Electric Field Computation Under a Double Circuit 380 kV Overhead Transmission Line

被引:0
|
作者
Alshehri, Jaber [1 ]
Alshalawi, Abdulaziz [1 ,2 ]
Khalid, Muhammad [1 ,3 ]
机构
[1] King Fahd Univ Petr & Minerals KFUPM, Elect Engn Dept, Dhahran 31261, Saudi Arabia
[2] Saudi Aramco, Tech Support Dept, Ras Tanura 32819, Saudi Arabia
[3] KA CARE Energy Res & Innovat Ctr, Dhahran 31261, Saudi Arabia
关键词
Charge simulation method (CSM); electric field computation; HVAC overhead transmission lines;
D O I
10.1109/icrera47325.2019.8996514
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In today's world, a growing concern among power utilities' workers regarding the possible health hazards associated with the exposure to the electric field of the HVAC overhead transmission lines. Hence, this paper aims to find the electric field distribution under a 380 kV double circuit overhead transmission line. Each phase has four bundles and arranged in a vertical configuration. The HVAC transmission line is modeled in MATLAB based on actual data for a standard 380 kV overhead transmission line of the Saudi National Grid (NG). Using the charge simulation method (CSM), the electric field exposure level has been computed at three distinct levels under the transmission line. These levels are ground level, head level, and close Maintenance level. The electric field profile for each scenario has been plotted. Finally, the simulation results are compared with the maximum allowable exposure limits defined by three different international standards.
引用
收藏
页码:377 / 380
页数:4
相关论文
共 50 条
  • [1] Electric Field Calculation of Double Circuit Compact Overhead Transmission Line on Same 550kV Towers
    Li, Shizuo
    Lu, Huajun
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 237 - +
  • [2] Mitigation of magnetic field under double-circuit overhead transmission line
    Gouda, Osama Elsayed
    El Dein, Adel Z.
    Telkomnika - Indonesian Journal of Electrical Engineering, 2012, 10 (08): : 2272 - 2284
  • [3] ANALYSIS OF ELECTRIC FIELD IN 330 kV OVERHEAD TRANSMISSION LINE
    Deltuva, Ramunas
    Virbalis, Juozapas Arvydas
    Zebrauskas, Stasys
    ELECTRICAL AND CONTROL TECHNOLOGIES, 2011, : 255 - 259
  • [4] Electric Field Computation and Optimization of Composite Tower in 330 kV Double Circuit Transmission Lines
    Wang, Qingyu
    Peng, Zongren
    Yang, Xi
    Li, Naiyi
    Wang, Jialong
    Liao, Jintao
    2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 283 - 286
  • [5] Double Circuit 110 kV Overhead Line Magnetic Field Analysis
    Molnar-Matei, Florin
    Andea, Petru
    Pana, Adrian
    Teslovan, Razvan
    2012 16TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE (MELECON), 2012, : 780 - 783
  • [6] 380 kv Overhead Line Construction.
    Blumer, Roland
    1600, (36): : 3 - 4
  • [7] A Finite-Element Approach for Electric Field Computation at the Surface of Overhead Transmission Line Conductors
    Farah, Arthur A. M.
    Afonso, Marcio M.
    Vasconcelos, Joao A.
    Schroeder, Marco A. O.
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (03)
  • [8] Mitigation of Magnetic Field under Egyptian 500kV Overhead Transmission Line
    El Dein, Adel Z.
    WORLD CONGRESS ON ENGINEERING, WCE 2010, VOL II, 2010, : 956 - 961
  • [9] Computation of the electric field in the vicinity of overhead power line towers
    Modric, Tonci
    Vujevic, Slavko
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 135 : 68 - 76
  • [10] COMPUTATION TECHNIQUES FOR EVALUATING THE ELECTRIC-FIELD EFFECTS OF SINGLE AND DOUBLE CIRCUIT HVAC OVERHEAD LINES
    SALAMA, MH
    SAFAR, Y
    SAIED, M
    JOURNAL OF THE UNIVERSITY OF KUWAIT-SCIENCE, 1986, 13 (01): : 77 - 91