Recommended criteria for the evaluation of bacterial mutagenicity data (Ames test)

被引:59
作者
Levy, Dan D. [1 ]
Zeiger, Errol [2 ]
Escobar, Patricia A. [3 ]
Hakura, Atsushi [4 ]
van der Leede, Bas-jan M. [5 ]
Kato, Masayuki [6 ]
Moore, Martha M. [7 ]
Sugiyama, Kei-ichi [8 ]
机构
[1] US FDA, Ctr Food Safety & Appl Nutr, College Pk, MD 20740 USA
[2] Errol Zeiger Consulting, Chapel Hill, NC 27514 USA
[3] Merck & Co Inc, West Point, PA USA
[4] Eisai & Co Ltd, Tsukuba Drug Safety, Tsukuba, Ibaraki 3002635, Japan
[5] Janssen Res & Dev, Nonclin Safety, Beerse, Belgium
[6] CMIC Pharma Sci Co Ltd, Hokuto, Yamanashi, Japan
[7] Ramboll US Corp, Little Rock, AR 72201 USA
[8] Natl Inst Hlth Sci, Div Genet & Mutagenesis, Kawasaki, Kanagawa 2109501, Japan
关键词
Ames; Regulatory testing; Interpretation criteria; SALMONELLA-TYPHIMURIUM TA102; ASSAYS;
D O I
10.1016/j.mrgentox.2019.07.004
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A committee was constituted within the International Workshop on Genetic Toxicology Testing (IWGT) to evaluate the current criteria for a valid Ames test and to provide recommendations for interpretation of test results. Currently, determination of a positive vs. a negative result is made by applying various data evaluation procedures for comparing dosed plates with the concurrent solvent control plates. These evaluation procedures include a requirement for a specific fold increase (2- or 3-fold, specific to the bacterial strain), formal statistical procedures, or subjective (expert judgment) evaluation. After extensive discussion, the workgroup was not able to reach consensus recommendations in favor of any of these procedures. There was a consensus that combining additional evaluation criteria to the comparison between dosed plates and the concurrent solvent control plates improves test interpretation. The workgroup recommended using these additional criteria because the induction of mutations is a continuum of responses and there is no biological relevance to a strict dividing line between a positive (mutagenic) and not-positive (nonmutagenic) response. The most useful additional criteria identified were a concentration-response relationship and consideration of a possible increase above the concurrent control in the context of the laboratory's historical solvent control values for the particular tester strain. The workgroup also emphasized the need for additional testing to resolve weak or inconclusive responses, usually with altered experimental conditions chosen based on the initial results. Use of these multiple criteria allowed the workgroup to reach consensus on definitions of "clear positive" and "clear negative" responses which would not require a repeat test for clarification. The workgroup also reached consensus on recommendations to compare the responses of concurrent positive and negative controls to historical control distributions for assay acceptability, and the use of control charts to determine the validity of the individual test.
引用
收藏
页数:11
相关论文
共 34 条
[1]   PHENOBARBITAL - DOES THE POSITIVE RESULT IN TA1535 INDICATE GENOTOXIC PROPERTIES [J].
ALBERTINI, S ;
GOCKE, E .
ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 1992, 19 (02) :161-166
[2]   METHODS FOR DETECTING CARCINOGENS AND MUTAGENS WITH SALMONELLA-MAMMALIAN-MICROSOME MUTAGENICITY TEST [J].
AMES, BN ;
MCCANN, J ;
YAMASAKI, E .
MUTATION RESEARCH, 1975, 31 (06) :347-363
[3]  
[Anonymous], 1991, GOOD LAB PRACT IND S
[4]  
[Anonymous], 2011, Preclinical Safety Evaluation of Biotechnology-Derived Pharmaceuticals S6(R1)
[5]   AN EMPIRICAL-APPROACH TO THE STATISTICAL-ANALYSIS OF MUTAGENESIS DATA FROM THE SALMONELLA TEST [J].
BERNSTEIN, L ;
KALDOR, J ;
MCCANN, J ;
PIKE, MC .
MUTATION RESEARCH, 1982, 97 (04) :267-281
[6]   The Ames test: The two-fold rule revisited [J].
Cariello, NF ;
Piegorsch, WW .
MUTATION RESEARCH-GENETIC TOXICOLOGY, 1996, 369 (1-2) :23-31
[7]  
Carries B.A., 1985, MUTAT RES, V147, P15
[8]   REPRODUCIBILITY OF MICROBIAL MUTAGENICITY ASSAYS .1. TESTS WITH SALMONELLA-TYPHIMURIUM AND ESCHERICHIA-COLI USING A STANDARDIZED PROTOCOL [J].
DUNKEL, VC ;
ZEIGER, E ;
BRUSICK, D ;
MCCOY, E ;
MCGREGOR, D ;
MORTELMANS, K ;
ROSENKRANZ, HS ;
SIMMON, VF .
ENVIRONMENTAL MUTAGENESIS, 1984, 6 :1-251
[9]   RECOMMENDATIONS FOR THE PERFORMANCE OF BACTERIAL MUTATION ASSAYS [J].
GATEHOUSE, D ;
HAWORTH, S ;
CEBULA, T ;
GOCKE, E ;
KIER, L ;
MATSUSHIMA, T ;
MELCION, C ;
NOHMI, T ;
OHTA, T ;
VENITT, S ;
ZEIGER, E .
MUTATION RESEARCH, 1994, 312 (03) :217-233
[10]   STATISTICAL CHARACTERIZATION OF NEGATIVE CONTROL DATA IN THE AMES SALMONELLA/MICROSOME TEST [J].
HAMADA, C ;
WADA, T ;
SAKAMOTO, Y .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1994, 102 :115-119