Evaluation of different laser wavelengths on ablation lesion and residual thermal injury in intervertebral discs of the lumbar spine

被引:13
作者
Plapler, Helio [1 ,3 ]
Mancini, Marilia W. [2 ]
Sella, Valeria R. G. [1 ]
Bomfim, Fernando R. C. [1 ]
机构
[1] Univ Fed Sao Paulo, Dept Surg, BR-04023900 Sao Paulo, Brazil
[2] DMC Ltd, BR-13562030 Sao Carlos, SP, Brazil
[3] Rua Tomas Carvalhal,884 Apt 51, BR-04006003 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Intervertebral disc; Nucleotomy; Percutaneous discectomy; Laser surgery; HOLMIUM-YAG LASER; TERM-FOLLOW-UP; DIODE-LASER; DECOMPRESSION PLDD; IN-VIVO; EXPERIENCE; HERNIA; FIBER;
D O I
10.1007/s10103-016-1865-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Laser discectomy or nucleotomy is an increasingly important method for less invasive procedures of column, but the ideal kind of laser is still not established. As the wavelength is an important parameter for water absorption, this study was performed to investigate the action of the laser emission in the near infrared (808 to 1908 nm) region in the context of surgical procedures for percutaneous intervertebral disc decompression (nucleotomy). Forty intervertebral discs from pigs lumbar spines were irradiated with laser (lambda = 808, 980, 1470 and 1908 nm), 1-s on/off time cycles, for 120 cycles and 10 W of power (808, 980, and 1470 nm) or 240 cycles and 5 W of power (1908 nm), with total power of 1200 J, and subjected to microscopic evaluation through hematoxylin-eosin (HE) staining in order to measure the ablation lesions and the residual thermal injury. Ten other discs were not irradiated and worked as controls. The ablation lesions were measured (in mm) at 1.08 +/- 1.25, 1.70 +/- 0.63, 2.23 +/- 1.02, 1.37 +/- 0.39, and 0.94 +/- 0.41 (median +/- SD) for the control, 808, 980, 1470, and 1908 nm groups, respectively. The difference between 1908 nm and all the other groups was statistically significant (p < 0.05). The residual thermal injury was less evident in 1908 nm laser and sharper in 980 nm laser wavelengths. The laser at a wavelength of 1908 nm was considered the most efficient for the vaporization of the nucleus pulposus, followed by the laser wavelengths of 1470, 808, and 980 nm, and proved to be useful for laser nucleotomy procedure.
引用
收藏
页码:421 / 428
页数:8
相关论文
共 34 条
[1]  
Adam D, 2013, CHIRURGIA-BUCHAREST, V108, P94
[2]  
Casper GD, 1996, LASER SURG MED, V19, P90, DOI 10.1002/(SICI)1096-9101(1996)19:1<90::AID-LSM10>3.0.CO
[3]  
2-F
[4]  
Choy D, 2003, PERCUTANEOUS LASER D
[5]  
Choy D S, 1992, J Clin Laser Med Surg, V10, P177
[6]  
Choy D S, 1992, J Clin Laser Med Surg, V10, P435
[7]  
Choy D S, 1995, J Clin Laser Med Surg, V13, P153
[8]   23rd Anniversary of Percutaneous Laser Disc Decompression (PLDD) [J].
Choy, Daniel S. J. ;
Hellinger, Johannes ;
Hellinger, Stefan ;
Tassi, Gian Paolo ;
Lee, Sang-Ho .
PHOTOMEDICINE AND LASER SURGERY, 2009, 27 (04) :535-538
[9]   Percutaneous laser disc decompression: A 17-year experience [J].
Choy, DSJ .
PHOTOMEDICINE AND LASER SURGERY, 2004, 22 (05) :407-410
[10]  
CHOY DSJ, 1987, NEW ENGL J MED, V317, P771