCIENCES, 2015, 31 (05) :377-382
[32]   Quantification of Lipopeptides Using High-performance Liquid Chromatography with Fluorescence Detection after Derivatization [J].
Yong Meng ;
Jin-Feng Liu ;
Shi-Zhong Yang ;
Ru-Qiang Ye ;
Bo-Zhong Mu .
Analytical Sciences, 2015, 31 :377-382
[33]   Determination of Sparfloxacin in Human Urine by Reversed-Phase High Performance Liquid Chromatography With Nitrous Acid and Hydroiodic Pre-Column Derivatization [J].
Li Ming DU Zhe Feng FAN Jin Li QIAO Jing Ping WANG Analysis and Test Center Shanxi Teachers University Lingfen Department of Chemistry Arts and Sciences College Taiyuan University of Technology Taiyuan .
ChineseChemicalLetters, 2001, (11) :1007-1010
[34]   Determination of sparfloxacin in human urine by reversed-phase high performance liquid chromatography with nitrous acid and hydroiodic pre-column derivatization [J].
Du, LM ;
Fan, ZF ;
Qiao, JL ;
Wang, JP .
CHINESE CHEMICAL LETTERS, 2001, 12 (11) :1007-1010
[35]   Determination of fatty acids by high-performance liquid chromatography and fluorescence detection using precolumn derivatization with 9-fluorenylmethyl chloroformate [J].
Majnooni, Mohammad Bagher ;
Mohammadi, Bahareh ;
Jalili, Ronak ;
Babaei, Atefeh ;
Bahrami, Gholamreza .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2016, 39 (19-20) :877-881
[36]   High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat [J].
Hami, Zahra ;
Amini, Mohsen ;
Kiani, Amir ;
Ghazi-Khansari, Mahmoud .
IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2013, 12 (04) :911-916
[37]   Determination of sulphonamides in animal tissues by high performance liquid chromatography with pre-column derivatization of 9-fluorenylmethyl chloroformate [J].
Zou, Giong-Hui ;
Xie, Meng-Xia ;
Wang, Xiang-Feng ;
Liu, Yuan ;
Wang, Jin ;
Song, Jia ;
Gao, Hui ;
Han, Jie .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (16) :2647-2655
[38]   Determination of total retronecine esters-type hepatotoxic pyrrolizidine alkaloids in plant materials by pre-column derivatization high-performance liquid chromatography [J].
Xiong, Ai-zhen ;
Yang, Li ;
Zhang, Fang ;
Yang, Xue-jing ;
Wang, Chang-hong ;
Wang, Zheng-tao .
BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (06) :665-671
[39]   Development and validation of a high-performance liquid chromatography method for determination of ractopamine residue in pork samples by solid phase extraction and pre-column derivatization [J].
Ding, Guanglong ;
Li, Deguang ;
Qin, Jiao ;
Zhu, Juanli ;
Wang, Baitao ;
Geng, Qianqian ;
Guo, Mingcheng ;
Punyapitak, Darunee ;
Cao, Yongsong .
MEAT SCIENCE, 2015, 106 :55-60
[40]   Determination of aristolochic acid I in rat urine and plasma by high-performance liquid chromatography with fluorescence detection [J].
Yue, Hao ;
Chan, Wan ;
Guo, Lin ;
Cai, Zongwei .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (10) :995-999