Interference in the indirect antiglobulin test and direct antiglobulin test from rheumatoid factor

被引:2
|
作者
Xu, Lei [1 ]
Li, Hao [2 ]
Yang, Sishi [1 ]
Zeng, Wenjuan [1 ]
Gan, Shan [2 ]
Chen, Xin [2 ]
Duan, Ling [2 ]
Hu, Hongbing [2 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Dept Lab Med, Wuhan, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Med Coll, Wuhan Childrens Hosp, Dept Blood Transfus, Wuhan, Hubei, Peoples R China
关键词
Indirect antiglobulin test; direct antiglobulin test; rheumatoid factor; interference; red blood cell; immunoassay; SERUM;
D O I
10.1177/0300060519892386
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background The indirect antiglobulin test (IAT) and direct antiglobulin test (DAT) have been used as common tests for transfusion. Recently, we have found that in addition to causing false increases, rheumatoid factor (RF) can also cause false decreases in immunoassays for hepatitis B surface antigen and B-type natriuretic peptide. However, it remains unclear whether RF also interferes with the IAT and DAT. Methods IAT models were produced by mixing IAT-positive plasma and RF-positive plasma, then one-step and two-step IATs were adopted for detection. DAT models were produced by mixing DAT-positive red blood cells (RBCs) and RF-positive plasma, followed by detection with the DAT. The DAT models were diluted using the same RF-positive plasma, and the DAT was performed again. Results The rate of decrease of the two-step IAT (40.63%) was significantly higher than that of the one-step IAT (31.51%). Both the rate of decrease (76.67%) and increase (16.67%) of the results of the 60 DAT models were significantly higher than those of the IAT models after two-fold dilution. Conclusions The RF can lead to both false decreases and false increases in IAT and DAT. And the interference effects are related to the RF content relative to the IgG-sensitized RBCs.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Detection of irregular antibodies by indirect antiglobulin test: comparison with polyspecific reagent and anti-IgG.
    Mannessier, L
    Roubinet, E
    TRANSFUSION CLINIQUE ET BIOLOGIQUE, 1999, 6 (03) : 174 - 179
  • [22] A persistent severe autoimmune hemolytic anemia despite apparent direct antiglobulin test negativization
    Biagi, E
    Assali, G
    Rossi, F
    Jankovic, M
    Nicolini, B
    Balduzzi, A
    HAEMATOLOGICA, 1999, 84 (11) : 1043 - 1045
  • [23] An association between a positive direct antiglobulin test and HLA-DR12 in COVID-19
    Matsuura, Hideaki
    Fujii, Sumie
    Matsui, Yusuke
    Sugiura, Yukari
    Akiyama, Hidehiko
    Miura, Yasuo
    ANNALS OF HEMATOLOGY, 2022, 101 (09) : 1959 - 1969
  • [24] Paper-based assay for red blood cell antigen typing by the indirect antiglobulin test
    Natasha Yeow
    Heather McLiesh
    Liyun Guan
    Wei Shen
    Gil Garnier
    Analytical and Bioanalytical Chemistry, 2016, 408 : 5231 - 5238
  • [25] Bendamustine and Rituximab Treatment, Chronic Lymphocytic Leukemia, Direct Antiglobulin Test, and False Negatives
    Sriwijitalai, Won
    Wiwanitkit, Viroj
    TURKISH JOURNAL OF HEMATOLOGY, 2019, 36 (01) : 53 - 54
  • [26] Prevalence of IgA antired blood cell autoantibodies as observed through direct antiglobulin test
    Moncharmont, P.
    Sanchez, C.
    Dijoux, L.
    Neyraval, N.
    Riga, D.
    IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE, 2008, 23 (01): : 58 - 60
  • [27] Direct antiglobulin test reactive with complement only in warm type autoimmune hemolytic anemia
    Shvidel, L.
    Shtalrid, M.
    Duek, A.
    Haran, M.
    Berrebi, A.
    Sigler, E.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2008, 30 (06) : 494 - 498
  • [28] Does a negative direct antiglobulin test exclude warm autoimmune haemolytic anaemia?: A prospective study of 504 cases
    Sachs, UJH
    Röder, L
    Santoso, S
    Bein, G
    BRITISH JOURNAL OF HAEMATOLOGY, 2006, 132 (05) : 655 - 656
  • [29] Characteristics of Bilirubin According to the Results of the Direct Antiglobulin Test and Its Impact in Hemolytic Disease of the Newborn
    Shin, Kyung-Hwa
    Lee, Hyun-Ji
    Song, Duyeal
    Lee, Sun-Min
    Kim, In Suk
    Kim, Hyunghoi
    Yang, Eu Jeen
    Park, Kyung-Hee
    LABORATORY MEDICINE, 2019, 50 (02) : 138 - 144
  • [30] Positive direct antiglobulin test in COVID-19 patients: Decision-making process
    Cabo, J.
    Brochier, A.
    Saussoy, P.
    Van Dievoet, M-A
    Capirchio, L.
    Delire, B.
    Deneys, V
    TRANSFUSION CLINIQUE ET BIOLOGIQUE, 2021, 28 (04) : 414 - 419