Acoustic method for synchronization of magnetic resonance imaging (MRI)

被引:32
作者
Frauenrath, Tobias [1 ,2 ]
Niendorf, Thoralf [2 ]
Kob, Malte [1 ,2 ]
机构
[1] Rhein Westfal TH Aachen, Dept Phoniatr Pedaudiol & Commun Disorders, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Div Expt MR Imaging, D-52074 Aachen, Germany
关键词
D O I
10.3813/AAA.918017
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Magnetic Resonance Imaging ( MRI) of moving organs requires synchronization with physiological motion or flow, which dictate the viable window for data acquisition. To meet this challenge, this study proposes an acoustic gating device ( ACG) that employs acquisition and processing of acoustic signals for synchronization while providing MRI compatibility, immunity to interferences with electro-magnetic and acoustic fields and suitability for MRI at high magnetic field strengths. The applicability and robustness of the acoustic gating approach is examined in a pilot study, where it substitutes conventional ECG-gating for cardiovascular MR. The merits and limitations of the ACG approach are discussed. Implications for MR imaging in the presence of physiological motion are considered including synchronization with other structure-or motion borne sounds.
引用
收藏
页码:148 / 155
页数:8
相关论文
共 23 条
[11]   Short breath-hold, volumetric coronary MR angiography employing steady-state free precession in conjunction with parallel imaging [J].
Niendorf, T ;
Saranathan, M ;
Lingamneni, A ;
Pedrosa, I ;
Spencer, M ;
Cline, H ;
Foo, TKF ;
Rofsky, NM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) :885-894
[12]   MR imaging in abdominal emergencies [J].
Pedrosa, I ;
Rofsky, NM .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2003, 41 (06) :1243-+
[13]   Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Pane report [J].
Pennell, DJ ;
Sechtem, UP ;
Higgins, CB ;
Manning, WJ ;
Pohost, GM ;
Rademakers, FE ;
van Rossum, AC ;
Shaw, LJ ;
Yucel, EK .
EUROPEAN HEART JOURNAL, 2004, 25 (21) :1940-1965
[14]   Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating [J].
Plein, S ;
Jones, TR ;
Ridgway, JP ;
Sivananthan, MU .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) :505-512
[15]   Expanding role of MR angiography in clinical practice [J].
Prince, MR ;
Meaney, JFM .
EUROPEAN RADIOLOGY, 2006, 16 :B3-B8
[16]  
RANGAYYAN RM, 1988, CRIT REV BIOMED ENG, V15, P211
[17]  
Shimada Yasuhiro, 2002, Nihon Hoshasen Gijutsu Gakkai Zasshi, V58, P1592
[18]   Free breathing 3D balanced FFE coronary magnetic resonance angiography with prolonged cardiac acquisition windows and intra-RR motion correction [J].
Stehning, C ;
Börnert, P ;
Nehrke, K ;
Dössel, O .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :719-723
[19]   Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography [J].
Stuber, M ;
Botnar, RM ;
Danias, PG ;
Sodickson, DK ;
Kissinger, KV ;
Van Cauteren, M ;
De Becker, J ;
Manning, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) :524-531
[20]   Preliminary report on in vivo coronary MRA at 3 Tesla in humans [J].
Stuber, M ;
Botnar, RM ;
Fischer, SE ;
Lamerichs, R ;
Smink, J ;
Harvey, P ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :425-429