Articular contact vs. embedding: Effect of simplified boundary conditions on the stress distribution in the distal radius and volar plate implant loading

被引:1
作者
Berger, Laurenz [1 ]
Pahr, Dieter [1 ,2 ]
Synek, Alexander [1 ,3 ]
机构
[1] TU Wien, Inst Lightweight Design & Struct Biomech, Vienna, Austria
[2] Karl Landsteiner Univ Hlth Sci, Div Biomech, Krems, Austria
[3] TU Wien, Gumpendorfer Str 7, E317, A-1060 Vienna, Austria
关键词
Distal radius fracture; Radiocarpal joint; Volar plate; Subchondral bone stress; Finite element; BONE-DENSITY; FRACTURES; COLLES; MODELS; WRIST;
D O I
10.1016/j.jbiomech.2022.111279
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Boundary conditions (BCs) are often simplified in experimental and numerical models simulating distal radius fractures and their treatments. The aim of this study was to investigate the effects of simplified BCs at the radiocarpal joint: (1) on the stress distribution in the intact distal radius, and (2) on the loading of a volar locking plate (VLP) used for distal radius fracture treatment. Finite element models of the distal radius with contact between carpals and cartilage were created as reference models for an intact bone and a fractured bone with VLP treatment. Four models with simplified BCs were compared to these reference models: One with embedding material instead of carpals, one with carpals tied to the radius; each loaded either uniaxially or with statically equivalent loading to the reference model. Differences in distal bone stress distributions and mechanical pa-rameters of the VLP (fracture gap movement, plate peak stresses, distal screw loads) were generally largest for the uniaxially loaded, embedded model (up to 250 % in individual screw loads) and smallest for the model with tied carpals and statically equivalent loads (<25 % for all parameters). Differences were greatly reduced if statically equivalent loads were applied, but subchondral stress peaks were absent without carpals. In conclusion, implementing realistic resultant forces and moments is more important than the exact articular load distribution, but carpal bones should be included if subchondral bone stresses are analyzed. In this case, a tie constraint may replace articular contact modelling with acceptable accuracy if statically equivalent loading is applied.
引用
收藏
页数:7
相关论文
共 27 条
[1]  
ARMSTRONG CG, 1984, J BIOMECH ENG-T ASME, V106, P165, DOI 10.1115/1.3138475
[2]   The influence of distal screw length on the primary stability of volar plate osteosynthesis-a biomechanical study [J].
Baumbach, Sebastian F. ;
Synek, Alexander ;
Traxler, Hannes ;
Mutschler, Wolf ;
Pahr, Dieter ;
Chevalier, Yan .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
[3]   Where Is the Distal Fracture Line Location of Dorsally Displaced Distal Radius Fractures? [J].
Baumbach, Sebastian Felix ;
Schmidt, Reinhard ;
Varga, Peter ;
Heinz, Thomas ;
Vecsei, Vilmos ;
Zysset, Philippe K. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (04) :489-494
[4]   Biomechanical considerations in the design of patient-specific fixation plates for the distal radius [J].
Caiti, G. ;
Dobbe, J. G. G. ;
Bervoets, E. ;
Beerens, M. ;
Strackee, S. D. ;
Strijkers, J. ;
Streekstra, G. J. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (05) :1099-1107
[5]   Subject-specific bone loading estimation in the human distal radius [J].
Christen, Patrik ;
Ito, Keita ;
Knippels, Ingrid ;
Mueller, Ralph ;
van Lenthe, G. Harry ;
van Rietbergen, Bert .
JOURNAL OF BIOMECHANICS, 2013, 46 (04) :759-766
[6]  
de Saint-Venant B., 1855, MEM DIVERS SAVANTS, V14, P233
[7]   More is not necessarily better. A biomechanical study on distal screw numbers in volar locking distal radius plates [J].
Drobetz, Herwig ;
Weninger, Patrick ;
Grant, Caroline ;
Heal, Clare ;
Muller, Reinhold ;
Schuetz, Michael ;
Pham, Minh ;
Steck, Roland .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04) :535-539
[8]   UNEQUAL DECREASE IN BONE-DENSITY OF LUMBAR SPINE AND ULTRADISTAL RADIUS IN COLLES AND VERTEBRAL FRACTURE SYNDROMES [J].
EASTELL, R ;
WAHNER, HW ;
OFALLON, WM ;
AMADIO, PC ;
MELTON, LJ ;
RIGGS, BL .
JOURNAL OF CLINICAL INVESTIGATION, 1989, 83 (01) :168-174
[9]   Finite element prediction of surface strain and fracture strength at the distal radius [J].
Edwards, W. Brent ;
Troy, Karen L. .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (03) :290-298
[10]   Simplified boundary conditions alter cortical-trabecular load sharing at the distal radius; A multiscale finite element analysis [J].
Johnson, Joshua E. ;
Troy, Karen L. .
JOURNAL OF BIOMECHANICS, 2018, 66 :180-185