摘要
Magnetic Resonance Imaging ( MRI) of moving organs requires synchronization with physiological motion or flow, which dictate the viable window for data acquisition. To meet this challenge, this study proposes an acoustic gating device ( ACG) that employs acquisition and processing of acoustic signals for synchronization while providing MRI compatibility, immunity to interferences with electro-magnetic and acoustic fields and suitability for MRI at high magnetic field strengths. The applicability and robustness of the acoustic gating approach is examined in a pilot study, where it substitutes conventional ECG-gating for cardiovascular MR. The merits and limitations of the ACG approach are discussed. Implications for MR imaging in the presence of physiological motion are considered including synchronization with other structure-or motion borne sounds.
引用
收藏
页码:148 / 155
页数:8
相关论文
共 23 条
[1]  
Chia JM, 2000, J MAGN RESON IMAGING, V12, P678, DOI 10.1002/1522-2586(200011)12:5<678::AID-JMRI4>3.0.CO
[2]  
2-5
[3]   Using cardiac phase to order reconstruction [CAPTOR]: A method to improve diastolic images [J].
Feinstein, JA ;
Epstein, FH ;
Arai, AE ;
Foo, TKF ;
Hartley, MR ;
Balaban, RS ;
Wolff, SD .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :794-798
[4]  
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
[5]  
2-9
[6]   Quantitative analysis of ECG-gated high-resolution contrast-enhanced MR angiography of the thoracic aorta [J].
Groves, Elliott M. ;
Bireley, William ;
Dill, Karin ;
Carroll, Timothy J. ;
Carr, James C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) :522-528
[7]  
Honda K, 2004, IEICE T INF SYST, VE87D, P1050
[8]  
KOB M, 2006, P 5 INT C VOIC PHYS, P45
[9]   Retrospective motion correction protocol for high-resolution anatomical MRI [J].
Kochunov, Peter ;
Lancaster, Jack L. ;
Glahn, David C. ;
Purdy, David ;
Laird, Angela R. ;
Gao, Feng ;
Fox, Peter .
HUMAN BRAIN MAPPING, 2006, 27 (12) :957-962
[10]  
Merkle Elmar M, 2006, Magn Reson Imaging Clin N Am, V14, P17, DOI 10.1016/j.mric.2005.12.001