Microfabrication-based isothermal titration calorimetry using a combined in-mixing and post-mixing titration approach

被引:6
作者
Feng, Xiangsong [1 ,2 ]
Jia, Yuan [1 ,3 ]
Jiang, Hongyuan [2 ]
Lin, Qiao [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] Harbin Inst Technol, Sch Mechatron Engn, Harbin 150001, Heilongjiang, Peoples R China
[3] Southeast Univ, Sch Mech Engn, Nanjing 211189, Jiangsu, Peoples R China
关键词
CHEMICAL APPLICATIONS; SENSOR; BIOMOLECULES; BIOSENSORS; CONSTANTS;
D O I
10.1039/c8ay00402a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Advances in microfabrication technology can enable innovative took for isothermal titration calorimetry (ITC), which enables direct, label-free determination of thermodynamic parameters of reaction systems. Currently existing microfabricated ITC devices, however, either do not yet allow quantitative thermodynamic characterization, or are not well suited to ITC characterization of fast chemical reactions. Aiming to address these limitations, we present a microfabrication-based ITC approach that uses a combined in-mixing and post-mixing titration approach for accurate characterization of thermodynamic parameters. By accounting for reaction heat produced both during and after the reagent mixing process, accurate, quantitative ITC measurements are achieved. The ITC device design in this approach features a pair of three-dimensional self-crossing channels that serve both as micromixers and reaction cells. A bismuth-antimony thermopile whose hot and cold junctions are aligned to the centers of the crossing channels, is used for reaction heat detection. The microfabricated ITC device has a low limit of detection of 45 nW, and a short thermal response time of 800 ms. The utility of the device has been demonstrated with quantitative ITC measurements of the model chemical reaction system of 18-Crown-6 and barium chloride. The thermodynamic parameters of the reaction system, including the stoichiometry, equilibrium binding constant, and enthalpy change were obtained and found to be in agreement with widely accepted values in the literature.
引用
收藏
页码:4665 / 4670
页数:7
相关论文
共 33 条
[1]   Comparative advantages of mechanical biosensors [J].
Arlett, J. L. ;
Myers, E. B. ;
Roukes, M. L. .
NATURE NANOTECHNOLOGY, 2011, 6 (04) :203-215
[2]   Highly sensitive thermopile heat power sensor for micro-fluid calorimetry of biochemical processes [J].
Baier, V ;
Födisch, R ;
Ihring, A ;
Kessler, E ;
Lerchner, J ;
Wolf, G ;
Köhler, JM ;
Nietzsch, M ;
Krügel, M .
SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 :354-359
[3]  
Bin Wang Y. J., 2012, 16 INT C MIN SYST CH, P195
[4]   A novel aptasensor for electrochemical detection of ractopamine, clenbuterol, salbutamol, phenylethanolamine and procaterol [J].
Chen, Dan ;
Yang, Min ;
Zheng, Nianjue ;
Xie, Ni ;
Liu, Daling ;
Xie, Chunfang ;
Yao, Dongsheng .
BIOSENSORS & BIOELECTRONICS, 2016, 80 :525-531
[5]   Thermodynamic studies of lectin-carbohydrate interactions by isothermal titration calorimetry [J].
Dam, TK ;
Brewer, CF .
CHEMICAL REVIEWS, 2002, 102 (02) :387-429
[6]   Effect of the crossing-structure sequence on mixing performance within three-dimensional micromixers [J].
Feng, Xiangsong ;
Ren, Yukun ;
Jiang, Hongyuan .
BIOMICROFLUIDICS, 2014, 8 (03)
[7]   An effective splitting-and-recombination micromixer with self-rotated contact surface for wide Reynolds number range applications [J].
Feng, Xiangsong ;
Ren, Yukun ;
Jiang, Hongyuan .
BIOMICROFLUIDICS, 2013, 7 (05)
[8]   ISOTHERMAL TITRATION CALORIMETRY [J].
FREIRE, E ;
MAYORGA, OL ;
STRAUME, M .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :A950-A959
[9]   Calorimetric Biosensing System for Quantification of Urinary Creatinine [J].
Gaddes, David ;
Reeves, William Brian ;
Tadigadapa, Srinivas .
ACS SENSORS, 2017, 2 (06) :796-802
[10]   Thermal analysis of chemical reaction with a continuous microfluidic calorimeter [J].
Hany, Cindy ;
Lebrun, Helene ;
Pradere, Christophe ;
Toutain, Jean ;
Batsale, Jean-Christophe .
CHEMICAL ENGINEERING JOURNAL, 2010, 160 (03) :814-822