Clinical and radiographic results of total hip arthroplasty after a minimum follow-up period of 5 years after insertion of a TriLock bone preservation stem

被引:0
作者
Tsubosaka, Masanori [1 ]
Hayashi, Shinya [1 ]
Hashimoto, Shingo [1 ]
Takayama, Koji [1 ]
Kuroda, Ryosuke [1 ]
Matsumoto, Tomoyuki [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Orthopaed Surg, Kobe, Hyogo, Japan
来源
ACTA ORTHOPAEDICA BELGICA | 2021年 / 87卷 / ES1期
关键词
total hip arthroplasty; TriLock BPS; mid-term clinical results; Dorr types; FIXATION; COMPONENT; 10-YEAR; CEMENT;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The TriLock bone preservation stem (BPS) is a device that allows proximal fixation of the implant in total hip arthroplasty (THA). The purpose of this study was to evaluate the mid-term clinical and radiographic results of the TriLock BPS and investigate the differences in the results as a function of medullary cavity shape. This study analyzed 76 consecutive patients (62 women and 14 men) who underwent THA using the TriLock BPS between April 2012 and September 2013. The minimum clinical and radiographic followup period for patients was 5 years (mean, 5.6 years). The radiographic results and Harris Hip Scores (HHS) were evaluated across the three Dorr femoral bone classifications. The postoperative HHSs were significantly higher than the preoperative HHSs (p<0.05). There were no significant differences with respect to the three Dorr types based on preoperative and postoperative HHS scores. Stress shielding was observed in 66 hips. Spot welds and cortical hypertrophy were observed in various zones of 31 and 18 hips, respectively. There was no significant difference in the occurrence of stress shielding, spot welds, or cortical hypertrophy among the three Dorr types. There were no complications across all cases during the follow-up period. Mid-term clinical results were good regardless of the medullary cavity shape. Furthermore, the occurrence of stress shielding, spot welds, and cortical hypertrophy was not significantly different among the three Dorr types. Therefore, the TriLcok BPS is a surgical option, regardless of the type of medullary cavity shape, for primary THA.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 21 条
[1]   Favorable Results of a Short, Tapered, Highly Porous, Proximally Coated Cementless Femoral Stem at a Minimum 4-Year Follow-Up [J].
Albers, Anthony ;
Aoude, Ahmed A. ;
Zukor, David J. ;
Huk, Olga L. ;
Antoniou, John ;
Tanzer, Michael .
JOURNAL OF ARTHROPLASTY, 2016, 31 (04) :824-829
[2]   A femoral component inserted without cement in total hip arthroplasty - A study of the Tri-Lock component with an average ten-year duration of follow-up [J].
Burt, CF ;
Garvin, KL ;
Otterberg, ET ;
Jardon, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07) :952-960
[3]  
CHARNLEY J, 1961, LANCET, V1, P1129
[4]  
Charnley J., 1979, LOW FRICTION ARTHROP
[5]   STRUCTURAL AND CELLULAR ASSESSMENT OF BONE QUALITY OF PROXIMAL FEMUR [J].
DORR, LD ;
FAUGERE, MC ;
MACKEL, AM ;
GRUEN, TA ;
BOGNAR, B ;
MALLUCHE, HH .
BONE, 1993, 14 (03) :231-242
[6]  
Dorr LD, 1986, TECH ORTHOP, V1, P22, DOI [10.1097/00013611-198610000-00007, DOI 10.1097/00013611-198610000-00007]
[7]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[8]  
ENGH CA, 1990, CLIN ORTHOP RELAT R, P107
[9]   Cementless Tapered Wedge Femoral Stems Decrease Subsidence in Obese Patients Compared to Traditional Fit-and-Fill Stems [J].
Grant, Tanner W. ;
Lovro, Luke R. ;
Licini, David J. ;
Warth, Lucian C. ;
Ziemba-Davis, Mary ;
Meneghini, Robert M. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (03) :891-897