An experimental study was conducted on two pairs of subassemblages of a typical 500 kV transmission tower of the same type as those suffered the most severe damage during ice disaster in South China in 2008. The objectives are to study the failure mechanism of transmission towers under extreme load of freezing rain and to investigate the pertinent retrofitting strategy for increasing the load-carrying capacity of towers so as to prevent their collapse. The difference between specimens in each pair is that one had an additional diaphragm as measures of retrofitting while the other did not. The mechanical behavior, failure mode, strain and deformation at critical points, of the specimens were studied. The test results revealed that buckling of the main leg was the predominant failure mode of structures. For the two subassemblages without diaphragm, the out-of-plane deformations in the joints of diagonal bracings were relatively large and the buckled main angle members exhibited apparent torsion, which significantly decreased the load-carrying capacity of specimens. But for the two subassemblages with diaphragms. the out-of-plane deformations of cross-bracings were markedly inhibited by the added diaphragms and the buckling mode of the main member approached flexural buckling without torsion. As a result, the ultimate strength was increased by 18.3% and 17.6% for the single-panel and double-panel tower subassemblages respectively. It shows that the addition of the diaphragm significantly improved the mechanical performance of transmission towers by reducing the torsional effect on main members and inhibiting the out-of-plane deformation of diagonal braces. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:26 / 36
页数:11
相关论文
共 50 条
  • [41] A Study on the failure mechanism of suction caisson under vertical load
    Jin, Shucheng
    Zhang, Yongtao
    Wu, Qihe
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 1985 - 1989
  • [42] Short-Term Failure Warning for Transmission Tower Under Land Subsidence Condition
    Zhang, Li
    Ruan, Jiangjun
    Du, Zhiye
    Zhou, Wenfeng
    Li, Guannan
    Gan, Yan
    IEEE ACCESS, 2020, 8 : 10455 - 10465
  • [43] Dynamic characteristics of dry-type transmission tower under wind-sand load
    Li, Fule
    Yuan, Binxia
    Dai, Jingjing
    2024 3RD INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING AND APPLIED MECHANICS, ICMEAAE 2024, 2024, 2808
  • [44] Sensitivity of lightning shielding failure of double-circuit transmission line on tower geometric structures
    Li, Zhen
    Yu, Zhanqing
    Wang, Xi
    Peng, Xiangyang
    Li, Zhifeng
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 94 : 86 - 91
  • [45] Eliminating the influence of measuring point failure in ice load identification of polar ship structures
    Wang, Jianwei
    Chen, Xiaodong
    Duan, Qinglin
    Ji, Shunying
    OCEAN ENGINEERING, 2022, 261
  • [46] Probabilistic failure analysis of 400 kV transmission tower-line system subjected to wind and ice hazards
    Mahmoudi, Amir
    Nasrollahzadeh, Kourosh
    Jafari, Mohammad Ali
    WIND AND STRUCTURES, 2021, 33 (03) : 251 - 264
  • [47] Failure probability analysis of transmission towers under ice-wind interaction
    Li J.
    Wang W.
    Fu X.
    Jiang W.
    Dong Z.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2024, 43 (03): : 136 - 146
  • [48] Failure mechanism and invalidation principle of a super-large cooling tower under downburst
    Ke S.-T.
    Li W.-J.
    Han G.-Q.
    Yang J.
    Ren H.-H.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2022, 35 (05): : 1037 - 1047
  • [49] Research on Collapse Mechanism and Failure Criterion of Superlarge Cooling Tower under Downburst Effect
    Li, Wenjie
    Ke, Shitang
    Han, Guangquan
    Yang, Jie
    Ren, Hehe
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (10)
  • [50] The influence of weld joints on the failure mechanism of scaled double hull structures under collision load in finite element simulations
    Werner, Benjamin
    Daske, Christoph
    Heyer, Horst
    Sander, Manuela
    Schoettelndreyer, Martin
    Fricke, Wolfgang
    20TH EUROPEAN CONFERENCE ON FRACTURE, 2014, 3 : 307 - 312