Impact of respiratory motion correction on lesion visibility and quantification in thoracic PET/MR imaging

被引:10
作者
Gratz, Marcel [1 ,2 ]
Ruhlmann, Verena [3 ]
Umutlu, Lale [4 ]
Fenchel, Matthias [5 ]
Hong, Inki [6 ]
Quick, Harald H. [1 ,2 ]
机构
[1] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
[2] Univ Duisburg Essen, High Field & Hybrid MR Imaging, Essen, Germany
[3] Univ Hosp Essen, Dept Nucl Med, Essen, Germany
[4] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
[5] Siemens Healthcare GmbH, Erlangen, Germany
[6] Siemens Med Solut Inc, Knoxville, TN USA
来源
PLOS ONE | 2020年 / 15卷 / 06期
关键词
WHOLE-BODY PET/MR; ATTENUATION CORRECTION; MRI; COMPENSATION; EXPERIENCE; CARCINOMA;
D O I
10.1371/journal.pone.0233209
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The impact of a method for MR-based respiratory motion correction of PET data on lesion visibility and quantification in patients with oncologic findings in the lung was evaluated. Twenty patients with one or more lesions in the lung were included. Hybrid imaging was performed on an integrated PET/MR system using F-18-FDG as radiotracer. The standard thoracic imaging protocol was extended by a free-breathing self-gated acquisition of MR data for motion modelling. PET data was acquired simultaneously in list-mode for 5-10 mins. One experienced radiologist and one experienced nuclear medicine specialist evaluated and compared the post-processed data in consensus regarding lesion visibility (scores 1-4, 4 being best), image noise levels (scores 1-3, 3 being lowest noise), SUVmean and SUVmax. Motion-corrected (MoCo) images were additionally compared with gated images. Non-motion-corrected free-breathing data served as standard of reference in this study. Motion correction generally improved lesion visibility (3.19 +/- 0.63) and noise ratings (2.95 +/- 0.22) compared to uncorrected (2.81 +/- 0.66 and 2.95 +/- 0.22, respectively) or gated PET data (2.47 +/- 0.93 and 1.30 +/- 0.47, respectively). Furthermore, SUVs (mean and max) were compared for all methods to estimate their respective impact on the quantification. Deviations of SUVmax were smallest between the uncorrected and the MoCo lesion data (average increase of 9.1% of MoCo SUVs), while SUVmean agreed best for gated and MoCo reconstructions (MoCo SUVs increased by 1.2%). The studied method for MR-based respiratory motion correction of PET data combines increased lesion sharpness and improved lesion activity quantification with high signal-to-noise ratio in a clinical setting. In particular, the detection of small lesions in moving organs such as the lung and liver may thus be facilitated. These advantages justify the extension of the PET/MR imaging protocol by 5-10 minutes for motion correction.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] MR-assisted PET respiratory motion correction using deep-learning based short-scan motion fields
    Chen, Sihao
    Fraum, Tyler J.
    Eldeniz, Cihat
    Mhlanga, Joyce
    Gan, Weijie
    Vahle, Thomas
    Krishnamurthy, Uday B.
    Faul, David
    Gach, H. Michael
    Binkley, Michael M.
    Kamilov, Ulugbek S.
    Laforest, Richard
    An, Hongyu
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) : 676 - 690
  • [22] Motion correction for PET data using subspace-based real-time MR imaging in simultaneous PET/MR
    Marin, Thibault
    Djebra, Yanis
    Han, Paul K.
    Chemli, Yanis
    Bloch, Isabelle
    El Fakhri, Georges
    Ouyang, Jinsong
    Petibon, Yoann
    Ma, Chao
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [23] PET respiratory motion correction: quo vadis?
    Lamare, F.
    Bousse, A.
    Thielemans, K.
    Liu, C.
    Merlin, T.
    Fayad, H.
    Visvikis, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (03)
  • [24] Characterization of the impact to PET quantification and image quality of an anterior array surface coil for PET/MR imaging
    Scott D. Wollenweber
    Gaspar Delso
    Timothy Deller
    David Goldhaber
    Martin Hüllner
    Patrick Veit-Haibach
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 149 - 159
  • [25] Motion Correction and Attenuation Correction for Respiratory Gated PET Images
    Bai, Wenjia
    Brady, Michael
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 351 - 365
  • [26] Do carotid MR surface coils affect PET quantification in PET/MR imaging?
    Martin J Willemink
    Mootaz Eldib
    Tim Leiner
    Zahi A Fayad
    Venkatesh Mani
    EJNMMI Physics, 2 (Suppl 1)
  • [27] Almost 10 years of PET/MR attenuation correction: the effect on lesion quantification with PSMA: clinical evaluation on 200 prostate cancer patients
    Borjana Bogdanovic
    Andrei Gafita
    Sylvia Schachoff
    Matthias Eiber
    Jorge Cabello
    Wolfgang A. Weber
    Stephan G. Nekolla
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 543 - 553
  • [28] Motion estimation and correction for simultaneous PET/MR using SIRF and CIL
    Brown, Richard
    Kolbitsch, Christoph
    Delplancke, Claire
    Papoutsellis, Evangelos
    Mayer, Johannes
    Ovtchinnikov, Evgueni
    Pasca, Edoardo
    Neji, Radhouene
    Costa-luis, Casper da
    Gillman, Ashley G.
    Ehrhardt, Matthias J.
    McClelland, Jamie R.
    Eiben, Bjoern
    Thielemans, Kris
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2021, 379 (2204):
  • [29] MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging
    Petibon, Y.
    Sun, T.
    Han, P. K.
    Ma, C.
    El Fakhri, G.
    Ouyang, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19)
  • [30] Characterization of the impact to PET quantification and image quality of an anterior array surface coil for PET/MR imaging
    Wollenweber, Scott D.
    Delso, Gaspar
    Deller, Timothy
    Goldhaber, David
    Huellner, Martin
    Veit-Haibach, Patrick
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (02) : 149 - 159