Comparative analysis of cadmium-zincum-telluride cameras dedicated to myocardial perfusion SPECT: A phantom study

被引:17
作者
Zoccarato, Orazio [1 ,2 ]
Lizio, Domenico [3 ,4 ]
Savi, Annarita [5 ]
Indovina, Luca [6 ]
Scabbio, Camilla [7 ,8 ]
Leva, Lucia [3 ,4 ]
del Sole, Angelo [7 ,8 ]
Marcassa, Claudio [1 ,2 ,4 ]
Matheoud, Roberta [3 ,4 ]
Lecchi, Michela [7 ,8 ]
Brambilla, Marco [3 ,9 ]
机构
[1] S Maugeri Fdn, IRCCS, Sci Inst Veruno, Nucl Med Unit, Veruno, NO, Italy
[2] S Maugeri Fdn, IRCCS, Sci Inst Veruno, Dept Cardiol, Veruno, NO, Italy
[3] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[4] Univ Hosp Maggiore della Carita, Dept Nucl Med, Novara, Italy
[5] Hosp San Raffaele, Dept Nucl Med, Milan, Italy
[6] Polyclin Agostino Gemelli, Dept Med Phys, Rome, Italy
[7] Univ Milan, Dept Hlth Sci, Milan, Italy
[8] San Paolo Hosp, Nucl Med Unit, Milan, Italy
[9] Univ Hosp Novara, Dept Med Phys, Novara, Italy
关键词
SPECT; Cardiac; Cadmium-zincum-telluride; ACQUISITION; SYSTEM; TIME;
D O I
10.1007/s12350-015-0203-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. This investigation used image data generated by an anthropomorphic phantom with a cardiac insert for a comparison between two solid state cameras: D-SPECT and D530c. Methods. For each camera, two sets (with and without a simulated transmural defect (TD)) of scans were acquired starting from the in vivo standard count statistics in the left ventricle (LV). Other two acquisitions corresponding to 150% and 50% of the reference count statistics were acquired. Five performance indices related to spatial resolution, contrast, and contrast-to-noise ratio (CNR) were analyzed. Results. D-SPECT showed a lower LV wall thickness and an inferior sharpness than D530c. No significant differences were found in terms of contrast between LV wall and the inner cavity, TD contrast or CNR. No significant differences were observed in CNR when moving from the reference level of count statistics down to 50% or up to 150% of the counts acquired on the LV. Conclusions. Our results show that D-SPECT and D530c have different performances. The lack of differences in the image performance indices along the range of count statistics explored, indicates that there is the possibility for a further reduction in the injected activity and/or the acquisition time, for both systems.
引用
收藏
页码:885 / 893
页数:9
相关论文
共 17 条
[1]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[2]   Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation [J].
Buechel, Ronny R. ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Treyer, Valerie ;
Valenta, Ines ;
von Schulthess, Patrick ;
Nkoulou, Rene ;
Wyss, Christophe A. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (04) :773-778
[3]   IQ SPECT Allows a Significant Reduction in Administered Dose and Acquisition Time for Myocardial Perfusion Imaging: Evidence from a Phantom Study [J].
Caobelli, Federico ;
Kaiser, Stefano Ren ;
Thackeray, James T. ;
Bengel, Frank M. ;
Chieregato, Matteo ;
Soffientini, Alberto ;
Pizzocaro, Claudio ;
Savelli, Giordano ;
Galelli, Marco ;
Guerra, Ugo Paolo .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (12) :2064-2070
[4]   Comparison of high efficiency CZT SPECT MPI to coronary angiography [J].
Duvall, W. Lane ;
Sweeny, Joseph M. ;
Croft, Lori B. ;
Barghash, Maya H. ;
Kulkarni, Nitin K. ;
Guma, Krista A. ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (04) :595-604
[5]   Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology [J].
Erlandsson, Kjell ;
Kacperski, Krzysztof ;
van Gramberg, Dean ;
Hutton, Brian F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :2635-2649
[6]   Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras [J].
Esteves, Fabio P. ;
Raggi, Paolo ;
Folks, Russell D. ;
Keidar, Zohar ;
Askew, J. Wells ;
Rispler, Shmuel ;
O'Connor, Michael K. ;
Verdes, Liudmilla ;
Garcia, Ernest V. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (06) :927-934
[7]   A Novel High-Sensitivity Rapid-Acquisition Single-Photon Cardiac Imaging Camera [J].
Gambhir, Sanjiv S. ;
Berman, Daniel S. ;
Ziffer, Jack ;
Nagler, Michael ;
Sandler, Martin ;
Patton, Jim ;
Hutton, Brian ;
Sharir, Tali ;
Ben Haim, Shlomo ;
Ben Haim, Simona .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) :635-643
[8]   Nuclear Myocardial Perfusion Imaging with a Cadmium-Zinc-Telluride Detector Technique: Optimized Protocol for Scan Time Reduction [J].
Herzog, Bernhard A. ;
Buechel, Ronny R. ;
Katz, Ruth ;
Brueckner, Michael ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Valenta, Ines ;
Gaemperli, Oliver ;
Treyer, Valerie ;
Kaufmann, Philipp A. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (01) :46-51
[9]   Compared Performance of High-Sensitivity Cameras Dedicated to Myocardial Perfusion SPECT: A Comprehensive Analysis of Phantom and Human Images [J].
Imbert, Laetitia ;
Poussier, Sylvain ;
Franken, Philippe R. ;
Songy, Bernard ;
Verger, Antoine ;
Morel, Olivier ;
Wolf, Didier ;
Noel, Alain ;
Karcher, Gilles ;
Marie, Pierre-Yves .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (12) :1897-1903
[10]   A performance comparison of novel cadmium-zinc-telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuation [J].
Liu, Chia-Ju ;
Cheng, Ju-Shin ;
Chen, Yi-Chieh ;
Huang, Yih-Hwen ;
Yen, Ruoh-Fang .
ANNALS OF NUCLEAR MEDICINE, 2015, 29 (04) :342-350