A Microfluidics-based Pulpal Arteriole Blood Flow Phantom for Validation of Doppler Ultrasound Devices in Pulpal Blood Flow Velocity Measurement

被引:9
|
作者
Kim, Dohyun
Park, Sung-Ho [1 ,2 ]
机构
[1] Yonsei Univ, Coll Dent, Dept Conservat Dent, 50-1 Yonsei Ro, Seoul 03722, South Korea
[2] Yonsei Univ, Coll Dent, Oral Sci Res Ctr, 50-1 Yonsei Ro, Seoul 03722, South Korea
关键词
Doppler ultrasound; flow phantom; microfluidic chip; microfluidics; pulpal blood flow velocity; TEETH;
D O I
10.1016/j.joen.2016.08.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Recently, Doppler ultrasound has been used for the measurement of pulpal blood flow in human teeth. However, the reliability of this method has not been verified. In this study, we developed a model to simulate arteriole blood flow within the dental pulp by using microfluidics. This arteriole simulator, or flow phantom, was used to determine the reliability of measurements obtained by using a Doppler ultrasound device. Methods: A microfluidic chip was fabricated by using. the soft lithography technique, and blood mimicking fluid was pumped through the channel by a microfluidic system. A Doppler ultrasound device was used for the measurement of flow velocity. The peak, mean, and minimal flow velocities obtained from the phantom and the Doppler ultrasound device were Compared by using linear regression analysis and Pear son correlation coefficient. Bland-Altman analyses were performed to evaluate the velocity differences between the flow generated by the phantom and the flow measurements made with the Doppler ultraSound device. Results: The microfluidic system was able to generate the flow profiles as intended, and the fluid flow could be monitored and controlled by the software program. There were excellent linear correlations between the peak, mean, and minimal flow velocities of the phantom and those of the Doppler ultrasound device (r = 0.94-0.996, P < .001). However, the velocities were overestimated by the Doppler ultrasound device: Conclusions: This phantom provides opportunities for research and education involving the Doppler ultrasound technique in dentistry. Although Doppler ultrasound can be an effective tool for the measurement of pulpal blood flow velocity, it is essential to validate and calibrate the device before clinical use. (J Endod 2016;42:1660-1666)
引用
收藏
页码:1660 / 1666
页数:7
相关论文
共 50 条
  • [41] MEASUREMENT OF BLOOD-FLOW WITH DOPPLER ULTRASOUND
    KLEPPER, JR
    MEDICAL PHYSICS, 1986, 13 (04) : 621 - 621
  • [42] Age-related changes of pulpal blood flow in primary teeth measured by laser Doppler blood flowmetry
    Komatsu, Hideji
    Ikawa, Motohide
    Mayanagi, Hideaki
    PEDIATRIC DENTAL JOURNAL, 2007, 17 (01) : 27 - 31
  • [43] Outcomes of dental fracture injury as related to laser Doppler flow measurements of pulpal blood-flow level
    Emshoff, Ruediger
    Moschen, Ivano
    Oberrauch, Andreas
    Gerhard, Stefan
    Strobl, Heinrich
    DENTAL TRAUMATOLOGY, 2008, 24 (04) : 416 - 421
  • [44] Effect of Contrast Agents on Results of Doppler Ultrasound Measurement of Blood Flow Velocity
    Muravieva O.V.
    Bogdan O.P.
    Nafikova S.F.
    Muravieva, O.V. (olgak166@mail.ru), 1600, Springer Science and Business Media, LLC (50): : 44 - 49
  • [45] Comparative evaluation of pulpal blood flow during incisor intrusion
    Sabuncuoglu, Fidan Alakus
    Ersahan, Seyda
    AUSTRALIAN ORTHODONTIC JOURNAL, 2015, 31 (02) : 171 - 177
  • [46] Regulation mechanisms of pulpal blood flow outside the dental pulp
    Takahashi, K
    Sakai, S
    DENTIN/PULP COMPLEX, 1996, : 158 - 161
  • [47] Laser Doppler pulpal blood flow signals from red and infrared light sources.
    Kijsamanmith, K.
    Vongsavan, N.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B48 - B48
  • [48] Pulpal blood-flow characteristics of maxillary tooth morphotypes as assessed with laser Doppler flowmetry
    Norer, B
    Kranewitter, R
    Emshoff, R
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1999, 87 (01): : 88 - 92
  • [49] Age-related changes in the human pulpal blood flow measured by laser Doppler flowmetry
    Ikawa, M
    Komatsu, H
    Ikawa, K
    Mayanagi, H
    Shimauchi, H
    DENTAL TRAUMATOLOGY, 2003, 19 (01) : 36 - 40
  • [50] MEASUREMENT OF PULPAL BLOOD-FLOW IN DOGS WITH THE XE-133 WASHOUT METHOD
    KIM, S
    CHEN, RYZ
    USAMI, S
    JAN, KM
    CHIEN, S
    JOURNAL OF DENTAL RESEARCH, 1981, 60 : 421 - 421