Time Evolution of Deformation in a Human Cartilage Under Cyclic Loading

被引:50
作者
Zhang, Lihai [1 ]
Miramini, Saeed [1 ]
Smith, David W. [2 ]
Gardiner, Bruce S. [2 ]
Grodzinsky, Alan J. [3 ,4 ,5 ,6 ]
机构
[1] Univ Melbourne, Dept Infrastruct Engn, Melbourne, Vic 3010, Australia
[2] Univ Western Australia, Fac Engn Comp & Math, Crawley, WA 6009, Australia
[3] MIT, Ctr Biomed Engn, Cambridge, MA 02139 USA
[4] MIT, Dept Biol Engn, Cambridge, MA 02139 USA
[5] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[6] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
基金
英国医学研究理事会;
关键词
Cartilage; Aggrecan; Computational modelling; Large deformation; Exudation strain; Compressive stiffness; Permeability; ANISOTROPIC HYDRAULIC PERMEABILITY; FINITE-ELEMENT MODEL; ARTICULAR-CARTILAGE; MECHANICAL-PROPERTIES; SOLUTE TRANSPORT; COMPRESSION; CHONDROCYTE; CONSOLIDATION; BIOSYNTHESIS; FORMULATION;
D O I
10.1007/s10439-014-1164-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent imaging has revealed that in vivo contact deformations of human knee cartilage under physiological loadings are surprisingly large-typically on the order of 10%, but up to 20 or 30% of tibiofemora cartilage thickness depending on loading conditions. In this paper we develop a biphasic, large deformation, non-linear poroelastic model of cartilage that can accurately represent the time dependence and magnitude of cyclic cartilage deformations in vivo. The model takes into account cartilage tension-compression nonlinearity and a new constitutive relation in which the compressive stiffness and hydraulic permeability of the cartilage adjusts in response to the strain-dependent aggrecan concentration. The model predictions are validated using experimental test results on osteochondral plugs obtained from human cadavers. We find that model parameters can be optimised to give an excellent fit to the experimental data. Using typical hydraulic conductivity and stiffness parameters for healthy cartilage, we find that the experimentally observed transient and steady state tissue deformations under cyclic loading and unloading can be reproduced by the model. Steady state tissue deformations are shown to cycle between 10% (exudation strain) and 20% (total strain) in response to the cyclic test loads. At steady-state cyclic loading, the pore fluid exuded from the tissue is exactly equal to the pore fluid imbibed by the tissue during each load cycle.
引用
收藏
页码:1166 / 1177
页数:12
相关论文
共 60 条
[41]   Anisotropic hydraulic permeability in compressed articular cartilage [J].
Reynaud, B ;
Quinn, TM .
JOURNAL OF BIOMECHANICS, 2006, 39 (01) :131-137
[42]   Age-related changes in the composition and mechanical properties of human nasal cartilage [J].
Rotter, N ;
Tobias, G ;
Lebl, M ;
Roy, AK ;
Hansen, MC ;
Vacanti, CA ;
Bonassar, LJ .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2002, 403 (01) :132-140
[43]   BIOSYNTHETIC RESPONSE OF CARTILAGE EXPLANTS TO DYNAMIC COMPRESSION [J].
SAH, RLY ;
KIM, YJ ;
DOONG, JYH ;
GRODZINSKY, AJ ;
PLAAS, AHK ;
SANDY, JD .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (05) :619-636
[44]   Altered mechanics of cartilage with osteoarthritis: human osteoarthritis and an experimental model of joint degeneration [J].
Setton, LA ;
Elliott, DM ;
Mow, VC .
OSTEOARTHRITIS AND CARTILAGE, 1999, 7 (01) :2-14
[45]   Computational model for the analysis of cartilage and cartilage tissue constructs [J].
Smith, David W. ;
Gardiner, Bruce S. ;
Davidson, John B. ;
Grodzinsky, Alan J. .
JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2016, 10 (04) :334-347
[46]   A conewise linear elasticity mixture model for the analysis of tension-compression nonlinearity in articular cartilage [J].
Soltz, MA ;
Ateshian, GA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (06) :576-586
[47]   FORMULATION AND EVALUATION OF A FINITE-ELEMENT MODEL FOR THE BIPHASIC MODEL OF HYDRATED SOFT-TISSUES [J].
SPILKER, RL ;
SUH, JK .
COMPUTERS & STRUCTURES, 1990, 35 (04) :425-439
[48]  
Sun DN, 1999, INT J NUMER METH ENG, V45, P1375, DOI 10.1002/(SICI)1097-0207(19990810)45:10<1375::AID-NME635>3.0.CO
[49]  
2-7
[50]   Comparison of biomechanical and biochemical properties of cartilage from human knee and ankle pairs [J].
Treppo, S ;
Koepp, H ;
Quan, EC ;
Cole, AA ;
Kuettner, KE ;
Grodzinsky, AJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (05) :739-748