Recent applications of microchip electrophoresis to biomedical analysis

被引:91
作者
Nuchtavorn, Nantana [1 ,2 ,3 ]
Suntornsuk, Worapot [4 ]
Lunte, Susan M. [5 ]
Suntornsuk, Leena [1 ,5 ,6 ]
机构
[1] Mahidol Univ, Fac Pharm, Dept Pharmaceut Chem, Bangkok 10400, Thailand
[2] Univ Tasmania, Sch Phys Sci, Hobart, Tas 7001, Australia
[3] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
[4] King Mongkuts Univ Technol Thonburi, Fac Sci, Dept Microbiol, Bangkok 10140, Thailand
[5] Univ Kansas, Ralph N Adams Inst Bioanalyt Chem, Lawrence, KS 66046 USA
[6] Mahidol Univ, Fac Pharm, Ctr Excellence Innovat Drug Design & Discovery, Bangkok 10400, Thailand
关键词
Microchip electrophoresis; Capillary electrophoresis; Microfluidics; Biomedical analysis; Bioactive compounds; CAPILLARY GEL-ELECTROPHORESIS; TOTAL ANALYSIS SYSTEMS; INDUCED FLUORESCENCE DETECTION; IONIZATION-MASS-SPECTROMETRY; INTEGRATED MICROFLUIDIC DEVICE; AMPEROMETRIC DETECTION; ON-CHIP; HIGH-SPEED; ELECTROCHEMICAL DETECTION; ZONE-ELECTROPHORESIS;
D O I
10.1016/j.jpba.2015.03.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Many separation methods have been developed for biomedical analysis, including chromatographic (e.g. high performance liquid chromatography (HPLC) and gas chromatography (GC)) and electrophoretic methods (e.g. gel electrophoresis and capillary electrophoresis (CE)). Among these techniques, CE provides advantages in terms of high separation efficiency, simplicity, low sample and solvent volume consumption, short analysis time and applicability to a wide range of biomedically important substances. Microchip electrophoresis (ME) is a miniaturized platform of CE and is now considered as a simpler and more convenient alternative, which has demonstrated potential in analytical chemistry. High-throughput, cost-effective and portable analysis systems can be developed using ME. The current review describes different separation modes and detectors that have been employed in ME to analyze various classes of biomedical analytes (e.g. pharmaceuticals and related substances, nucleic acids, amino acids, peptides, proteins, antibodies and antigens, carbohydrates, cells, cell components and lysates). Recent applications (during 2010-2014) in these areas are presented in tables and some significant findings are highlighted. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 96
页数:25
相关论文
共 259 条
  • [1] Hybrid microfluidics: A digital-to-channel interface for in-line sample processing and chemical separations
    Abdelgawad, Mohamed
    Watson, Michael W. L.
    Wheeler, Aaron R.
    [J]. LAB ON A CHIP, 2009, 9 (08) : 1046 - 1051
  • [2] Enhancement of on chip chemiluminescence signal intensity of tris(1,10-phenanthroline)-ruthenium(II) peroxydisulphate system for analysis of chlorpheniramine maleate in pharmaceutical formulations
    Al Lawati, Haider A. J.
    Suliman, Fakhr Eldin O.
    Al Kindy, Salma M. Z.
    Al-Lawati, Ali M.
    Varma, Gouri B.
    Nour, Imad Eldin M.
    [J]. TALANTA, 2010, 82 (05) : 1999 - 2002
  • [3] Poly (acrylic acid) microchannel modification for the enhanced resolution of catecholamines microchip electrophoresis with electrochemical detection
    Alvarez-Martos, Isabel
    Teresa Fernandez-Abedul, M.
    Anillo, Adela
    Fierro, Jose Luis G.
    Garcia Alonso, Francisco Javier
    Costa-Garcia, Agustin
    [J]. ANALYTICA CHIMICA ACTA, 2012, 724 : 136 - 143
  • [4] A portable lab-on-a-chip instrument based on MCE with dual topbottom capacitive coupled contactless conductivity detector in replaceable cell cartridge
    Ansari, Kambiz
    Ying, Jasmine Yuen Shu
    Hauser, Peter C.
    de Rooij, Nico F.
    Rodriguez, Isabel
    [J]. ELECTROPHORESIS, 2013, 34 (9-10) : 1390 - 1399
  • [5] Use of microchip electrophoresis and a palladium/mercury amalgam electrode for the separation and detection of thiols
    Antwi, Christiana
    Johnson, Alicia S.
    Selimovic, Asmira
    Martin, R. Scott
    [J]. ANALYTICAL METHODS, 2011, 3 (05) : 1072 - 1078
  • [6] Rapid CE microbial assays for consumer products that contain active bacteria
    Armstrong, DW
    Schneiderheinze, JM
    Kullman, JP
    He, LF
    [J]. FEMS MICROBIOLOGY LETTERS, 2001, 194 (01) : 33 - 37
  • [7] A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device
    Arora, A
    Eijkel, JCT
    Morf, WE
    Manz, A
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (14) : 3282 - 3288
  • [8] Micro total analysis systems. 2. Analytical standard operations and applications
    Auroux, PA
    Iossifidis, D
    Reyes, DR
    Manz, A
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2637 - 2652
  • [9] Polymer microfluidic devices
    Becker, H
    Locascio, LE
    [J]. TALANTA, 2002, 56 (02) : 267 - 287
  • [10] Recent advances in polymeric monolithic stationary phases for electrochromatography in capillaries and chips
    Bedair, M
    El Rassi, Z
    [J]. ELECTROPHORESIS, 2004, 25 (23-24) : 4110 - 4119