Solid Phase Extraction of Ultra Trace Copper Using Octadecyl Silica Bonded Phase Membrane Disks Modified by a New Symmetric Schiff Base Ionophore Prior to FAAS Determination

被引:4
作者
Mohammadhosseini, Majid [1 ]
Zamani, Hassan A. [2 ]
Hashemi-Moghaddam, Hamid [3 ]
Nekoei, Mehdi [1 ]
Noei-Aghaei, Mohammad A. [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Shahrood Branch, Shahrood, Iran
[2] Islamic Azad Univ, Dept Appl Chem, Quchan Branch, Quchan, Iran
[3] Islamic Azad Univ, Dept Chem, Damghan Branch, Damghan, Iran
关键词
Copper(II); Flame atomic absorption spectrometry; Modifier; N; N '-ethylene bis-(3-formyl-5-methyl salicyl aldymine) (EFMA); Solid phase extraction; ATOMIC-ABSORPTION-SPECTROMETRY; OPTICAL-EMISSION-SPECTROMETRY; WATER SAMPLES; AQUEOUS SAMPLES; PRECONCENTRATION; LEAD; IONS; ENRICHMENT; ELEMENTS; SEPARATION;
D O I
10.2174/157341111797183092
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very selective, reliable and precise method for rapid separation of the trace amounts of copper in aqueous samples using octadecyl silica bonded phase membrane disks modified by N,N'-ethylene-bis-(3-formyl-5-methyl salicyl aldymine) combined with flame atomic absorption spectrometric determination has been established. All the affecting experimental variables such as pH, amount of modifier, eluent type, sample and eluent flow-rate, foreign ions and disk capacity were also investigated. The target analyte (trace copper) was quantitatively retained at pH=4, and eluted with 8 mL of HCl (1M) and HNO3 0.5 M each containing 2.0% (v/v) methanol applying flow rates of 50 mL min(-1) and 15 mL min(-1) for sample introduction and elution steps, respectively. The proposed method exhibits a wide linear dynamic range over 5-150 ng mL(-1) and reproducibility at the most 3%. It also permits an enrichment factor of about 400 or higher and a detection limit of 0.005 ng mL(-1). The method has been successfully applied for isolation and determination of copper in different aqueous, real samples, peppers and standard alloys.
引用
收藏
页码:306 / 317
页数:12
相关论文
共 50 条
[41]   Solid phase extraction of copper traces using poly(styrene-divinylbenzene) membrane disks modified with pyridoxal salicyloylhydrazone in water samples [J].
Diaz-de Alba, M. ;
Galindo-Riano, M. D. ;
Garcia-Vargas, M. .
TALANTA, 2012, 100 :432-438
[42]   Solid phase extraction of uranium and thorium on octadecyl bonded silica modified with Cyanex 302 from aqueous solutions [J].
Nilchi, A. ;
Dehaghan, T. Shariati ;
Garmarodi, S. Rasouli .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 295 (03) :2111-2115
[43]   Ultra-trace monitoring of copper in environmental and biological samples by inductively coupled plasma atomic emission spectrometry after separation and preconcentration by using octadecyl silica membrane disks modified by a new Schiff's base [J].
Ganjali, MR ;
Pourjavid, MR ;
Babaei, LHA ;
Salavati-Niasari, M .
QUIMICA NOVA, 2004, 27 (02) :213-217
[44]   Determination of Copper in Water Samples after Solid-phase Extraction Using Dimethylglyoxime-modified Silica [J].
Anilan, Burcu ;
Gedikbey, Tevfik ;
Akar, Sibel Tunali .
CLEAN-SOIL AIR WATER, 2010, 38 (04) :344-352
[45]   PRECONCENTRATION OF COPPER FROM NATURAL WATER SAMPLES USING LIGAND-LESS IN SITU SURFACTANT-BASED SOLID PHASE EXTRACTION PRIOR TO FAAS DETERMINATION [J].
Mohammadi, Sayed Zia ;
Afzali, Daryoush ;
Sabermahani, Fatemeh ;
Afshari, Samira .
QUIMICA NOVA, 2014, 37 (09) :1436-1440
[46]   Determination of trace amounts of copper and lead in water, environmental and biological samples by atomic absorption spectrometry after their separation and preconcentration by using modified octadecyl silica membrane disks [J].
Ganjali, MR ;
Basiripour, F ;
Salavati-Niasari, M .
CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2002, 47 (02) :41-48
[47]   Flame atomic absorption spectrometric determination of trace amounts of silver in aqueous sample after solid phase extraction using octadecyl silica membrane disks modified by 2-[(2-mercapt ophenyliminio)methyl]phenol [J].
Shabani, A. M. Haji ;
Dadfarnia, S. ;
Jafari, A. A. ;
Shahbasi, Z. .
CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (04) :194-199
[48]   Determination of Trace Amount of Cadmium by Atomic Absorption Spectrometry in Table Salt after Solid Phase Preconcentration Using Octadecyl Silica Membrane Disk Modified by a New Derivative of Pyridine [J].
Payehghadr, Mahmood ;
Esmaeilpour, Sousan ;
Rofouei, Mohammad Kazem ;
Adlnasab, Laleh .
JOURNAL OF CHEMISTRY, 2013, 2013
[49]   Solid phase extraction of Pb(II) in water samples using a new hybrid inorganic-organic mesoporous silica prior to its determination by FAAS [J].
Damián Pérez-Quintanilla ;
Alfredo Sánchez ;
Isabel del Hierro ;
Mariano Fajardo ;
Isabel Sierra .
Microchimica Acta, 2009, 165 :291-298
[50]   Determination of Trace Copper in Drinking Water by Flame Atomic Absorption Spectrometry After Solid Phase Extraction on Polymer Modified Silica Gel [J].
Chen, Jing ;
Wang, Ning ;
Li, Bo ;
Wan, Dongjin ;
Sun, Xuzhuo .
ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (16) :9041-9044