Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists

被引:14
作者
Farah, J. [1 ]
Struelens, L. [2 ]
Auvinen, A. [3 ]
Jacob, S. [1 ]
Koukorava, C. [4 ]
Schnelzer, M. [5 ]
Vanhavere, F. [2 ]
Clairand, I. [1 ]
机构
[1] Inst Radioprotect & Surete Nucl IRSN PRP HOM SDE, Lab Dosimetrie Rayonnements Ionisants, F-92262 Fontenay Aux Roses, France
[2] Belgian Nucl Res Ctr, Dept Radiat Protect Dosimetry & Calibrat, BE-2400 Mol, Belgium
[3] Radiat & Nucl Safety Author, Res & Environm Surveillance Dept, Helsinki 00881, Finland
[4] Greek Atom Energy Commiss, Div Licensing & Inspect, Athens 15310, Greece
[5] Fed Off Radiat Protect, Radiat Epidemiol Unit, D-85764 Oberschleissheim, Germany
关键词
RADIOLOGY; RADIATION; EXPOSURE;
D O I
10.1093/rpd/ncu315
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose.
引用
收藏
页码:84 / 88
页数:5
相关论文
共 12 条
[1]  
[Anonymous], 2012, ANN ICRP, V41
[2]   Risk of cataract after exposure to low doses of ionizing radiation: A 20-year prospective cohort study among US radiologic technologists [J].
Chodick, Gabriel ;
Bekiroglu, Nural ;
Hauptmann, Michael ;
Alexander, Bruce H. ;
Freedman, D. Michal ;
Doody, Michele Morin ;
Cheung, Li C. ;
Simon, Steven L. ;
Weinstock, Robert M. ;
Bouville, Andre ;
Sigurdson, Alice J. .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2008, 168 (06) :620-631
[3]   Unprotected Operator Eye Lens Doses in Oncologic Interventional Radiology Are Clinically Significant: Estimation from Patient Kerma-area-product Data [J].
Dauer, Lawrence T. ;
Thornton, Raymond H. ;
Solomon, Stephen B. ;
St Germain, Jean .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (12) :1859-1861
[4]   Dosimetry Approach for a Retrospective Epidemiological Study On Eye Lens Dose to Interventional Cardiologists and the Occurrence of Radiation-Induced Lens Opacities [J].
Farah, J. ;
Struelens, L. ;
Jacob, S. ;
Schnelzer, M. ;
Auvinen, A. ;
Vanhavere, F. ;
Clairand, I. .
MEDICAL PHYSICS, 2013, 40 (06)
[5]   A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists [J].
Farah, J. ;
Struelens, L. ;
Dabin, J. ;
Koukorava, C. ;
Donadille, L. ;
Jacob, S. ;
Schnelzer, M. ;
Auvinen, A. ;
Vanhavere, F. ;
Clairand, I. .
RADIATION PROTECTION DOSIMETRY, 2013, 157 (04) :561-569
[6]   Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses [J].
Jacob, Sophie ;
Donadille, Laurent ;
Maccia, Carlo ;
Bar, Olivier ;
Boveda, Serge ;
Laurier, Dominique ;
Bernier, Marie-Odile .
RADIATION PROTECTION DOSIMETRY, 2013, 153 (03) :282-293
[7]   Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses [J].
Koukorava, C. ;
Farah, J. ;
Struelens, L. ;
Clairand, I. ;
Donadille, L. ;
Vanhavere, F. ;
Dimitriou, P. .
JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (03) :509-528
[8]   Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist [J].
Lie, Oydis Ostbye ;
Paulsen, Gudrun Uthaug ;
Wohni, Tor .
RADIATION PROTECTION DOSIMETRY, 2008, 132 (03) :313-318
[9]   Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology [J].
Miller, Donald L. ;
Vano, Eliseo ;
Bartal, Gabriel ;
Balter, Stephen ;
Dixon, Robert ;
Padovani, Renato ;
Schueler, Beth ;
Cardella, John F. ;
de Baere, Thierry .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (02) :230-239
[10]   Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project [J].
Vanhavere, F. ;
Carinou, E. ;
Domienik, J. ;
Donadille, L. ;
Ginjaume, M. ;
Gualdrini, G. ;
Koukorava, C. ;
Krim, S. ;
Nikodemova, D. ;
Ruiz-Lopez, N. ;
Sans-Merce, M. ;
Struelens, L. .
RADIATION MEASUREMENTS, 2011, 46 (11) :1243-1247