Behavior and performance of cold-formed steel-framed houses under seismic action

被引:65
|
作者
Dubina, Dan [1 ]
机构
[1] Politehn Univ Timisoara, Dept Steel Struct & Struct Mech, Timisoara 300224, Romania
关键词
light-gauge steel houses; seismic action; performance-based design;
D O I
10.1016/j.jcsr.2008.01.029
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years important research activity has been undertaken in order to evaluate the earthquake performance of light-gauge steel-framed house structures. Almost all studies approach the problem of seismic response of these structures by characterising, experimentally and numerically, the performance of wall panels. Usually, the overall behavior of wall panels is mainly addressed. However, according to experimental evidences, the performance of the wall panels, as a whole, is governed by the performance of the connectors e.g.: sheeting-to-sheeting connectors, and sheeting-to-framing connectors. On the other hand the global behavior of the 3D structure of the house is significantly influenced by nonstructural elements, traditionally not considered in the design procedures. The present paper summarizes the research activity carried out in the last few years at the Politehnica University of Timisoara, under the coordination of the author, with the aim to evaluate the performance and to characterise for design purpose the specific features of these structures. Monotonic and cyclic tests on full-scale shear panels, tests on connection details, and in situ ambiental vibration tests on a house under construction are reviewed and concluded in the following paper. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:896 / 913
页数:18
相关论文
共 50 条
  • [31] Physical damage-hysteretic response correlation for steel sheet sheathed cold-formed steel-framed wall-lines
    Singh, Amanpreet
    Wang, Xiang
    Zhang, Zhidong
    Peterman, Kara D.
    Schafer, Benjamin W.
    Hutchinson, Tara C.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, 53 (03): : 1195 - 1215
  • [32] Shear behaviour of reinforced straw-bale plaster sheathed cold-formed steel-framed shear walls
    Sun, Huaishuan
    Cao, Baozhu
    Chen, Zhihua
    Du, Yansheng
    BIOSYSTEMS ENGINEERING, 2022, 221 : 54 - 68
  • [33] Design of steel sheathed cold-formed steel framed shear walls
    Balh, N.
    DaBreo, J.
    Ong-Tone, C.
    El-Saloussy, K.
    Yu, C.
    Rogers, C. A.
    THIN-WALLED STRUCTURES, 2014, 75 : 76 - 86
  • [34] Dynamic Testing of Single- and Double-Story Steel-Sheathed Cold-Formed Steel-Framed Shear Walls
    Shamim, Iman
    DaBreo, Jamin
    Rogers, Colin A.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2013, 139 (05): : 807 - 817
  • [35] Seismic Behavior of Cold-Formed Steel Frames with Bolted Moment Connections
    Chen, Ming
    Huo, Jia-Hao
    Xing, Yi-Wen
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (03)
  • [36] Experimental study on seismic performance of two-story walls in ledger-framed cold-formed steel buildings
    Shi Y.
    Han Y.
    Xiao W.
    Yao X.
    Zhang Z.
    Guan Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (02): : 71 - 81
  • [37] Dynamic behaviour of cold-formed steel structures under seismic loads
    Calderoni, B.
    Giubileo, C.
    De Martino, A.
    STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 225 - 230
  • [38] Cold-formed steel framed shear wall test database
    Zhang, Zhidong
    Eladly, Mohammed M.
    Rogers, Colin A.
    Schafer, Benjamin W.
    EARTHQUAKE SPECTRA, 2024, 40 (01) : 871 - 884
  • [39] Behavior of cold-formed steel purlins under gravity loading
    Willis, Christopher T., 1600, (116):
  • [40] BEHAVIOR OF COLD-FORMED STEEL PURLINS UNDER GRAVITY LOADING
    WILLIS, CT
    WALLACE, B
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1990, 116 (08): : 2061 - 2069