Electric Field Computation Under a Double Circuit 380 kV Overhead Transmission Line

被引:0
|
作者
Alshehri, Jaber [1 ]
Alshalawi, Abdulaziz [1 ,2 ]
Khalid, Muhammad [1 ,3 ]
机构
[1] King Fahd Univ Petr & Minerals KFUPM, Elect Engn Dept, Dhahran 31261, Saudi Arabia
[2] Saudi Aramco, Tech Support Dept, Ras Tanura 32819, Saudi Arabia
[3] KA CARE Energy Res & Innovat Ctr, Dhahran 31261, Saudi Arabia
关键词
Charge simulation method (CSM); electric field computation; HVAC overhead transmission lines;
D O I
10.1109/icrera47325.2019.8996514
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In today's world, a growing concern among power utilities' workers regarding the possible health hazards associated with the exposure to the electric field of the HVAC overhead transmission lines. Hence, this paper aims to find the electric field distribution under a 380 kV double circuit overhead transmission line. Each phase has four bundles and arranged in a vertical configuration. The HVAC transmission line is modeled in MATLAB based on actual data for a standard 380 kV overhead transmission line of the Saudi National Grid (NG). Using the charge simulation method (CSM), the electric field exposure level has been computed at three distinct levels under the transmission line. These levels are ground level, head level, and close Maintenance level. The electric field profile for each scenario has been plotted. Finally, the simulation results are compared with the maximum allowable exposure limits defined by three different international standards.
引用
收藏
页码:377 / 380
页数:4
相关论文
共 50 条
  • [41] Phase current asymmetry on the double-circuit very high voltage overhead transmission line
    Nazarcik, Tomas
    Rawn, Barry
    2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 80 - 84
  • [42] Distribution of Magnetic Field in 400 kV Double-Circuit Transmission Lines
    Deltuva, Ramunas
    Lukocius, Robertas
    APPLIED SCIENCES-BASEL, 2020, 10 (09):
  • [43] Electric and magnetic field under various parts of multi-channel overhead power line 400/220/110 kV
    Kasprzak, Wojciech
    Nadolny, Zbigniew
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 170 - 173
  • [44] Electric Field Radiation from an Overhead Transmission Line Located Above a Lossy Ground
    Taheri, Pooya
    Kordi, Behzad
    Gole, Ani M.
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 1041 - 1045
  • [45] PLANNING AND ERECTING A 380-KV-HIGH-VOLTAGE-OVERHEAD-TRANSMISSION-LINE FROM ROHRSDORF TO THE GDR-CSSR BORDER
    BUTTNER, G
    ENERGIETECHNIK, 1981, 31 (01): : 34 - 36
  • [47] Research on induced current and induced voltage of 500 kV double circuit transmission line
    Ren Hongtao
    Zhang Ying
    ENERGY REPORTS, 2021, 7 : 216 - 223
  • [48] Fail ure of 220 kV double circuit transmission line tower due to lightning
    Nair, Z
    Aparna, KM
    Khandagale, RS
    Gopalan, TV
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2005, 19 (02) : 132 - 137
  • [49] Overhead Transmission Line 750 kV Model with Bundle Wire
    Glushkov, Daniil A.
    Zinovev, Kirill A.
    PROCEEDINGS OF THE 2017 IEEE RUSSIA SECTION YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (2017 ELCONRUS), 2017, : 1152 - 1155
  • [50] Analysis on the Electromagnetic Environmental Factors of 500kV Double Circuit Transmission Line
    Qi, Jianzhao
    Li, Jingyi