Behavior and performance of cold-formed steel-framed houses under seismic action

被引:65
|
作者
Dubina, Dan [1 ]
机构
[1] Politehn Univ Timisoara, Dept Steel Struct & Struct Mech, Timisoara 300224, Romania
关键词
light-gauge steel houses; seismic action; performance-based design;
D O I
10.1016/j.jcsr.2008.01.029
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years important research activity has been undertaken in order to evaluate the earthquake performance of light-gauge steel-framed house structures. Almost all studies approach the problem of seismic response of these structures by characterising, experimentally and numerically, the performance of wall panels. Usually, the overall behavior of wall panels is mainly addressed. However, according to experimental evidences, the performance of the wall panels, as a whole, is governed by the performance of the connectors e.g.: sheeting-to-sheeting connectors, and sheeting-to-framing connectors. On the other hand the global behavior of the 3D structure of the house is significantly influenced by nonstructural elements, traditionally not considered in the design procedures. The present paper summarizes the research activity carried out in the last few years at the Politehnica University of Timisoara, under the coordination of the author, with the aim to evaluate the performance and to characterise for design purpose the specific features of these structures. Monotonic and cyclic tests on full-scale shear panels, tests on connection details, and in situ ambiental vibration tests on a house under construction are reviewed and concluded in the following paper. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:896 / 913
页数:18
相关论文
共 50 条
  • [1] Seismic performance of cold-formed steel framed houses
    Dubina, D.
    Fulop, L. A.
    Aldea, A.
    Demetriu, S.
    Nagy, Zs.
    Stessa 2006, 2006, : 429 - 435
  • [2] Seismic Design Strength of Cold-Formed Steel-Framed Shear Walls
    Serrette, Reynaud
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (09): : 1123 - 1130
  • [3] Analytical Model for the Seismic Performance of Cold-Formed Steel-Framed Gypsum Partition Walls
    Rahmanishamsi, E.
    Soroushian, S.
    Maragakis, E. M.
    Structures Congress 2015, 2015, : 1707 - 1718
  • [4] Lateral performance of cold-formed steel-framed domestic structures
    Univ of Melbourne, Parkville
    Eng Struct, 1 (83-95):
  • [5] Lateral performance of cold-formed steel-framed domestic structures
    Gad, EF
    Duffield, CF
    Hutchinson, GL
    Mansell, DS
    Stark, G
    ENGINEERING STRUCTURES, 1999, 21 (01) : 83 - 95
  • [6] Seismic performance of cold-formed steel framed houses with wall-stud shear walls
    Fülöp, LA
    Dubina, D
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 1359 - 1365
  • [7] Modeling seismic response of a full-scale cold-formed steel-framed building
    Leng, Jiazhen
    Peterman, Kara D.
    Bian, Guanbo
    Buonopane, Stephen G.
    Schafer, Benjamin W.
    ENGINEERING STRUCTURES, 2017, 153 : 146 - 165
  • [8] Analytical model for the in-plane seismic performance of cold-formed steel-framed gypsum partition walls
    Rahmanishamsi, Esmaeel
    Soroushian, Siavash
    Maragakis, Emmanuel M.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (04): : 619 - 634
  • [9] Impact of Wall Configurations on Seismic Fragility of Steel-Sheathed Cold-Formed Steel-Framed Buildings
    Jiang, Liqiang
    Ye, Jihong
    ADVANCES IN CIVIL ENGINEERING, 2018, 2018
  • [10] Evaluation of Seismic Deflection Amplification Factor for Buildings Utilizing Cold-Formed Steel-Framed Shear Walls
    Eladly, Mohammed M.
    Schafer, Benjamin W.
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (07)