Shake-Table Tests of a Pile-Supported Low-Rise Reinforced Concrete Building Designed to Japanese Building Standards

被引:3
作者
Pan, Haoran [1 ]
Yeow, Trevor Z. [2 ]
Kusunoki, Koichi [3 ]
Yamazoe, Masatoshi [4 ]
Sako, Yuji [4 ]
机构
[1] Guangzhou Univ, Res Ctr Wind Engn & Engn Vibrat, Guangzhou Higher Educ Mega Ctr, 230 Wai Huan Xi Rd, Guangzhou 510006, Peoples R China
[2] Univ Tokyo, Earthquake Res Inst, Bunkyo Ku, Room 1-511,1-1-1 Yayoi, Tokyo 1130032, Japan
[3] Univ Tokyo, Earthquake Res Inst, Bunkyo Ku, Room 1-402,1-1-1 Yayoi, Tokyo 1130032, Japan
[4] Kobori Res Complex Inc, Minato Ku, 6-5-30 Akasaka, Tokyo 1078502, Japan
关键词
MODEL;
D O I
10.1061/(ASCE)ST.1943-541X.0003391
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In Japanese engineering practice, pile foundations are designed to lower base shear demands below that considered in the superstructure's design. In recent earthquakes, such buildings incurred significant pile damage even in cases where the superstructure only had minor damage. This study looks to replicate this failure mechanism via large-scale shake-table tests of a pile-supported building designed following Japanese practice, compare its performance against a fixed-base case, and identify issues with such buildings. The specimen was a 40%-scaled 3-story reinforced concrete frame building supported on weak piles buried in soil. After completing shake-table testing of the pile-supported specimen, the specimen's foundation was fixed directly to the soil tank to mimic a fixed-base condition, and further excitations were applied. For the pile-supported case, the piles underwent drift ratio demands of up to 14% and suffered local collapse failure at 1.0-1.5 times the design shaking intensity, whereas the superstructure only had a drift ratio of 0.17% and minor damage. These observations were consistent with postearthquake damage assessments, demonstrating that the shake-table tests were able to replicate realistic failure mechanisms. For the fixed-base case, the superstructure was able to withstand demands equivalent to 1.7-2.5 times the Japanese design spectra before reaching 2.0% drift and did not exhibit any strength degradation. Based on these results, buildings with weak piles will likely suffer significant failure at smaller intensity events than that which the superstructure would have been able to withstand. Furthermore, the lack of superstructure damage for such cases may lead to significant pile failure being unidentified during postearthquake inspections, resulting in unsafe buildings being occupied. (C) 2022 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 41 条
[1]  
[Anonymous], 1996, P 4 CALTR SEISM RES
[2]  
Architectural Institute of Japan (AIJ), 2012, PREL REC REP 2011 TO
[3]  
BCJ (Building Center of Japan), 2016, BUILD STAND LAW JAP
[4]   Seismic soil-pile-structure interaction experiments and analyses [J].
Boulanger, RW ;
Curras, CJ ;
Kutter, BL ;
Wilson, DW ;
Abghari, A .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 1999, 125 (09) :750-759
[5]   Nonlinear seismic soil-pile-structure interactions: Shaking table tests and FEM analyses [J].
Chau, K. T. ;
Shen, C. Y. ;
Guo, X. .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2009, 29 (02) :300-310
[6]   Seismic Resistance Capacity of High-Rise Buildings Subjected to Long-Period Ground Motions: E-Defense Shaking Table Test [J].
Chung, Yu-Lin ;
Nagae, Takuya ;
Hitaka, Toko ;
Nakashima, Masayoshi .
JOURNAL OF STRUCTURAL ENGINEERING, 2010, 136 (06) :637-644
[7]  
Dehghanpoor Sichani A., 2017, PROC PBD 3 EARTHQUAK, VIII
[8]   Model studies of boundary effect on dynamic soil response [J].
Dou, H ;
Byrne, PM .
CANADIAN GEOTECHNICAL JOURNAL, 1997, 34 (03) :460-465
[9]   Soil-pile-structure interaction: experimental outcomes from shaking table tests [J].
Durante, Maria Giovanna ;
Di Sarno, Luigi ;
Mylonakis, George ;
Taylor, Colin A. ;
Simonelli, Armando Lucio .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (07) :1041-1061
[10]   A study of piles during earthquakes: Issues of design and analysis [J].
Finn, W. D. Liam .
BULLETIN OF EARTHQUAKE ENGINEERING, 2005, 3 (02) :141-234